Distance-adjusted motor threshold for transcranial magnetic stimulation.

OBJECTIVE: To examine the relationship between coil-cortex distance and effective cortical stimulation using transcranial magnetic stimulation (TMS) in the left and right motor cortex. We also compare the effect of coil-cortex distance using 50 and 70 mm figure-eight stimulating coils. METHODS: Coil...

Full description

Bibliographic Details
Main Authors: Stokes, M, Chambers, C, Gould, I, English, T, McNaught, E, McDonald, O, Mattingley, J
Format: Journal article
Language:English
Published: 2007
_version_ 1826290466735259648
author Stokes, M
Chambers, C
Gould, I
English, T
McNaught, E
McDonald, O
Mattingley, J
author_facet Stokes, M
Chambers, C
Gould, I
English, T
McNaught, E
McDonald, O
Mattingley, J
author_sort Stokes, M
collection OXFORD
description OBJECTIVE: To examine the relationship between coil-cortex distance and effective cortical stimulation using transcranial magnetic stimulation (TMS) in the left and right motor cortex. We also compare the effect of coil-cortex distance using 50 and 70 mm figure-eight stimulating coils. METHODS: Coil-cortex distance was manipulated within each participant using 5 and 10 mm acrylic separators placed between the coil and scalp surface. The effect of cortical stimulation was indexed by resting motor threshold (MT). RESULTS: Increasing distance between the coil and underlying cortex was associated with a steep linear increase in MT. For each additional millimetre separating the stimulating coil from the scalp surface, an additional approximately 2.8% of absolute stimulator output (approximately 0.062 T) was required to reach MT. The gradient of the observed distance effect did not differ between hemispheres, and no differences were observed between the 50 and 70 mm TMS coils. CONCLUSIONS: Coil-cortex distance directly influences the magnitude of cortical stimulation in TMS. The relationship between TMS efficacy and coil-cortex distance is well characterised by a linear function, providing a simple and effective method for scaling stimulator output to a distance adjusted MT. SIGNIFICANCE: MT measured at the scalp-surface is dependent on the underlying scalp-cortex distance, and therefore does not provide an accurate index of cortical excitability. Distance-adjusted MT provides a more accurate index of cortical excitability, and improves the safety and efficacy of MT-calibrated TMS.
first_indexed 2024-03-07T02:44:37Z
format Journal article
id oxford-uuid:ab9e28e8-4725-44e8-b945-8826abfc8c7e
institution University of Oxford
language English
last_indexed 2024-03-07T02:44:37Z
publishDate 2007
record_format dspace
spelling oxford-uuid:ab9e28e8-4725-44e8-b945-8826abfc8c7e2022-03-27T03:23:11ZDistance-adjusted motor threshold for transcranial magnetic stimulation.Journal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:ab9e28e8-4725-44e8-b945-8826abfc8c7eEnglishSymplectic Elements at Oxford2007Stokes, MChambers, CGould, IEnglish, TMcNaught, EMcDonald, OMattingley, JOBJECTIVE: To examine the relationship between coil-cortex distance and effective cortical stimulation using transcranial magnetic stimulation (TMS) in the left and right motor cortex. We also compare the effect of coil-cortex distance using 50 and 70 mm figure-eight stimulating coils. METHODS: Coil-cortex distance was manipulated within each participant using 5 and 10 mm acrylic separators placed between the coil and scalp surface. The effect of cortical stimulation was indexed by resting motor threshold (MT). RESULTS: Increasing distance between the coil and underlying cortex was associated with a steep linear increase in MT. For each additional millimetre separating the stimulating coil from the scalp surface, an additional approximately 2.8% of absolute stimulator output (approximately 0.062 T) was required to reach MT. The gradient of the observed distance effect did not differ between hemispheres, and no differences were observed between the 50 and 70 mm TMS coils. CONCLUSIONS: Coil-cortex distance directly influences the magnitude of cortical stimulation in TMS. The relationship between TMS efficacy and coil-cortex distance is well characterised by a linear function, providing a simple and effective method for scaling stimulator output to a distance adjusted MT. SIGNIFICANCE: MT measured at the scalp-surface is dependent on the underlying scalp-cortex distance, and therefore does not provide an accurate index of cortical excitability. Distance-adjusted MT provides a more accurate index of cortical excitability, and improves the safety and efficacy of MT-calibrated TMS.
spellingShingle Stokes, M
Chambers, C
Gould, I
English, T
McNaught, E
McDonald, O
Mattingley, J
Distance-adjusted motor threshold for transcranial magnetic stimulation.
title Distance-adjusted motor threshold for transcranial magnetic stimulation.
title_full Distance-adjusted motor threshold for transcranial magnetic stimulation.
title_fullStr Distance-adjusted motor threshold for transcranial magnetic stimulation.
title_full_unstemmed Distance-adjusted motor threshold for transcranial magnetic stimulation.
title_short Distance-adjusted motor threshold for transcranial magnetic stimulation.
title_sort distance adjusted motor threshold for transcranial magnetic stimulation
work_keys_str_mv AT stokesm distanceadjustedmotorthresholdfortranscranialmagneticstimulation
AT chambersc distanceadjustedmotorthresholdfortranscranialmagneticstimulation
AT gouldi distanceadjustedmotorthresholdfortranscranialmagneticstimulation
AT englisht distanceadjustedmotorthresholdfortranscranialmagneticstimulation
AT mcnaughte distanceadjustedmotorthresholdfortranscranialmagneticstimulation
AT mcdonaldo distanceadjustedmotorthresholdfortranscranialmagneticstimulation
AT mattingleyj distanceadjustedmotorthresholdfortranscranialmagneticstimulation