This report describes a second-generation photostimulator with four primary lights that allows independent control of the stimulation of the four receptor types in the human eye. The new design uses LEDs (with light levels controlled by eight drivers that include voltage-to-frequency converters that...

Full description

Bibliographic Details
Main Authors: Pokorny, J, Smithson, H, Quinlan, J
Format: Journal article
Language:English
Published: 2004
_version_ 1826284784974823424
author Pokorny, J
Smithson, H
Quinlan, J
author_facet Pokorny, J
Smithson, H
Quinlan, J
author_sort Pokorny, J
collection OXFORD
description This report describes a second-generation photostimulator with four primary lights that allows independent control of the stimulation of the four receptor types in the human eye. The new design uses LEDs (with light levels controlled by eight drivers that include voltage-to-frequency converters that provide 1-micros pulses at frequencies up to 250 kHz), with four center channels being combined by use of a fiber optic assembly, and likewise for four surround channels. Four fiber optic bundles are merged into a single bundle whose output is fed into a spatial homogenizer terminated by a diffuser. An interference filter is sandwiched between each LED and the fiber optic bundle. Two camera lenses collimate light from the diffusers, one for center and one for surround. The center-surround field configuration is formed by a photometric cube with a mirrored ellipse on the hypotenuse. A field lens places images of the diffusers in the plane of an artificial pupil. The fields are highly uniform. Following alignment and calibration, the center and surround fields are indistinguishable. An observer calibration procedure, designed to compensate for prereceptoral filtering, is shown by calculation to correct also for normal observer receptoral spectral sensitivity variation. With the instrument calibrated for the individual observer, a peripherally fixated 200-ms 40% contrast rod center field pulse, highly conspicuous under dark adaptation, is invisible following light adaptation.
first_indexed 2024-03-07T01:19:03Z
format Journal article
id oxford-uuid:8fb77d51-59f9-48c6-ad81-d0b4c98f9828
institution University of Oxford
language English
last_indexed 2024-03-07T01:19:03Z
publishDate 2004
record_format dspace
spelling oxford-uuid:8fb77d51-59f9-48c6-ad81-d0b4c98f98282022-03-26T23:06:20ZPhotostimulator allowing independent control of rods and the three cone types.Journal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:8fb77d51-59f9-48c6-ad81-d0b4c98f9828EnglishSymplectic Elements at Oxford2004Pokorny, JSmithson, HQuinlan, JThis report describes a second-generation photostimulator with four primary lights that allows independent control of the stimulation of the four receptor types in the human eye. The new design uses LEDs (with light levels controlled by eight drivers that include voltage-to-frequency converters that provide 1-micros pulses at frequencies up to 250 kHz), with four center channels being combined by use of a fiber optic assembly, and likewise for four surround channels. Four fiber optic bundles are merged into a single bundle whose output is fed into a spatial homogenizer terminated by a diffuser. An interference filter is sandwiched between each LED and the fiber optic bundle. Two camera lenses collimate light from the diffusers, one for center and one for surround. The center-surround field configuration is formed by a photometric cube with a mirrored ellipse on the hypotenuse. A field lens places images of the diffusers in the plane of an artificial pupil. The fields are highly uniform. Following alignment and calibration, the center and surround fields are indistinguishable. An observer calibration procedure, designed to compensate for prereceptoral filtering, is shown by calculation to correct also for normal observer receptoral spectral sensitivity variation. With the instrument calibrated for the individual observer, a peripherally fixated 200-ms 40% contrast rod center field pulse, highly conspicuous under dark adaptation, is invisible following light adaptation.
spellingShingle Pokorny, J
Smithson, H
Quinlan, J
Photostimulator allowing independent control of rods and the three cone types.
title Photostimulator allowing independent control of rods and the three cone types.
title_full Photostimulator allowing independent control of rods and the three cone types.
title_fullStr Photostimulator allowing independent control of rods and the three cone types.
title_full_unstemmed Photostimulator allowing independent control of rods and the three cone types.
title_short Photostimulator allowing independent control of rods and the three cone types.
title_sort photostimulator allowing independent control of rods and the three cone types
work_keys_str_mv AT pokornyj photostimulatorallowingindependentcontrolofrodsandthethreeconetypes
AT smithsonh photostimulatorallowingindependentcontrolofrodsandthethreeconetypes
AT quinlanj photostimulatorallowingindependentcontrolofrodsandthethreeconetypes