Tailoring the size of ultrasound responsive lipid-shelled nanodroplets by varying production parameters and environmental conditions

Liquid perfluorocarbon nanodroplets (NDs) are an attractive alternative to microbubbles (MBs) for ultrasound-mediated therapeutic and diagnostic applications. ND size and size distribution have a strong influence on their behaviour in vivo, including extravasation efficiency, circulation time, and r...

Full description

Bibliographic Details
Main Authors: Ferri, S, Wu, Q, De Grazia, A, Polydorou, A, May, JP, Stride, E, Evans, ND, Carugo, D
Format: Journal article
Language:English
Published: Elsevier 2021
_version_ 1826283251820396544
author Ferri, S
Wu, Q
De Grazia, A
Polydorou, A
May, JP
Stride, E
Evans, ND
Carugo, D
author_facet Ferri, S
Wu, Q
De Grazia, A
Polydorou, A
May, JP
Stride, E
Evans, ND
Carugo, D
author_sort Ferri, S
collection OXFORD
description Liquid perfluorocarbon nanodroplets (NDs) are an attractive alternative to microbubbles (MBs) for ultrasound-mediated therapeutic and diagnostic applications. ND size and size distribution have a strong influence on their behaviour in vivo, including extravasation efficiency, circulation time, and response to ultrasound stimulation. Thus, it is desirable to identify ways to tailor the ND size and size distribution during manufacturing. In this study phospholipid-coated NDs, comprising a perfluoro-n-pentane (PFP) core stabilised by a DSPC/PEG40s (1,2-distearoyl-sn-glycero-3-phosphocholine and polyoxyethylene(40)stearate, 9:1 molar ratio) shell, were produced in phosphate-buffered saline (PBS) by sonication. The effect of the following production-related parameters on ND size was investigated: PFP concentration, power and duration of sonication, and incorporation of a lipophilic fluorescent dye. ND stability was also assessed at both 4 °C and 37 °C. When a sonication pulse of 6 s and 15% duty cycle was employed, increasing the volumetric concentration of PFP from 5% to 15% v/v in PBS resulted in an increase in ND diameter from 215.8 ± 16.8 nm to 408.9 ± 171.2 nm. An increase in the intensity of sonication from 48 to 72 W (with 10% PFP v/v in PBS) led to a decrease in ND size from 354.6 ± 127.2 nm to 315.0 ± 100.5 nm. Increasing the sonication time from 20 s to 40 s (using a pulsed sonication with 30% duty cycle) did not result in a significant change in ND size (in the range 278–314 nm); however, when it was increased to 60 s, the average ND diameter reduced to 249.7 ± 9.7 nm, which also presented a significantly lower standard deviation compared to the other experimental conditions investigated (i.e., 9.7 nm vs. > 49.4 nm). The addition of the fluorescent dye DiI at different molar ratios did not affect the ND size distribution. NDs were stable at 4 °C for up to 6 days and at 37 °C for up to 110 min; however, some evidence of ND-to-MB phase transition was observed after 40 min at 37 °C. Finally, phase transition of NDs into MBs was demonstrated using a tissue-mimicking flow phantom under therapeutic ultrasound exposure conditions (ultrasound frequency: 0.5 MHz, acoustic pressure: 2–4 MPa, and pulse repetition frequency: 100 Hz).
first_indexed 2024-03-07T00:56:06Z
format Journal article
id oxford-uuid:88243dfc-efa4-472b-92e8-6596dcd20068
institution University of Oxford
language English
last_indexed 2024-03-07T00:56:06Z
publishDate 2021
publisher Elsevier
record_format dspace
spelling oxford-uuid:88243dfc-efa4-472b-92e8-6596dcd200682022-03-26T22:15:09ZTailoring the size of ultrasound responsive lipid-shelled nanodroplets by varying production parameters and environmental conditionsJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:88243dfc-efa4-472b-92e8-6596dcd20068EnglishSymplectic ElementsElsevier2021Ferri, SWu, QDe Grazia, APolydorou, AMay, JPStride, EEvans, NDCarugo, DLiquid perfluorocarbon nanodroplets (NDs) are an attractive alternative to microbubbles (MBs) for ultrasound-mediated therapeutic and diagnostic applications. ND size and size distribution have a strong influence on their behaviour in vivo, including extravasation efficiency, circulation