Magnetic resonance imaging of cortical bone with ultrashort TE pulse sequences.

PURPOSE: Normal adult cortical bone has a very short T(2) and characteristically produces no signal with pulse sequence echo times (TEs) routinely used in clinical practice. We wished to determine whether it was possible to use ultrashort TE (UTE) pulse sequences to detect signal from cortical bone...

Full description

Bibliographic Details
Main Authors: Reichert, I, Robson, M, Gatehouse, P, He, T, Chappell, K, Holmes, J, Girgis, S, Bydder, G
Format: Journal article
Language:English
Published: 2005
_version_ 1797082201050841088
author Reichert, I
Robson, M
Gatehouse, P
He, T
Chappell, K
Holmes, J
Girgis, S
Bydder, G
author_facet Reichert, I
Robson, M
Gatehouse, P
He, T
Chappell, K
Holmes, J
Girgis, S
Bydder, G
author_sort Reichert, I
collection OXFORD
description PURPOSE: Normal adult cortical bone has a very short T(2) and characteristically produces no signal with pulse sequence echo times (TEs) routinely used in clinical practice. We wished to determine whether it was possible to use ultrashort TE (UTE) pulse sequences to detect signal from cortical bone in human subjects and use this signal to characterise this tissue. SUBJECTS AND METHODS: Seven volunteers and 10 patients were examined using ultrashort TE pulse sequences (TE=0.07 or 0.08 ms). Short and long inversion as well as fat suppression pulses were used as preparation pulses. Later echo images were also obtained as well as difference images produced by subtracting a later echo image from a first echo image. Saturation pulses were used for T(1) measurement and sequences with progressively increasing TEs for T(2)* measurement. Intravenous gadodiamide was administered to four subjects. RESULTS: Signal in cortical bone was detected with UTE sequences in children, normal adults and patients. This signal was usually made more obvious by subtracting a later echo image from the first provided that the signal-to-noise ratio was sufficiently high. Normal mean adult T(1)s ranged from 140 to 260 ms, and mean T(2)*s ranged from 0.42 to 0.50 ms. T(1) increased significantly with age (P<.01). Increased signal was observed after contrast enhancement in the normal volunteer and the three patients to whom it was administered. Reduction in signal from short T(2) components was seen in acute fractures, and increase in signal in these components was seen with new bone formation after fracture malunion. In a case of osteoporosis, bone cross-sectional area and signal level appeared reduced. CONCLUSION: Signal can be detected from normal and abnormal cortical bone with UTE pulse sequences, and this can be used to measure its T(1) and T(2)* as well as observe contrast enhancement. Difference images are of value in increasing the conspicuity of cortical bone and observing abnormalities in disease.
first_indexed 2024-03-07T01:24:51Z
format Journal article
id oxford-uuid:919dfaed-1ff1-4744-a514-c12670c5ed73
institution University of Oxford
language English
last_indexed 2024-03-07T01:24:51Z
publishDate 2005
record_format dspace
spelling oxford-uuid:919dfaed-1ff1-4744-a514-c12670c5ed732022-03-26T23:19:58ZMagnetic resonance imaging of cortical bone with ultrashort TE pulse sequences.Journal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:919dfaed-1ff1-4744-a514-c12670c5ed73EnglishSymplectic Elements at Oxford2005Reichert, IRobson, MGatehouse, PHe, TChappell, KHolmes, JGirgis, SBydder, G PURPOSE: Normal adult cortical bone has a very short T(2) and characteristically produces no signal with pulse sequence echo times (TEs) routinely used in clinical practice. We wished to determine whether it was possible to use ultrashort TE (UTE) pulse sequences to detect signal from cortical bone in human subjects and use this signal to characterise this tissue. SUBJECTS AND METHODS: Seven volunteers and 10 patients were examined using ultrashort TE pulse sequences (TE=0.07 or 0.08 ms). Short and long inversion as well as fat suppression pulses were used as preparation pulses. Later echo images were also obtained as well as difference images produced by subtracting a later echo image from a first echo image. Saturation pulses were used for T(1) measurement and sequences with progressively increasing TEs for T(2)* measurement. Intravenous gadodiamide was administered to four subjects. RESULTS: Signal in cortical bone was detected with UTE sequences in children, normal adults and patients. This signal was usually made more obvious by subtracting a later echo image from the first provided that the signal-to-noise ratio was sufficiently high. Normal mean adult T(1)s ranged from 140 to 260 ms, and mean T(2)*s ranged from 0.42 to 0.50 ms. T(1) increased significantly with age (P<.01). Increased signal was observed after contrast enhancement in the normal volunteer and the three patients to whom it was administered. Reduction in signal from short T(2) components was seen in acute fractures, and increase in signal in these components was seen with new bone formation after fracture malunion. In a case of osteoporosis, bone cross-sectional area and signal level appeared reduced. CONCLUSION: Signal can be detected from normal and abnormal cortical bone with UTE pulse sequences, and this can be used to measure its T(1) and T(2)* as well as observe contrast enhancement. Difference images are of value in increasing the conspicuity of cortical bone and observing abnormalities in disease.
spellingShingle Reichert, I
Robson, M
Gatehouse, P
He, T
Chappell, K
Holmes, J
Girgis, S
Bydder, G
Magnetic resonance imaging of cortical bone with ultrashort TE pulse sequences.
title Magnetic resonance imaging of cortical bone with ultrashort TE pulse sequences.
title_full Magnetic resonance imaging of cortical bone with ultrashort TE pulse sequences.
title_fullStr Magnetic resonance imaging of cortical bone with ultrashort TE pulse sequences.
title_full_unstemmed Magnetic resonance imaging of cortical bone with ultrashort TE pulse sequences.
title_short Magnetic resonance imaging of cortical bone with ultrashort TE pulse sequences.
title_sort magnetic resonance imaging of cortical bone with ultrashort te pulse sequences
work_keys_str_mv AT reicherti magneticresonanceimagingofcorticalbonewithultrashorttepulsesequences
AT robsonm magneticresonanceimagingofcorticalbonewithultrashorttepulsesequences
AT gatehousep magneticresonanceimagingofcorticalbonewithultrashorttepulsesequences
AT het magneticresonanceimagingofcorticalbonewithultrashorttepulsesequences
AT chappellk magneticresonanceimagingofcorticalbonewithultrashorttepulsesequences
AT holmesj magneticresonanceimagingofcorticalbonewithultrashorttepulsesequences
AT girgiss magneticresonanceimagingofcorticalbonewithultrashorttepulsesequences
AT bydderg magneticresonanceimagingofcorticalbonewithultrashorttepulsesequences