Gap-corrected thin-film permittivity and permeability measurement with a broadband coaxial line technique

A technique for measuring the high frequency broadband complex permittivity and permeability of thin films from 50 MHz up to 18 GHz without the need for a reference sample for calibration is presented. A thin film for measurement is wound into a torus and inserted into a coaxial line. As a cons...

Full description

Bibliographic Details
Main Authors: Wang, Y, Hooper, I, Edwards, E, Grant, P
Format: Journal article
Published: IEEE 2016
_version_ 1797080625798184960
author Wang, Y
Hooper, I
Edwards, E
Grant, P
author_facet Wang, Y
Hooper, I
Edwards, E
Grant, P
author_sort Wang, Y
collection OXFORD
description A technique for measuring the high frequency broadband complex permittivity and permeability of thin films from 50 MHz up to 18 GHz without the need for a reference sample for calibration is presented. A thin film for measurement is wound into a torus and inserted into a coaxial line. As a consequence, this method is suitable for measuring flexible selfsupported films and coatings fabricated on flexible substrates. With the torus axis of symmetry along the coaxial direction, the electromagnetic properties of the wound torus can be deduced from the perturbed reflection and transmission coefficients of an incident wave. However, when permittivity and permeability are then obtained, there is a contribution from the effect of air gaps that cannot be avoided between layers of the wound film, which results in an underestimation of the measured permittivity and permeability. An analytical air gap correction model has been developed to account for this air gap effect that is then validated by experiments and shown also to be consistent with finite element simulations. The relative effects of film thickness and air gap on a range of measured permittivity and permeability have been also elucidated.
first_indexed 2024-03-07T01:02:45Z
format Journal article
id oxford-uuid:8a45442b-cb9f-43b6-99c6-a1176c93c579
institution University of Oxford
last_indexed 2024-03-07T01:02:45Z
publishDate 2016
publisher IEEE
record_format dspace
spelling oxford-uuid:8a45442b-cb9f-43b6-99c6-a1176c93c5792022-03-26T22:30:29ZGap-corrected thin-film permittivity and permeability measurement with a broadband coaxial line techniqueJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:8a45442b-cb9f-43b6-99c6-a1176c93c579Symplectic Elements at OxfordIEEE2016Wang, YHooper, IEdwards, EGrant, PA technique for measuring the high frequency broadband complex permittivity and permeability of thin films from 50 MHz up to 18 GHz without the need for a reference sample for calibration is presented. A thin film for measurement is wound into a torus and inserted into a coaxial line. As a consequence, this method is suitable for measuring flexible selfsupported films and coatings fabricated on flexible substrates. With the torus axis of symmetry along the coaxial direction, the electromagnetic properties of the wound torus can be deduced from the perturbed reflection and transmission coefficients of an incident wave. However, when permittivity and permeability are then obtained, there is a contribution from the effect of air gaps that cannot be avoided between layers of the wound film, which results in an underestimation of the measured permittivity and permeability. An analytical air gap correction model has been developed to account for this air gap effect that is then validated by experiments and shown also to be consistent with finite element simulations. The relative effects of film thickness and air gap on a range of measured permittivity and permeability have been also elucidated.
spellingShingle Wang, Y
Hooper, I
Edwards, E
Grant, P
Gap-corrected thin-film permittivity and permeability measurement with a broadband coaxial line technique
title Gap-corrected thin-film permittivity and permeability measurement with a broadband coaxial line technique
title_full Gap-corrected thin-film permittivity and permeability measurement with a broadband coaxial line technique
title_fullStr Gap-corrected thin-film permittivity and permeability measurement with a broadband coaxial line technique
title_full_unstemmed Gap-corrected thin-film permittivity and permeability measurement with a broadband coaxial line technique
title_short Gap-corrected thin-film permittivity and permeability measurement with a broadband coaxial line technique
title_sort gap corrected thin film permittivity and permeability measurement with a broadband coaxial line technique
work_keys_str_mv AT wangy gapcorrectedthinfilmpermittivityandpermeabilitymeasurementwithabroadbandcoaxiallinetechnique
AT hooperi gapcorrectedthinfilmpermittivityandpermeabilitymeasurementwithabroadbandcoaxiallinetechnique
AT edwardse gapcorrectedthinfilmpermittivityandpermeabilitymeasurementwithabroadbandcoaxiallinetechnique
AT grantp gapcorrectedthinfilmpermittivityandpermeabilitymeasurementwithabroadbandcoaxiallinetechnique