Testing the properties of beam-dose monitors for VHEE-FLASH radiation therapy

Very High Energy Electrons (VHEE) of 50 - 250 MeV are an attractive choice for FLASH radiation therapy (RT). Before VHEE-FLASH RT can be considered for clinical use, a reliable dosimetric and beam monitoring system needs to be developed, able to measure the dose delivered to the patient in real-time...

Full description

Bibliographic Details
Main Authors: Bateman, JJ, Burrows, PN, Dosanjh, M, Dyks, LA, Korysko, P, Et al.
Format: Conference item
Language:English
Published: JACoW Publishing 2022
_version_ 1797107505111760896
author Bateman, JJ
Burrows, PN
Dosanjh, M
Dyks, LA
Korysko, P
Et al.
author_facet Bateman, JJ
Burrows, PN
Dosanjh, M
Dyks, LA
Korysko, P
Et al.
author_sort Bateman, JJ
collection OXFORD
description Very High Energy Electrons (VHEE) of 50 - 250 MeV are an attractive choice for FLASH radiation therapy (RT). Before VHEE-FLASH RT can be considered for clinical use, a reliable dosimetric and beam monitoring system needs to be developed, able to measure the dose delivered to the patient in real-time and cut off the beam in the event of a machine fault to prevent overdosing the patient. Ionisation chambers are the standard monitors in conventional RT; however, their response saturates at the high dose rates required for FLASH. Therefore, a new dosimetry method is needed that can provide reliable measurements of the delivered dose in these conditions. Experiments using 200 MeV electrons were done at the CLEAR facility at CERN to investigate the properties of detectors such as diamond beam loss detectors, GEM foil detectors, and Timepix3 ASIC chips. From the tests, the GEM foil proved to be the most promising.
first_indexed 2024-03-07T07:17:05Z
format Conference item
id oxford-uuid:999d0788-269e-48cb-8d3a-5555bdfffc38
institution University of Oxford
language English
last_indexed 2024-03-07T07:17:05Z
publishDate 2022
publisher JACoW Publishing
record_format dspace
spelling oxford-uuid:999d0788-269e-48cb-8d3a-5555bdfffc382022-08-18T12:11:01ZTesting the properties of beam-dose monitors for VHEE-FLASH radiation therapyConference itemhttp://purl.org/coar/resource_type/c_5794uuid:999d0788-269e-48cb-8d3a-5555bdfffc38EnglishSymplectic ElementsJACoW Publishing2022Bateman, JJBurrows, PNDosanjh, MDyks, LAKorysko, PEt al.Very High Energy Electrons (VHEE) of 50 - 250 MeV are an attractive choice for FLASH radiation therapy (RT). Before VHEE-FLASH RT can be considered for clinical use, a reliable dosimetric and beam monitoring system needs to be developed, able to measure the dose delivered to the patient in real-time and cut off the beam in the event of a machine fault to prevent overdosing the patient. Ionisation chambers are the standard monitors in conventional RT; however, their response saturates at the high dose rates required for FLASH. Therefore, a new dosimetry method is needed that can provide reliable measurements of the delivered dose in these conditions. Experiments using 200 MeV electrons were done at the CLEAR facility at CERN to investigate the properties of detectors such as diamond beam loss detectors, GEM foil detectors, and Timepix3 ASIC chips. From the tests, the GEM foil proved to be the most promising.
spellingShingle Bateman, JJ
Burrows, PN
Dosanjh, M
Dyks, LA
Korysko, P
Et al.
Testing the properties of beam-dose monitors for VHEE-FLASH radiation therapy
title Testing the properties of beam-dose monitors for VHEE-FLASH radiation therapy
title_full Testing the properties of beam-dose monitors for VHEE-FLASH radiation therapy
title_fullStr Testing the properties of beam-dose monitors for VHEE-FLASH radiation therapy
title_full_unstemmed Testing the properties of beam-dose monitors for VHEE-FLASH radiation therapy
title_short Testing the properties of beam-dose monitors for VHEE-FLASH radiation therapy
title_sort testing the properties of beam dose monitors for vhee flash radiation therapy
work_keys_str_mv AT batemanjj testingthepropertiesofbeamdosemonitorsforvheeflashradiationtherapy
AT burrowspn testingthepropertiesofbeamdosemonitorsforvheeflashradiationtherapy
AT dosanjhm testingthepropertiesofbeamdosemonitorsforvheeflashradiationtherapy
AT dyksla testingthepropertiesofbeamdosemonitorsforvheeflashradiationtherapy
AT koryskop testingthepropertiesofbeamdosemonitorsforvheeflashradiationtherapy
AT etal testingthepropertiesofbeamdosemonitorsforvheeflashradiationtherapy