Assistive artificial intelligence for ultrasound image interpretation in regional anaesthesia: an external validation study

<p><strong>Background:</strong>&nbsp;Ultrasonound is used to identify anatomical structures during regional anaesthesia and to guide needle insertion and injection of local anaesthetic. ScanNav Anatomy Peripheral Nerve Block (Intelligent Ultrasound, Cardiff, UK) is an artificia...

Full description

Bibliographic Details
Main Authors: Bowness, JS, Burckett-St Laurent, D, Hernandez, N, Keane, PA, Lobo, C, Margetts, S, Moka, E, Pawa, A, Rosenblatt, M, Sleep, N, Taylor, A, Woodworth, G, Vasalauskaite, A, Noble, JA, Higham, H
Format: Journal article
Language:English
Published: Elsevier 2022
_version_ 1797109058671476736
author Bowness, JS
Burckett-St Laurent, D
Hernandez, N
Keane, PA
Lobo, C
Margetts, S
Moka, E
Pawa, A
Rosenblatt, M
Sleep, N
Taylor, A
Woodworth, G
Vasalauskaite, A
Noble, JA
Higham, H
author_facet Bowness, JS
Burckett-St Laurent, D
Hernandez, N
Keane, PA
Lobo, C
Margetts, S
Moka, E
Pawa, A
Rosenblatt, M
Sleep, N
Taylor, A
Woodworth, G
Vasalauskaite, A
Noble, JA
Higham, H
author_sort Bowness, JS
collection OXFORD
description <p><strong>Background:</strong>&nbsp;Ultrasonound is used to identify anatomical structures during regional anaesthesia and to guide needle insertion and injection of local anaesthetic. ScanNav Anatomy Peripheral Nerve Block (Intelligent Ultrasound, Cardiff, UK) is an artificial intelligence-based device that produces a colour overlay on real-time B-mode ultrasound to highlight anatomical structures of interest. We evaluated the accuracy of the artificial-intelligence colour overlay and its perceived influence on risk of adverse events or block failure.</p> <p><strong>Methods:</strong>&nbsp;Ultrasound-guided regional anaesthesia experts acquired 720 videos from 40 volunteers (across nine anatomical regions) without using the device. The artificial-intelligence colour overlay was subsequently applied. Three more experts independently reviewed each video (with the original unmodified video) to assess accuracy of the colour overlay in relation to key anatomical structures (true positive/negative and false positive/negative) and the potential for highlighting to modify perceived risk of adverse events (needle trauma to nerves, arteries, pleura, and peritoneum) or block failure.</p> <p><strong>Results:</strong>&nbsp;The artificial-intelligence models identified the structure of interest in 93.5% of cases (1519/1624), with a false-negative rate of 3.0% (48/1624) and a false-positive rate of 3.5% (57/1624). Highlighting was judged to reduce the risk of unwanted needle trauma to nerves, arteries, pleura, and peritoneum in 62.9&ndash;86.4% of cases (302/480 to 345/400), and to increase the risk in 0.0&ndash;1.7% (0/160 to 8/480). Risk of block failure was reported to be reduced in 81.3% of scans (585/720) and to be increased in 1.8% (13/720).</p> <p><strong>Conclusions:</strong>&nbsp;Artificial intelligence-based devices can potentially aid image acquisition and interpretation in ultrasound-guided regional anaesthesia. Further studies are necessary to demonstrate their effectiveness in supporting training and clinical practice.</p> <p><strong>Clinical trial registration:&nbsp;</strong>NCT04906018.</p>
first_indexed 2024-03-07T07:35:12Z
format Journal article
id oxford-uuid:a01eba03-a6bf-4321-bbf9-6d31ae4f6322
institution University of Oxford
language English
last_indexed 2024-03-07T07:35:12Z
publishDate 2022
publisher Elsevier
record_format dspace
spelling oxford-uuid:a01eba03-a6bf-4321-bbf9-6d31ae4f63222023-03-07T07:55:48ZAssistive artificial intelligence for ultrasound image interpretation in regional anaesthesia: an external validation studyJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:a01eba03-a6bf-4321-bbf9-6d31ae4f6322EnglishSymplectic ElementsElsevier2022Bowness, JSBurckett-St Laurent, DHernandez, NKeane, PALobo, CMargetts, SMoka, EPawa, ARosenblatt, MSleep, NTaylor, AWoodworth, GVasalauskaite, ANoble, JAHigham, H<p><strong>Background:</strong>&nbsp;Ultrasonound is used to identify anatomical structures during regional anaesthesia and to guide needle insertion and injection of local anaesthetic. ScanNav Anatomy Peripheral Nerve Block (Intelligent Ultrasound, Cardiff, UK) is an artificial intelligence-based device that produces a colour overlay on real-time B-mode ultrasound to highlight anatomical structures of interest. We evaluated the accuracy of the artificial-intelligence colour overlay and its perceived influence on risk of adverse events or block failure.