Subcutaneous tumor volume measurement in the awake, manually restrained mouse using MRI.

PURPOSE: To describe a combination of techniques using the excellent volumetric capacities of magnetic resonance imaging (MRI) while avoiding anesthesia and maintaining high-throughput capability for tumor volume measurement in the awake mouse. This approach presents an alternative to calipers whic...

Full description

Bibliographic Details
Main Authors: Kersemans, V, Cornelissen, B, Allen, P, Beech, J, Smart, S
Format: Journal article
Language:English
Published: Wiley 2013
_version_ 1797079041760559104
author Kersemans, V
Cornelissen, B
Allen, P
Beech, J
Smart, S
author_facet Kersemans, V
Cornelissen, B
Allen, P
Beech, J
Smart, S
author_sort Kersemans, V
collection OXFORD
description PURPOSE: To describe a combination of techniques using the excellent volumetric capacities of magnetic resonance imaging (MRI) while avoiding anesthesia and maintaining high-throughput capability for tumor volume measurement in the awake mouse. This approach presents an alternative to calipers which, although cheap, fast, and easy to use, introduce many biases for tumor volume estimation. MATERIALS AND METHODS: The murine CaNT subcutaneous xenograft model was used. A quiet and modestly T2-weighted spin-echo scan was acquired at 4.7T (TE = 15 msec, TR = 1100 msec, 0.5 mm isotropic resolution) while the awake mouse was held by hand in the magnet. This method was compared to standard MR in the anesthetized mouse and caliper measurements. RESULTS: The combination of techniques used allows rapid, accurate, and reproducible measurement of subcutaneous tumor volumes in awake mice. It is less sensitive to both intra- and interoperator-derived biases and avoids confounds from the compliance of the fat and skin around the tumor, as well as from the tumor itself. Moreover, the data remain available for retrieval and scrutiny and reanalysis. CONCLUSION: Rapid, accurate, and precise tumor volumetry can be performed in the awake mouse by handheld positioned MR.
first_indexed 2024-03-07T00:39:59Z
format Journal article
id oxford-uuid:82b70d7c-b34e-49ec-acaa-df4c9346f522
institution University of Oxford
language English
last_indexed 2024-03-07T00:39:59Z
publishDate 2013
publisher Wiley
record_format dspace
spelling oxford-uuid:82b70d7c-b34e-49ec-acaa-df4c9346f5222022-03-26T21:39:20ZSubcutaneous tumor volume measurement in the awake, manually restrained mouse using MRI.Journal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:82b70d7c-b34e-49ec-acaa-df4c9346f522EnglishSymplectic Elements at OxfordWiley2013Kersemans, VCornelissen, BAllen, PBeech, JSmart, S PURPOSE: To describe a combination of techniques using the excellent volumetric capacities of magnetic resonance imaging (MRI) while avoiding anesthesia and maintaining high-throughput capability for tumor volume measurement in the awake mouse. This approach presents an alternative to calipers which, although cheap, fast, and easy to use, introduce many biases for tumor volume estimation. MATERIALS AND METHODS: The murine CaNT subcutaneous xenograft model was used. A quiet and modestly T2-weighted spin-echo scan was acquired at 4.7T (TE = 15 msec, TR = 1100 msec, 0.5 mm isotropic resolution) while the awake mouse was held by hand in the magnet. This method was compared to standard MR in the anesthetized mouse and caliper measurements. RESULTS: The combination of techniques used allows rapid, accurate, and reproducible measurement of subcutaneous tumor volumes in awake mice. It is less sensitive to both intra- and interoperator-derived biases and avoids confounds from the compliance of the fat and skin around the tumor, as well as from the tumor itself. Moreover, the data remain available for retrieval and scrutiny and reanalysis. CONCLUSION: Rapid, accurate, and precise tumor volumetry can be performed in the awake mouse by handheld positioned MR.
spellingShingle Kersemans, V
Cornelissen, B
Allen, P
Beech, J
Smart, S
Subcutaneous tumor volume measurement in the awake, manually restrained mouse using MRI.
title Subcutaneous tumor volume measurement in the awake, manually restrained mouse using MRI.
title_full Subcutaneous tumor volume measurement in the awake, manually restrained mouse using MRI.
title_fullStr Subcutaneous tumor volume measurement in the awake, manually restrained mouse using MRI.
title_full_unstemmed Subcutaneous tumor volume measurement in the awake, manually restrained mouse using MRI.
title_short Subcutaneous tumor volume measurement in the awake, manually restrained mouse using MRI.
title_sort subcutaneous tumor volume measurement in the awake manually restrained mouse using mri
work_keys_str_mv AT kersemansv subcutaneoustumorvolumemeasurementintheawakemanuallyrestrainedmouseusingmri
AT cornelissenb subcutaneoustumorvolumemeasurementintheawakemanuallyrestrainedmouseusingmri
AT allenp subcutaneoustumorvolumemeasurementintheawakemanuallyrestrainedmouseusingmri
AT beechj subcutaneoustumorvolumemeasurementintheawakemanuallyrestrainedmouseusingmri
AT smarts subcutaneoustumorvolumemeasurementintheawakemanuallyrestrainedmouseusingmri