Preliminary studies of radiation coupling between remote soft X-ray laser amplifiers
Coupling of a soft X-ray laser beam with a relaying concave mirror in a sequentially pumped amplifier geometry using the Ne-like Ge system has been studied experimentally. Preliminary observations indicate an increase in the spatial coherence of the amplified relayed beam. In addition, near-field im...
Autors principals: | , , , , , , , , , , , , , , |
---|---|
Format: | Journal article |
Idioma: | English |
Publicat: |
Springer-Verlag
1994
|
Sumari: | Coupling of a soft X-ray laser beam with a relaying concave mirror in a sequentially pumped amplifier geometry using the Ne-like Ge system has been studied experimentally. Preliminary observations indicate an increase in the spatial coherence of the amplified relayed beam. In addition, near-field imaging of one of the amplifier plasmas shows a double-lobed intensity pattern of the emergent beam indicating refractive guiding of the amplified beam with components both normal and tangential to the target surface. © 1994 Springer-Verlag. |
---|