Characterization of an external cavity diode laser based ring cavity NICE-OHMS system.
The performance of an external cavity diode laser based noise immune cavity enhanced optical heterodyne molecular spectrometer is presented. To reduce the noise on the signal a ring cavity and a circuit to remove residual amplitude modulation on the pre-cavity laser radiation was implemented. We dem...
Автори: | , , , , , |
---|---|
Формат: | Journal article |
Мова: | English |
Опубліковано: |
Optical Society of American (OSA)
2009
|
_version_ | 1826287335170375680 |
---|---|
author | Bell, C Hancock, G Peverall, R Ritchie, G van Helden, J van Leeuwen, N |
author_facet | Bell, C Hancock, G Peverall, R Ritchie, G van Helden, J van Leeuwen, N |
author_sort | Bell, C |
collection | OXFORD |
description | The performance of an external cavity diode laser based noise immune cavity enhanced optical heterodyne molecular spectrometer is presented. To reduce the noise on the signal a ring cavity and a circuit to remove residual amplitude modulation on the pre-cavity laser radiation was implemented. We demonstrate a sensitivity of 4 x 10(-11) cm(-1) Hz(-1/2) using a cavity with a finesse of 2600 on a Doppler-broadened transition of CH(4) at 6610.063 cm(-1). |
first_indexed | 2024-03-07T01:57:07Z |
format | Journal article |
id | oxford-uuid:9c1505a0-6727-41e7-9dd9-d53fba0d9bba |
institution | University of Oxford |
language | English |
last_indexed | 2024-03-07T01:57:07Z |
publishDate | 2009 |
publisher | Optical Society of American (OSA) |
record_format | dspace |
spelling | oxford-uuid:9c1505a0-6727-41e7-9dd9-d53fba0d9bba2022-03-27T00:33:39ZCharacterization of an external cavity diode laser based ring cavity NICE-OHMS system.Journal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:9c1505a0-6727-41e7-9dd9-d53fba0d9bbaEnglishSymplectic Elements at OxfordOptical Society of American (OSA)2009Bell, CHancock, GPeverall, RRitchie, Gvan Helden, Jvan Leeuwen, NThe performance of an external cavity diode laser based noise immune cavity enhanced optical heterodyne molecular spectrometer is presented. To reduce the noise on the signal a ring cavity and a circuit to remove residual amplitude modulation on the pre-cavity laser radiation was implemented. We demonstrate a sensitivity of 4 x 10(-11) cm(-1) Hz(-1/2) using a cavity with a finesse of 2600 on a Doppler-broadened transition of CH(4) at 6610.063 cm(-1). |
spellingShingle | Bell, C Hancock, G Peverall, R Ritchie, G van Helden, J van Leeuwen, N Characterization of an external cavity diode laser based ring cavity NICE-OHMS system. |
title | Characterization of an external cavity diode laser based ring cavity NICE-OHMS system. |
title_full | Characterization of an external cavity diode laser based ring cavity NICE-OHMS system. |
title_fullStr | Characterization of an external cavity diode laser based ring cavity NICE-OHMS system. |
title_full_unstemmed | Characterization of an external cavity diode laser based ring cavity NICE-OHMS system. |
title_short | Characterization of an external cavity diode laser based ring cavity NICE-OHMS system. |
title_sort | characterization of an external cavity diode laser based ring cavity nice ohms system |
work_keys_str_mv | AT bellc characterizationofanexternalcavitydiodelaserbasedringcavityniceohmssystem AT hancockg characterizationofanexternalcavitydiodelaserbasedringcavityniceohmssystem AT peverallr characterizationofanexternalcavitydiodelaserbasedringcavityniceohmssystem AT ritchieg characterizationofanexternalcavitydiodelaserbasedringcavityniceohmssystem AT vanheldenj characterizationofanexternalcavitydiodelaserbasedringcavityniceohmssystem AT vanleeuwenn characterizationofanexternalcavitydiodelaserbasedringcavityniceohmssystem |