A novel oxygen-sensitive potassium current in rat carotid body type I cells.
1. Hypoxic stimuli depolarize carotid body type I cells causing voltage-gated calcium influx. This study investigates the cause of this membrane depolarization. Isolated type I cells from neonatal (11-16 day) rat carotid bodies were used in the experiments. 2. Tetraethylammonium (TEA; 10 mM), 1 and...
Tác giả chính: | |
---|---|
Định dạng: | Journal article |
Ngôn ngữ: | English |
Được phát hành: |
1997
|