OBJECTIVE: To propose a standard for the conduct of visually directed transrectal high-intensity focused ultrasound (HIFU) and to offer a formal description of the changes observed on B-mode ultrasonography (US) during this procedure. We describe our early experience of using two different treatmen...

Full description

Bibliographic Details
Main Authors: Illing, R, Leslie, T, Kennedy, J, Calleary, J, Ogden, C, Emberton, M
Format: Journal article
Language:English
Published: 2006
_version_ 1826290367487541248
author Illing, R
Leslie, T
Kennedy, J
Calleary, J
Ogden, C
Emberton, M
author_facet Illing, R
Leslie, T
Kennedy, J
Calleary, J
Ogden, C
Emberton, M
author_sort Illing, R
collection OXFORD
description OBJECTIVE: To propose a standard for the conduct of visually directed transrectal high-intensity focused ultrasound (HIFU) and to offer a formal description of the changes observed on B-mode ultrasonography (US) during this procedure. We describe our early experience of using two different treatment methods; algorithm-based HIFU and visually directed HIFU for the treatment of organ-confined prostate cancer. PATIENTS AND METHODS: Between November 2004 and October 2005, 34 men were treated using the Sonablate-500 (Focus Surgery, Indianapolis, IN, USA) as primary therapy for T1 or T2 prostate cancer. None had had previous hormone therapy and all had > or = 3-month PSA nadirs recorded at the follow-up. Nine men were treated using an algorithm-based protocol (group 1) and 25 using visually directed therapy (group 2). The conduct of visually directed treatment was described and changes seen using B-mode US were categorized using three 'Uchida' grades. RESULTS The mean PSA nadir achieved in group 2 was 0.15 ng/mL, vs 1.51 ng/mL in group 1 (P < 0.005). In group 2, 21 of 25 men achieved PSA nadirs of < or = 0.2 ng/mL 3 months after treatment. Seven men achieved undetectable PSA values. The occurrence rate of treatment-related toxicity was similar in both groups. CONCLUSION: Visually directed, transrectal HIFU enables clinically important and statistically significantly lower PSA nadirs to be achieved than algorithm-based HIFU. This is the first reported experience of visually directed HIFU for the treatment of organ-confined prostate cancer. We think that this is the first attempt to standardize the conduct of therapy; such standardization facilitates teaching it, and makes it possible to derive quality standards. The standardization of the conduct of therapy is a key step in the process of health technology assessment.
first_indexed 2024-03-07T02:43:07Z
format Journal article
id oxford-uuid:ab217a62-57e8-4b1d-a7bc-1aad9a3e6a65
institution University of Oxford
language English
last_indexed 2024-03-07T02:43:07Z
publishDate 2006
record_format dspace
spelling oxford-uuid:ab217a62-57e8-4b1d-a7bc-1aad9a3e6a652022-03-27T03:19:47ZVisually directed high-intensity focused ultrasound for organ-confined prostate cancer: A proposed standard for the conduct of therapy.Journal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:ab217a62-57e8-4b1d-a7bc-1aad9a3e6a65EnglishSymplectic Elements at Oxford2006Illing, RLeslie, TKennedy, JCalleary, JOgden, CEmberton, M OBJECTIVE: To propose a standard for the conduct of visually directed transrectal high-intensity focused ultrasound (HIFU) and to offer a formal description of the changes observed on B-mode ultrasonography (US) during this procedure. We describe our early experience of using two different treatment methods; algorithm-based HIFU and visually directed HIFU for the treatment of organ-confined prostate cancer. PATIENTS AND METHODS: Between November 2004 and October 2005, 34 men were treated using the Sonablate-500 (Focus Surgery, Indianapolis, IN, USA) as primary therapy for T1 or T2 prostate cancer. None had had previous hormone therapy and all had > or = 3-month PSA nadirs recorded at the follow-up. Nine men were treated using an algorithm-based protocol (group 1) and 25 using visually directed therapy (group 2). The conduct of visually directed treatment was described and changes seen using B-mode US were categorized using three 'Uchida' grades. RESULTS The mean PSA nadir achieved in group 2 was 0.15 ng/mL, vs 1.51 ng/mL in group 1 (P < 0.005). In group 2, 21 of 25 men achieved PSA nadirs of < or = 0.2 ng/mL 3 months after treatment. Seven men achieved undetectable PSA values. The occurrence rate of treatment-related toxicity was similar in both groups. CONCLUSION: Visually directed, transrectal HIFU enables clinically important and statistically significantly lower PSA nadirs to be achieved than algorithm-based HIFU. This is the first reported experience of visually directed HIFU for the treatment of organ-confined prostate cancer. We think that this is the first attempt to standardize the conduct of therapy; such standardization facilitates teaching it, and makes it possible to derive quality standards. The standardization of the conduct of therapy is a key step in the process of health technology assessment.
spellingShingle Illing, R
Leslie, T
Kennedy, J
Calleary, J
Ogden, C
Emberton, M
Visually directed high-intensity focused ultrasound for organ-confined prostate cancer: A proposed standard for the conduct of therapy.
title Visually directed high-intensity focused ultrasound for organ-confined prostate cancer: A proposed standard for the conduct of therapy.
title_full Visually directed high-intensity focused ultrasound for organ-confined prostate cancer: A proposed standard for the conduct of therapy.
title_fullStr Visually directed high-intensity focused ultrasound for organ-confined prostate cancer: A proposed standard for the conduct of therapy.
title_full_unstemmed Visually directed high-intensity focused ultrasound for organ-confined prostate cancer: A proposed standard for the conduct of therapy.
title_short Visually directed high-intensity focused ultrasound for organ-confined prostate cancer: A proposed standard for the conduct of therapy.
title_sort visually directed high intensity focused ultrasound for organ confined prostate cancer a proposed standard for the conduct of therapy
work_keys_str_mv AT illingr visuallydirectedhighintensityfocusedultrasoundfororganconfinedprostatecanceraproposedstandardfortheconductoftherapy
AT lesliet visuallydirectedhighintensityfocusedultrasoundfororganconfinedprostatecanceraproposedstandardfortheconductoftherapy
AT kennedyj visuallydirectedhighintensityfocusedultrasoundfororganconfinedprostatecanceraproposedstandardfortheconductoftherapy
AT callearyj visuallydirectedhighintensityfocusedultrasoundfororganconfinedprostatecanceraproposedstandardfortheconductoftherapy
AT ogdenc visuallydirectedhighintensityfocusedultrasoundfororganconfinedprostatecanceraproposedstandardfortheconductoftherapy
AT embertonm visuallydirectedhighintensityfocusedultrasoundfororganconfinedprostatecanceraproposedstandardfortheconductoftherapy