time, and response to ultrasound stimulation. Thus, it is desirable to identify ways to tailor the ND size and size distribution during manufacturing. In this study phospholipid-coated NDs, comprising a perfluoro-n-pentane (PFP) core stabilised by a DSPC/PEG40s (1,2-distearoyl-sn-glycero-3-phosphocholine and polyoxyethylene(40)stearate, 9:1 molar ratio) shell, were produced in phosphate-buffered saline (PBS) by sonication. The effect of the following production-related parameters on ND size was investigated: PFP concentration, power and duration of sonication, and incorporation of a lipophilic fluorescent dye. ND stability was also assessed at both 4 °C and 37 °C. When a sonication pulse of 6 s and 15% duty cycle was employed, increasing the volumetric concentration of PFP from 5% to 15% v/v in PBS resulted in an increase in ND diameter from 215.8 ± 16.8 nm to 408.9 ± 171.2 nm. An increase in the intensity of sonication from 48 to 72 W (with 10% PFP v/v in PBS) led to a decrease in ND size from 354.6 ± 127.2 nm to 315.0 ± 100.5 nm. Increasing the sonication time from 20 s to 40 s (using a pulsed sonication with 30% duty cycle) did not result in a significant change in ND size (in the range 278–314 nm); however, when it was increased to 60 s, the average ND diameter reduced to 249.7 ± 9.7 nm, which also presented a significantly lower standard deviation compared to the other experimental conditions investigated (i.e., 9.7 nm vs. > 49.4 nm). The addition of the fluorescent dye DiI at different molar ratios did not affect the ND size distribution. NDs were stable at 4 °C for up to 6 days and at 37 °C for up to 110 min; however, some evidence of ND-to-MB phase transition was observed after 40 min at 37 °C. Finally, phase transition of NDs into MBs was demonstrated using a tissue-mimicking flow phantom under therapeutic ultrasound exposure conditions (ultrasound frequency: 0.5 MHz, acoustic pressure: 2–4 MPa, and pulse repetition frequency: 100 Hz).
spellingShingle Ferri, S
Wu, Q
De Grazia, A
Polydorou, A
May, JP
Stride, E
Evans, ND
Carugo, D
Tailoring the size of ultrasound responsive lipid-shelled nanodroplets by varying production parameters and environmental conditions
title Tailoring the size of ultrasound responsive lipid-shelled nanodroplets by varying production parameters and environmental conditions
title_full Tailoring the size of ultrasound responsive lipid-shelled nanodroplets by varying production parameters and environmental conditions
title_fullStr Tailoring the size of ultrasound responsive lipid-shelled nanodroplets by varying production parameters and environmental conditions
title_full_unstemmed Tailoring the size of ultrasound responsive lipid-shelled nanodroplets by varying production parameters and environmental conditions
title_short Tailoring the size of ultrasound responsive lipid-shelled nanodroplets by varying production parameters and environmental conditions
title_sort tailoring the size of ultrasound responsive lipid shelled nanodroplets by varying production parameters and environmental conditions
work_keys_str_mv AT ferris tailoringthesizeofultrasoundresponsivelipidshellednanodropletsbyvaryingproductionparametersandenvironmentalconditions
AT wuq tailoringthesizeofultrasoundresponsivelipidshellednanodropletsbyvaryingproductionparametersandenvironmentalconditions
AT degraziaa tailoringthesizeofultrasoundresponsivelipidshellednanodropletsbyvaryingproductionparametersandenvironmentalconditions
AT polydoroua tailoringthesizeofultrasoundresponsivelipidshellednanodropletsbyvaryingproductionparametersandenvironmentalconditions
AT mayjp tailoringthesizeofultrasoundresponsivelipidshellednanodropletsbyvaryingproductionparametersandenvironmentalconditions
AT stridee tailoringthesizeofultrasoundresponsivelipidshellednanodropletsbyvaryingproductionparametersandenvironmentalconditions
AT evansnd tailoringthesizeofultrasoundresponsivelipidshellednanodropletsbyvaryingproductionparametersandenvironmentalconditions
AT carugod tailoringthesizeofultrasoundresponsivelipidshellednanodropletsbyvaryingproductionparametersandenvironmentalconditions