Saturation recovery allows T1 mapping in the human heart at 7T with a commercial MRI scanner

Myocardial T1 mapping at 1.5T and 3T distinguishes powerfully between normal and diseased tissue with focal and diffuse pathology. We recently reported the first human myocardial T1s at 7T using the ShMOLLI+IE inversion recovery sequence. Yet even using a unique 7T scanner with 16kW RF output, perfe...

Full description

Bibliographic Details
Main Authors: Rodgers, C, Tao, Y, Piechnik, S, Liu, A, Francis, J, Neubauer, S, Robson, M
Format: Conference item
Published: BioMed Central 2015
_version_ 1797083482072023040
author Rodgers, C
Tao, Y
Piechnik, S
Liu, A
Francis, J
Neubauer, S
Robson, M
author_facet Rodgers, C
Tao, Y
Piechnik, S
Liu, A
Francis, J
Neubauer, S
Robson, M
author_sort Rodgers, C
collection OXFORD
description Myocardial T1 mapping at 1.5T and 3T distinguishes powerfully between normal and diseased tissue with focal and diffuse pathology. We recently reported the first human myocardial T1s at 7T using the ShMOLLI+IE inversion recovery sequence. Yet even using a unique 7T scanner with 16kW RF output, perfect magnetization inversion was impossible. We now introduce a saturation recovery method to enable myocardial T1 mapping with standard commercial 7T MRI scanners.
first_indexed 2024-03-07T01:42:15Z
format Conference item
id oxford-uuid:97457f9a-cbc6-49e2-bf34-f03209012bba
institution University of Oxford
last_indexed 2024-03-07T01:42:15Z
publishDate 2015
publisher BioMed Central
record_format dspace
spelling oxford-uuid:97457f9a-cbc6-49e2-bf34-f03209012bba2022-03-26T23:58:23ZSaturation recovery allows T1 mapping in the human heart at 7T with a commercial MRI scannerConference itemhttp://purl.org/coar/resource_type/c_5794uuid:97457f9a-cbc6-49e2-bf34-f03209012bbaSymplectic Elements at OxfordBioMed Central2015Rodgers, CTao, YPiechnik, SLiu, AFrancis, JNeubauer, SRobson, MMyocardial T1 mapping at 1.5T and 3T distinguishes powerfully between normal and diseased tissue with focal and diffuse pathology. We recently reported the first human myocardial T1s at 7T using the ShMOLLI+IE inversion recovery sequence. Yet even using a unique 7T scanner with 16kW RF output, perfect magnetization inversion was impossible. We now introduce a saturation recovery method to enable myocardial T1 mapping with standard commercial 7T MRI scanners.
spellingShingle Rodgers, C
Tao, Y
Piechnik, S
Liu, A
Francis, J
Neubauer, S
Robson, M
Saturation recovery allows T1 mapping in the human heart at 7T with a commercial MRI scanner
title Saturation recovery allows T1 mapping in the human heart at 7T with a commercial MRI scanner
title_full Saturation recovery allows T1 mapping in the human heart at 7T with a commercial MRI scanner
title_fullStr Saturation recovery allows T1 mapping in the human heart at 7T with a commercial MRI scanner
title_full_unstemmed Saturation recovery allows T1 mapping in the human heart at 7T with a commercial MRI scanner
title_short Saturation recovery allows T1 mapping in the human heart at 7T with a commercial MRI scanner
title_sort saturation recovery allows t1 mapping in the human heart at 7t with a commercial mri scanner
work_keys_str_mv AT rodgersc saturationrecoveryallowst1mappinginthehumanheartat7twithacommercialmriscanner
AT taoy saturationrecoveryallowst1mappinginthehumanheartat7twithacommercialmriscanner
AT piechniks saturationrecoveryallowst1mappinginthehumanheartat7twithacommercialmriscanner
AT liua saturationrecoveryallowst1mappinginthehumanheartat7twithacommercialmriscanner
AT francisj saturationrecoveryallowst1mappinginthehumanheartat7twithacommercialmriscanner
AT neubauers saturationrecoveryallowst1mappinginthehumanheartat7twithacommercialmriscanner
AT robsonm saturationrecoveryallowst1mappinginthehumanheartat7twithacommercialmriscanner