Elevated temperature electrochemical studies of preoxidized nickel electrodes in the presence of sulfide

The electrochemical response of a preoxidized nickel electrode to increasing additions of sulfide has been examined over temperature range from 25 to 70°C. In the presence of sulfide a stripping like response was observed at all temperatures. The results detailed show that as the temperature is incr...

Full description

Bibliographic Details
Main Authors: Streeter, I, Giovanelli, D, Wildgoose, G, Lawrence, N, Jiang, L, Jones, T, Compton, R
Format: Journal article
Language:English
Published: 2004
_version_ 1826281977252151296
author Streeter, I
Giovanelli, D
Wildgoose, G
Lawrence, N
Jiang, L
Jones, T
Compton, R
author_facet Streeter, I
Giovanelli, D
Wildgoose, G
Lawrence, N
Jiang, L
Jones, T
Compton, R
author_sort Streeter, I
collection OXFORD
description The electrochemical response of a preoxidized nickel electrode to increasing additions of sulfide has been examined over temperature range from 25 to 70°C. In the presence of sulfide a stripping like response was observed at all temperatures. The results detailed show that as the temperature is increased the sensitivity increases from 3.4 to 13.5 A M-1 for the determination of sulfide.
first_indexed 2024-03-07T00:36:55Z
format Journal article
id oxford-uuid:81bcc9dd-78ab-4038-aa82-488df8b9f865
institution University of Oxford
language English
last_indexed 2024-03-07T00:36:55Z
publishDate 2004
record_format dspace
spelling oxford-uuid:81bcc9dd-78ab-4038-aa82-488df8b9f8652022-03-26T21:32:16ZElevated temperature electrochemical studies of preoxidized nickel electrodes in the presence of sulfideJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:81bcc9dd-78ab-4038-aa82-488df8b9f865EnglishSymplectic Elements at Oxford2004Streeter, IGiovanelli, DWildgoose, GLawrence, NJiang, LJones, TCompton, RThe electrochemical response of a preoxidized nickel electrode to increasing additions of sulfide has been examined over temperature range from 25 to 70°C. In the presence of sulfide a stripping like response was observed at all temperatures. The results detailed show that as the temperature is increased the sensitivity increases from 3.4 to 13.5 A M-1 for the determination of sulfide.
spellingShingle Streeter, I
Giovanelli, D
Wildgoose, G
Lawrence, N
Jiang, L
Jones, T
Compton, R
Elevated temperature electrochemical studies of preoxidized nickel electrodes in the presence of sulfide
title Elevated temperature electrochemical studies of preoxidized nickel electrodes in the presence of sulfide
title_full Elevated temperature electrochemical studies of preoxidized nickel electrodes in the presence of sulfide
title_fullStr Elevated temperature electrochemical studies of preoxidized nickel electrodes in the presence of sulfide
title_full_unstemmed Elevated temperature electrochemical studies of preoxidized nickel electrodes in the presence of sulfide
title_short Elevated temperature electrochemical studies of preoxidized nickel electrodes in the presence of sulfide
title_sort elevated temperature electrochemical studies of preoxidized nickel electrodes in the presence of sulfide
work_keys_str_mv AT streeteri elevatedtemperatureelectrochemicalstudiesofpreoxidizednickelelectrodesinthepresenceofsulfide
AT giovanellid elevatedtemperatureelectrochemicalstudiesofpreoxidizednickelelectrodesinthepresenceofsulfide
AT wildgooseg elevatedtemperatureelectrochemicalstudiesofpreoxidizednickelelectrodesinthepresenceofsulfide
AT lawrencen elevatedtemperatureelectrochemicalstudiesofpreoxidizednickelelectrodesinthepresenceofsulfide
AT jiangl elevatedtemperatureelectrochemicalstudiesofpreoxidizednickelelectrodesinthepresenceofsulfide
AT jonest elevatedtemperatureelectrochemicalstudiesofpreoxidizednickelelectrodesinthepresenceofsulfide
AT comptonr elevatedtemperatureelectrochemicalstudiesofpreoxidizednickelelectrodesinthepresenceofsulfide