First-in-human study of the safety and viability of intraocular robotic surgery

Microsurgery of the retina would be dramatically improved by instruments that offer supra-human precision. Here, we report the results of a first-in-human study of remotely controlled robot-assisted retinal surgery performed through a telemanipulation device. Specifically, 12 patients that required...

Full description

Bibliographic Details
Main Authors: Edwards, T, Xue, K, Meenink, H, Beelen, M, Naus, G, Simunovic, M, Latasiewicz, M, Farmery, A, de Smet, M, MacLaren, R
Format: Journal article
Published: Macmillan Publishers Limited 2018
_version_ 1797082919725957120
author Edwards, T
Xue, K
Meenink, H
Beelen, M
Naus, G
Simunovic, M
Latasiewicz, M
Farmery, A
de Smet, M
MacLaren, R
author_facet Edwards, T
Xue, K
Meenink, H
Beelen, M
Naus, G
Simunovic, M
Latasiewicz, M
Farmery, A
de Smet, M
MacLaren, R
author_sort Edwards, T
collection OXFORD
description Microsurgery of the retina would be dramatically improved by instruments that offer supra-human precision. Here, we report the results of a first-in-human study of remotely controlled robot-assisted retinal surgery performed through a telemanipulation device. Specifically, 12 patients that required dissection of the epiretinal or inner limiting membrane over the macula were randomly assigned to either undergo robot-assisted surgery or manual surgery, under general anaesthesia. We evaluated surgical success, the duration of surgery and the amount of retinal microtrauma as a proxy for safety. Surgical outcomes were equally successful in the robotic surgery and manual surgery groups. Differences in the amount of retinal microtrauma between the two groups were statistically insignificant, yet dissection took longer with robotic surgery (median time: 4 min 55 s) than with manual surgery (1 min 20 s). We also show the feasibility of using the robot to inject recombinant tissue plasminogen activator under the retina to displace sight-threatening haemorrhage in three patients under local anaesthesia. A safe and viable robotic system for intraocular surgery would enable precise and minimally traumatic delivery of gene therapy or cell therapy to the retina.
first_indexed 2024-03-07T01:34:44Z
format Journal article
id oxford-uuid:94c24891-1242-4bd3-ba9c-033287fa9e30
institution University of Oxford
last_indexed 2024-03-07T01:34:44Z
publishDate 2018
publisher Macmillan Publishers Limited
record_format dspace
spelling oxford-uuid:94c24891-1242-4bd3-ba9c-033287fa9e302022-03-26T23:41:40ZFirst-in-human study of the safety and viability of intraocular robotic surgeryJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:94c24891-1242-4bd3-ba9c-033287fa9e30Symplectic Elements at OxfordMacmillan Publishers Limited2018Edwards, TXue, KMeenink, HBeelen, MNaus, GSimunovic, MLatasiewicz, MFarmery, Ade Smet, MMacLaren, RMicrosurgery of the retina would be dramatically improved by instruments that offer supra-human precision. Here, we report the results of a first-in-human study of remotely controlled robot-assisted retinal surgery performed through a telemanipulation device. Specifically, 12 patients that required dissection of the epiretinal or inner limiting membrane over the macula were randomly assigned to either undergo robot-assisted surgery or manual surgery, under general anaesthesia. We evaluated surgical success, the duration of surgery and the amount of retinal microtrauma as a proxy for safety. Surgical outcomes were equally successful in the robotic surgery and manual surgery groups. Differences in the amount of retinal microtrauma between the two groups were statistically insignificant, yet dissection took longer with robotic surgery (median time: 4 min 55 s) than with manual surgery (1 min 20 s). We also show the feasibility of using the robot to inject recombinant tissue plasminogen activator under the retina to displace sight-threatening haemorrhage in three patients under local anaesthesia. A safe and viable robotic system for intraocular surgery would enable precise and minimally traumatic delivery of gene therapy or cell therapy to the retina.
spellingShingle Edwards, T
Xue, K
Meenink, H
Beelen, M
Naus, G
Simunovic, M
Latasiewicz, M
Farmery, A
de Smet, M
MacLaren, R
First-in-human study of the safety and viability of intraocular robotic surgery
title First-in-human study of the safety and viability of intraocular robotic surgery
title_full First-in-human study of the safety and viability of intraocular robotic surgery
title_fullStr First-in-human study of the safety and viability of intraocular robotic surgery
title_full_unstemmed First-in-human study of the safety and viability of intraocular robotic surgery
title_short First-in-human study of the safety and viability of intraocular robotic surgery
title_sort first in human study of the safety and viability of intraocular robotic surgery
work_keys_str_mv AT edwardst firstinhumanstudyofthesafetyandviabilityofintraocularroboticsurgery
AT xuek firstinhumanstudyofthesafetyandviabilityofintraocularroboticsurgery
AT meeninkh firstinhumanstudyofthesafetyandviabilityofintraocularroboticsurgery
AT beelenm firstinhumanstudyofthesafetyandviabilityofintraocularroboticsurgery
AT nausg firstinhumanstudyofthesafetyandviabilityofintraocularroboticsurgery
AT simunovicm firstinhumanstudyofthesafetyandviabilityofintraocularroboticsurgery
AT latasiewiczm firstinhumanstudyofthesafetyandviabilityofintraocularroboticsurgery
AT farmerya firstinhumanstudyofthesafetyandviabilityofintraocularroboticsurgery
AT desmetm firstinhumanstudyofthesafetyandviabilityofintraocularroboticsurgery
AT maclarenr firstinhumanstudyofthesafetyandviabilityofintraocularroboticsurgery