Quantifying the effect of finite field-of-view size on radiative transfer calculations of Titan's limb spectra measured by Cassini-CIRS

The Composite InfraRed Spectrometer (CIRS) on-board the Cassini spacecraft has currently returned around three years worth of data from Saturn's largest moon Titan. One of the unique aspects of CIRS is to take high spatial resolution spectra of the limb of Titan, with sub-scale height (20-40 km...

Full description

Bibliographic Details
Main Authors: Teanby, N, Irwin, P
Format: Journal article
Language:English
Published: 2007
_version_ 1797087863480778752
author Teanby, N
Irwin, P
author_facet Teanby, N
Irwin, P
author_sort Teanby, N
collection OXFORD
description The Composite InfraRed Spectrometer (CIRS) on-board the Cassini spacecraft has currently returned around three years worth of data from Saturn's largest moon Titan. One of the unique aspects of CIRS is to take high spatial resolution spectra of the limb of Titan, with sub-scale height (20-40 km) resolutions. This is made possible by the small field-of-view (FOV) of the mid-IR detectors. However, many limb spectra have moderate to large sized FOVs, which introduces bias into retrieved profiles of temperature and abundance unless the finite FOV size is taken into account. The bias can be reduced by calculating a FOV-averaged spectrum comprising a weighted sum of a small number of spectra with infinitesimal FOVs across the FOV. Here we introduce a scheme for incorporating FOV averaging into radiative transfer calculations of CIRS spectra and quantify the errors as a function of number of FOV averaging points, FOV size, tangent altitude, and wavenumber. The optimum number of FOV averaging points for a given observation can then be found by matching the calculated FOV averaging error with the measurement error. This allows for accurate analysis of a vast amount of Cassini-CIRS data. © 2007 Springer Science+Business Media B.V.
first_indexed 2024-03-07T02:41:41Z
format Journal article
id oxford-uuid:aaa97159-7b1b-4723-b324-5d7bdc55a68d
institution University of Oxford
language English
last_indexed 2024-03-07T02:41:41Z
publishDate 2007
record_format dspace
spelling oxford-uuid:aaa97159-7b1b-4723-b324-5d7bdc55a68d2022-03-27T03:16:42ZQuantifying the effect of finite field-of-view size on radiative transfer calculations of Titan's limb spectra measured by Cassini-CIRSJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:aaa97159-7b1b-4723-b324-5d7bdc55a68dEnglishSymplectic Elements at Oxford2007Teanby, NIrwin, PThe Composite InfraRed Spectrometer (CIRS) on-board the Cassini spacecraft has currently returned around three years worth of data from Saturn's largest moon Titan. One of the unique aspects of CIRS is to take high spatial resolution spectra of the limb of Titan, with sub-scale height (20-40 km) resolutions. This is made possible by the small field-of-view (FOV) of the mid-IR detectors. However, many limb spectra have moderate to large sized FOVs, which introduces bias into retrieved profiles of temperature and abundance unless the finite FOV size is taken into account. The bias can be reduced by calculating a FOV-averaged spectrum comprising a weighted sum of a small number of spectra with infinitesimal FOVs across the FOV. Here we introduce a scheme for incorporating FOV averaging into radiative transfer calculations of CIRS spectra and quantify the errors as a function of number of FOV averaging points, FOV size, tangent altitude, and wavenumber. The optimum number of FOV averaging points for a given observation can then be found by matching the calculated FOV averaging error with the measurement error. This allows for accurate analysis of a vast amount of Cassini-CIRS data. © 2007 Springer Science+Business Media B.V.
spellingShingle Teanby, N
Irwin, P
Quantifying the effect of finite field-of-view size on radiative transfer calculations of Titan's limb spectra measured by Cassini-CIRS
title Quantifying the effect of finite field-of-view size on radiative transfer calculations of Titan's limb spectra measured by Cassini-CIRS
title_full Quantifying the effect of finite field-of-view size on radiative transfer calculations of Titan's limb spectra measured by Cassini-CIRS
title_fullStr Quantifying the effect of finite field-of-view size on radiative transfer calculations of Titan's limb spectra measured by Cassini-CIRS
title_full_unstemmed Quantifying the effect of finite field-of-view size on radiative transfer calculations of Titan's limb spectra measured by Cassini-CIRS
title_short Quantifying the effect of finite field-of-view size on radiative transfer calculations of Titan's limb spectra measured by Cassini-CIRS
title_sort quantifying the effect of finite field of view size on radiative transfer calculations of titan s limb spectra measured by cassini cirs
work_keys_str_mv AT teanbyn quantifyingtheeffectoffinitefieldofviewsizeonradiativetransfercalculationsoftitanslimbspectrameasuredbycassinicirs
AT irwinp quantifyingtheeffectoffinitefieldofviewsizeonradiativetransfercalculationsoftitanslimbspectrameasuredbycassinicirs