High sensitivity measurement of 224Ra and 226Ra in water with an improved hydrous titanium oxide technique at the Sudbury Neutrino Observatory

The existing hydrous titanium oxide (HTiO) technique for the measurement of 224Ra and 226Ra in the water at the Sudbury Neutrino Observatory (SNO) has been changed to make it faster and less sensitive to trace impurities in the HTiO eluate. Using HTiO-loaded filters followed by cation exchange adsor...

全面介紹

書目詳細資料
Main Authors: Aharmim, B, Cleveland, B, Dai, X, Doucas, G, Farine, J, Fergani, H, Ford, R, Hahn, R, Hallman, E, Jelley, N, Lange, R, Majerus, S, Mifflin, C, Noble, A, O'Keeffe, H, Rodriguez-Jimenez, R, Sinclair, D, Yeh, M
格式: Journal article
語言:English
出版: 2009
_version_ 1826284292371644416
author Aharmim, B
Cleveland, B
Dai, X
Doucas, G
Farine, J
Fergani, H
Ford, R
Hahn, R
Hallman, E
Jelley, N
Lange, R
Majerus, S
Mifflin, C
Noble, A
O'Keeffe, H
Rodriguez-Jimenez, R
Sinclair, D
Yeh, M
author_facet Aharmim, B
Cleveland, B
Dai, X
Doucas, G
Farine, J
Fergani, H
Ford, R
Hahn, R
Hallman, E
Jelley, N
Lange, R
Majerus, S
Mifflin, C
Noble, A
O'Keeffe, H
Rodriguez-Jimenez, R
Sinclair, D
Yeh, M
author_sort Aharmim, B
collection OXFORD
description The existing hydrous titanium oxide (HTiO) technique for the measurement of 224Ra and 226Ra in the water at the Sudbury Neutrino Observatory (SNO) has been changed to make it faster and less sensitive to trace impurities in the HTiO eluate. Using HTiO-loaded filters followed by cation exchange adsorption and HTiO co-precipitation, Ra isotopes from 200 to 450 tonnes of heavy water can be extracted and concentrated into a single sample of a few millilitres with a total chemical efficiency of 50%. Combined with beta-alpha coincidence counting, this method is capable of measuring 1.5 × 10- 3 μ Bq / kg of 224Ra and 3.3 × 10- 3 μ Bq / kg of 226Ra from the 232Th and 238U decay chains, respectively, for a 275 tonne D2 O assay, which are equivalent to 4 × 10- 16 g Th/g and 3 × 10- 16 g U / g in heavy water. © 2009 Elsevier B.V.
first_indexed 2024-03-07T01:11:40Z
format Journal article
id oxford-uuid:8d3786c1-54f6-4e40-ad8f-f76302816bcd
institution University of Oxford
language English
last_indexed 2024-03-07T01:11:40Z
publishDate 2009
record_format dspace
spelling oxford-uuid:8d3786c1-54f6-4e40-ad8f-f76302816bcd2022-03-26T22:49:50ZHigh sensitivity measurement of 224Ra and 226Ra in water with an improved hydrous titanium oxide technique at the Sudbury Neutrino ObservatoryJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:8d3786c1-54f6-4e40-ad8f-f76302816bcdEnglishSymplectic Elements at Oxford2009Aharmim, BCleveland, BDai, XDoucas, GFarine, JFergani, HFord, RHahn, RHallman, EJelley, NLange, RMajerus, SMifflin, CNoble, AO'Keeffe, HRodriguez-Jimenez, RSinclair, DYeh, MThe existing hydrous titanium oxide (HTiO) technique for the measurement of 224Ra and 226Ra in the water at the Sudbury Neutrino Observatory (SNO) has been changed to make it faster and less sensitive to trace impurities in the HTiO eluate. Using HTiO-loaded filters followed by cation exchange adsorption and HTiO co-precipitation, Ra isotopes from 200 to 450 tonnes of heavy water can be extracted and concentrated into a single sample of a few millilitres with a total chemical efficiency of 50%. Combined with beta-alpha coincidence counting, this method is capable of measuring 1.5 × 10- 3 μ Bq / kg of 224Ra and 3.3 × 10- 3 μ Bq / kg of 226Ra from the 232Th and 238U decay chains, respectively, for a 275 tonne D2 O assay, which are equivalent to 4 × 10- 16 g Th/g and 3 × 10- 16 g U / g in heavy water. © 2009 Elsevier B.V.
spellingShingle Aharmim, B
Cleveland, B
Dai, X
