Loop-mediated isothermal PCR (LAMP) for the diagnosis of falciparum malaria.

A recently described loop-mediated isothermal polymerase chain reaction (LAMP) for molecular detection of Plasmodium falciparum was compared with microscopy, PfHRP2-based rapid diagnostic test (RDT), and nested polymerase chain reaction (PCR) as the "gold standard" in 115 Bangladeshi in-pa...

Full description

Bibliographic Details
Main Authors: Paris, D, Imwong, M, Faiz, A, Hasan, M, Yunus, E, Silamut, K, Lee, S, Day, N, Dondorp, A
Format: Journal article
Language:English
Published: 2007
_version_ 1797084317178920960
author Paris, D
Imwong, M
Faiz, A
Hasan, M
Yunus, E
Silamut, K
Lee, S
Day, N
Dondorp, A
author_facet Paris, D
Imwong, M
Faiz, A
Hasan, M
Yunus, E
Silamut, K
Lee, S
Day, N
Dondorp, A
author_sort Paris, D
collection OXFORD
description A recently described loop-mediated isothermal polymerase chain reaction (LAMP) for molecular detection of Plasmodium falciparum was compared with microscopy, PfHRP2-based rapid diagnostic test (RDT), and nested polymerase chain reaction (PCR) as the "gold standard" in 115 Bangladeshi in-patients with fever. DNA extraction for LAMP was conducted by conventional methods or simple heating of the sample; test results were either assessed visually or by gel electrophoresis. Conventional DNA extraction followed by gel electrophoresis had the highest agreement with the reference method (81.7%, kappa = 0.64), with a sensitivity (95% CI) of 76.1% (68.3-83.9%), comparable to RDT and microscopy, but a specificity of 89.6% (84.0-95.2%) compared with 100% for RDT and microscopy. DNA extraction by heat treatment deteriorated specificity to unacceptable levels. LAMP enables molecular diagnosis of falciparum malaria in settings with limited technical resources but will need further optimization. The results are in contrast with a higher accuracy reported in an earlier study comparing LAMP with a non-validated PCR method.
first_indexed 2024-03-07T01:53:48Z
format Journal article
id oxford-uuid:9b098624-f47e-428c-814a-7ab50e11b7b3
institution University of Oxford
language English
last_indexed 2024-03-07T01:53:48Z
publishDate 2007
record_format dspace
spelling oxford-uuid:9b098624-f47e-428c-814a-7ab50e11b7b32022-03-27T00:25:35ZLoop-mediated isothermal PCR (LAMP) for the diagnosis of falciparum malaria.Journal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:9b098624-f47e-428c-814a-7ab50e11b7b3EnglishSymplectic Elements at Oxford2007Paris, DImwong, MFaiz, AHasan, MYunus, ESilamut, KLee, SDay, NDondorp, AA recently described loop-mediated isothermal polymerase chain reaction (LAMP) for molecular detection of Plasmodium falciparum was compared with microscopy, PfHRP2-based rapid diagnostic test (RDT), and nested polymerase chain reaction (PCR) as the "gold standard" in 115 Bangladeshi in-patients with fever. DNA extraction for LAMP was conducted by conventional methods or simple heating of the sample; test results were either assessed visually or by gel electrophoresis. Conventional DNA extraction followed by gel electrophoresis had the highest agreement with the reference method (81.7%, kappa = 0.64), with a sensitivity (95% CI) of 76.1% (68.3-83.9%), comparable to RDT and microscopy, but a specificity of 89.6% (84.0-95.2%) compared with 100% for RDT and microscopy. DNA extraction by heat treatment deteriorated specificity to unacceptable levels. LAMP enables molecular diagnosis of falciparum malaria in settings with limited technical resources but will need further optimization. The results are in contrast with a higher accuracy reported in an earlier study comparing LAMP with a non-validated PCR method.
spellingShingle Paris, D
Imwong, M
Faiz, A
Hasan, M
Yunus, E
Silamut, K
Lee, S
Day, N
Dondorp, A
Loop-mediated isothermal PCR (LAMP) for the diagnosis of falciparum malaria.
title Loop-mediated isothermal PCR (LAMP) for the diagnosis of falciparum malaria.
title_full Loop-mediated isothermal PCR (LAMP) for the diagnosis of falciparum malaria.
title_fullStr Loop-mediated isothermal PCR (LAMP) for the diagnosis of falciparum malaria.
title_full_unstemmed Loop-mediated isothermal PCR (LAMP) for the diagnosis of falciparum malaria.
title_short Loop-mediated isothermal PCR (LAMP) for the diagnosis of falciparum malaria.
title_sort loop mediated isothermal pcr lamp for the diagnosis of falciparum malaria
work_keys_str_mv AT parisd loopmediatedisothermalpcrlampforthediagnosisoffalciparummalaria
AT imwongm loopmediatedisothermalpcrlampforthediagnosisoffalciparummalaria
AT faiza loopmediatedisothermalpcrlampforthediagnosisoffalciparummalaria
AT hasanm loopmediatedisothermalpcrlampforthediagnosisoffalciparummalaria
AT yunuse loopmediatedisothermalpcrlampforthediagnosisoffalciparummalaria
AT silamutk loopmediatedisothermalpcrlampforthediagnosisoffalciparummalaria
AT lees loopmediatedisothermalpcrlampforthediagnosisoffalciparummalaria
AT dayn loopmediatedisothermalpcrlampforthediagnosisoffalciparummalaria
AT dondorpa loopmediatedisothermalpcrlampforthediagnosisoffalciparummalaria