A sensitive reagentless pH probe with a ca. 120 mV/pH unit response
The use of a basal plane pyrolitic graphite electrode immobilised with two redox active species each capable of undergoing a two-electron, two-proton redox process has allowed the development of a sensitive pH probe over a wide pH and temperature range. When the values of the peak potentials of the...
Main Authors: | , , , , , , , |
---|---|
Format: | Journal article |
Language: | English |
Published: |
2004
|
_version_ | 1797083940987600896 |
---|---|
author | Streeter, I Leventis, H Wildgoose, G Pandurangappa, M Lawrence, N Jiang, L Jones, T Compton, R |
author_facet | Streeter, I Leventis, H Wildgoose, G Pandurangappa, M Lawrence, N Jiang, L Jones, T Compton, R |
author_sort | Streeter, I |
collection | OXFORD |
description | The use of a basal plane pyrolitic graphite electrode immobilised with two redox active species each capable of undergoing a two-electron, two-proton redox process has allowed the development of a sensitive pH probe over a wide pH and temperature range. When the values of the peak potentials of the two processes are combined they shift by ca. 120 mV/pH unit at 25°C, as measured against two independent, defined reference electrodes. © Springer-Verlag 2004. |
first_indexed | 2024-03-07T01:48:39Z |
format | Journal article |
id | oxford-uuid:994d686f-f4dd-401e-93b1-e39283c58e9a |
institution | University of Oxford |
language | English |
last_indexed | 2024-03-07T01:48:39Z |
publishDate | 2004 |
record_format | dspace |
spelling | oxford-uuid:994d686f-f4dd-401e-93b1-e39283c58e9a2022-03-27T00:13:22ZA sensitive reagentless pH probe with a ca. 120 mV/pH unit responseJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:994d686f-f4dd-401e-93b1-e39283c58e9aEnglishSymplectic Elements at Oxford2004Streeter, ILeventis, HWildgoose, GPandurangappa, MLawrence, NJiang, LJones, TCompton, RThe use of a basal plane pyrolitic graphite electrode immobilised with two redox active species each capable of undergoing a two-electron, two-proton redox process has allowed the development of a sensitive pH probe over a wide pH and temperature range. When the values of the peak potentials of the two processes are combined they shift by ca. 120 mV/pH unit at 25°C, as measured against two independent, defined reference electrodes. © Springer-Verlag 2004. |
spellingShingle | Streeter, I Leventis, H Wildgoose, G Pandurangappa, M Lawrence, N Jiang, L Jones, T Compton, R A sensitive reagentless pH probe with a ca. 120 mV/pH unit response |
title | A sensitive reagentless pH probe with a ca. 120 mV/pH unit response |
title_full | A sensitive reagentless pH probe with a ca. 120 mV/pH unit response |
title_fullStr | A sensitive reagentless pH probe with a ca. 120 mV/pH unit response |
title_full_unstemmed | A sensitive reagentless pH probe with a ca. 120 mV/pH unit response |
title_short | A sensitive reagentless pH probe with a ca. 120 mV/pH unit response |
title_sort | sensitive reagentless ph probe with a ca 120 mv ph unit response |
work_keys_str_mv | AT streeteri asensitivereagentlessphprobewithaca120mvphunitresponse AT leventish asensitivereagentlessphprobewithaca120mvphunitresponse AT wildgooseg asensitivereagentlessphprobewithaca120mvphunitresponse AT pandurangappam asensitivereagentlessphprobewithaca120mvphunitresponse AT lawrencen asensitivereagentlessphprobewithaca120mvphunitresponse AT jiangl asensitivereagentlessphprobewithaca120mvphunitresponse AT jonest asensitivereagentlessphprobewithaca120mvphunitresponse AT comptonr asensitivereagentlessphprobewithaca120mvphunitresponse AT streeteri sensitivereagentlessphprobewithaca120mvphunitresponse AT leventish sensitivereagentlessphprobewithaca120mvphunitresponse AT wildgooseg sensitivereagentlessphprobewithaca120mvphunitresponse AT pandurangappam sensitivereagentlessphprobewithaca120mvphunitresponse AT lawrencen sensitivereagentlessphprobewithaca120mvphunitresponse AT jiangl sensitivereagentlessphprobewithaca120mvphunitresponse AT jonest sensitivereagentlessphprobewithaca120mvphunitresponse AT comptonr sensitivereagentlessphprobewithaca120mvphunitresponse |