Doucas, G
Farine, J
Fergani, H
Ford, R
Hahn, R
Hallman, E
Jelley, N
Lange, R
Majerus, S
Mifflin, C
Noble, A
O'Keeffe, H
Rodriguez-Jimenez, R
Sinclair, D
Yeh, M
High sensitivity measurement of 224Ra and 226Ra in water with an improved hydrous titanium oxide technique at the Sudbury Neutrino Observatory
title High sensitivity measurement of 224Ra and 226Ra in water with an improved hydrous titanium oxide technique at the Sudbury Neutrino Observatory
title_full High sensitivity measurement of 224Ra and 226Ra in water with an improved hydrous titanium oxide technique at the Sudbury Neutrino Observatory
title_fullStr High sensitivity measurement of 224Ra and 226Ra in water with an improved hydrous titanium oxide technique at the Sudbury Neutrino Observatory
title_full_unstemmed High sensitivity measurement of 224Ra and 226Ra in water with an improved hydrous titanium oxide technique at the Sudbury Neutrino Observatory
title_short High sensitivity measurement of 224Ra and 226Ra in water with an improved hydrous titanium oxide technique at the Sudbury Neutrino Observatory
title_sort high sensitivity measurement of 224ra and 226ra in water with an improved hydrous titanium oxide technique at the sudbury neutrino observatory
work_keys_str_mv AT aharmimb highsensitivitymeasurementof224raand226rainwaterwithanimprovedhydroustitaniumoxidetechniqueatthesudburyneutrinoobservatory
AT clevelandb highsensitivitymeasurementof224raand226rainwaterwithanimprovedhydroustitaniumoxidetechniqueatthesudburyneutrinoobservatory
AT daix highsensitivitymeasurementof224raand226rainwaterwithanimprovedhydroustitaniumoxidetechniqueatthesudburyneutrinoobservatory
AT doucasg highsensitivitymeasurementof224raand226rainwaterwithanimprovedhydroustitaniumoxidetechniqueatthesudburyneutrinoobservatory
AT farinej highsensitivitymeasurementof224raand226rainwaterwithanimprovedhydroustitaniumoxidetechniqueatthesudburyneutrinoobservatory
AT ferganih highsensitivitymeasurementof224raand226rainwaterwithanimprovedhydroustitaniumoxidetechniqueatthesudburyneutrinoobservatory
AT fordr highsensitivitymeasurementof224raand226rainwaterwithanimprovedhydroustitaniumoxidetechniqueatthesudburyneutrinoobservatory
AT hahnr highsensitivitymeasurementof224raand226rainwaterwithanimprovedhydroustitaniumoxidetechniqueatthesudburyneutrinoobservatory
AT hallmane highsensitivitymeasurementof224raand226rainwaterwithanimprovedhydroustitaniumoxidetechniqueatthesudburyneutrinoobservatory
AT jelleyn highsensitivitymeasurementof224raand226rainwaterwithanimprovedhydroustitaniumoxidetechniqueatthesudburyneutrinoobservatory
AT langer highsensitivitymeasurementof224raand226rainwaterwithanimprovedhydroustitaniumoxidetechniqueatthesudburyneutrinoobservatory
AT majeruss highsensitivitymeasurementof224raand226rainwaterwithanimprovedhydroustitaniumoxidetechniqueatthesudburyneutrinoobservatory
AT mifflinc highsensitivitymeasurementof224raand226rainwaterwithanimprovedhydroustitaniumoxidetechniqueatthesudburyneutrinoobservatory
AT noblea highsensitivitymeasurementof224raand226rainwaterwithanimprovedhydroustitaniumoxidetechniqueatthesudburyneutrinoobservatory
AT okeeffeh highsensitivitymeasurementof224raand226rainwaterwithanimprovedhydroustitaniumoxidetechniqueatthesudburyneutrinoobservatory
AT rodriguezjimenezr highsensitivitymeasurementof224raand226rainwaterwithanimprovedhydroustitaniumoxidetechniqueatthesudburyneutrinoobservatory
AT sinclaird highsensitivitymeasurementof224raand226rainwaterwithanimprovedhydroustitaniumoxidetechniqueatthesudburyneutrinoobservatory
AT yehm highsensitivitymeasurementof224raand226rainwaterwithanimprovedhydroustitaniumoxidetechniqueatthesudburyneutrinoobservatory