</p> <p><strong>Methods:</strong>&nbsp;Ultrasound-guided regional anaesthesia experts acquired 720 videos from 40 volunteers (across nine anatomical regions) without using the device. The artificial-intelligence colour overlay was subsequently applied. Three more experts independently reviewed each video (with the original unmodified video) to assess accuracy of the colour overlay in relation to key anatomical structures (true positive/negative and false positive/negative) and the potential for highlighting to modify perceived risk of adverse events (needle trauma to nerves, arteries, pleura, and peritoneum) or block failure.</p> <p><strong>Results:</strong>&nbsp;The artificial-intelligence models identified the structure of interest in 93.5% of cases (1519/1624), with a false-negative rate of 3.0% (48/1624) and a false-positive rate of 3.5% (57/1624). Highlighting was judged to reduce the risk of unwanted needle trauma to nerves, arteries, pleura, and peritoneum in 62.9&ndash;86.4% of cases (302/480 to 345/400), and to increase the risk in 0.0&ndash;1.7% (0/160 to 8/480). Risk of block failure was reported to be reduced in 81.3% of scans (585/720) and to be increased in 1.8% (13/720).</p> <p><strong>Conclusions:</strong>&nbsp;Artificial intelligence-based devices can potentially aid image acquisition and interpretation in ultrasound-guided regional anaesthesia. Further studies are necessary to demonstrate their effectiveness in supporting training and clinical practice.</p> <p><strong>Clinical trial registration:&nbsp;</strong>NCT04906018.</p>
spellingShingle Bowness, JS
Burckett-St Laurent, D
Hernandez, N
Keane, PA
Lobo, C
Margetts, S
Moka, E
Pawa, A
Rosenblatt, M
Sleep, N
Taylor, A
Woodworth, G
Vasalauskaite, A
Noble, JA
Higham, H
Assistive artificial intelligence for ultrasound image interpretation in regional anaesthesia: an external validation study
title Assistive artificial intelligence for ultrasound image interpretation in regional anaesthesia: an external validation study
title_full Assistive artificial intelligence for ultrasound image interpretation in regional anaesthesia: an external validation study
title_fullStr Assistive artificial intelligence for ultrasound image interpretation in regional anaesthesia: an external validation study
title_full_unstemmed Assistive artificial intelligence for ultrasound image interpretation in regional anaesthesia: an external validation study
title_short Assistive artificial intelligence for ultrasound image interpretation in regional anaesthesia: an external validation study
title_sort assistive artificial intelligence for ultrasound image interpretation in regional anaesthesia an external validation study
work_keys_str_mv AT bownessjs assistiveartificialintelligenceforultrasoundimageinterpretationinregionalanaesthesiaanexternalvalidationstudy
AT burckettstlaurentd assistiveartificialintelligenceforultrasoundimageinterpretationinregionalanaesthesiaanexternalvalidationstudy
AT hernandezn assistiveartificialintelligenceforultrasoundimageinterpretationinregionalanaesthesiaanexternalvalidationstudy
AT keanepa assistiveartificialintelligenceforultrasoundimageinterpretationinregionalanaesthesiaanexternalvalidationstudy
AT loboc assistiveartificialintelligenceforultrasoundimageinterpretationinregionalanaesthesiaanexternalvalidationstudy
AT margettss assistiveartificialintelligenceforultrasoundimageinterpretationinregionalanaesthesiaanexternalvalidationstudy
AT mokae assistiveartificialintelligenceforultrasoundimageinterpretationinregionalanaesthesiaanexternalvalidationstudy
AT pawaa assistiveartificialintelligenceforultrasoundimageinterpretationinregionalanaesthesiaanexternalvalidationstudy
AT rosenblattm assistiveartificialintelligenceforultrasoundimageinterpretationinregionalanaesthesiaanexternalvalidationstudy
AT sleepn assistiveartificialintelligenceforultrasoundimageinterpretationinregionalanaesthesiaanexternalvalidationstudy
AT taylora assistiveartificialintelligenceforultrasoundimageinterpretationinregionalanaesthesiaanexternalvalidationstudy
AT woodworthg assistiveartificialintelligenceforultrasoundimageinterpretationinregionalanaesthesiaanexternalvalidationstudy
AT vasalauskaitea assistiveartificialintelligenceforultrasoundimageinterpretationinregionalanaesthesiaanexternalvalidationstudy
AT nobleja assistiveartificialintelligenceforultrasoundimageinterpretationinregionalanaesthesiaanexternalvalidationstudy
AT highamh assistiveartificialintelligenceforultrasoundimageinterpretationinregionalanaesthesiaanexternalvalidationstudy