High-sensitivity online detection for microfluidics via cavity ringdown spectroscopy

We report the coupling of cavity ringdown spectroscopy (CRDS) with a microfluidic chip fabricated using a rapid prototyping method, in order to demonstrate high-sensitivity, non-contact online detection in microfluidics. Conventional UV-vis absorption techniques are largely ineffective for microflui...

Бүрэн тодорхойлолт

Номзүйн дэлгэрэнгүй
Үндсэн зохиолчид: James, D, Oag, B, Rushworth, C, Lee, J, Davies, J, Cabral, J, Vallance, C
Формат: Journal article
Хэл сонгох:English
Хэвлэсэн: 2012
_version_ 1826291252554891264
author James, D
Oag, B
Rushworth, C
Lee, J
Davies, J
Cabral, J
Vallance, C
author_facet James, D
Oag, B
Rushworth, C
Lee, J
Davies, J
Cabral, J
Vallance, C
author_sort James, D
collection OXFORD
description We report the coupling of cavity ringdown spectroscopy (CRDS) with a microfluidic chip fabricated using a rapid prototyping method, in order to demonstrate high-sensitivity, non-contact online detection in microfluidics. Conventional UV-vis absorption techniques are largely ineffective for microfluidic detection due to the small sample volumes and short path lengths. The multipass absorption achieved in cavity ringdown spectroscopy increases the effective absorption pathlength by several orders of magnitude, and hence enhances the detection sensitivity. A cavity ringdown spectrometer, operating at a single wavelength of 532 nm for the purposes of the proof-of-concept measurements presented here, has been developed for online detection on a polymer/glass microchip fabricated by frontal photopolymerisation. High sensitivity absorption measurements on liquid samples with volumes of tens to hundreds of nanolitres and absorption pathlengths ranging from tens to hundreds of microns are demonstrated. A series of proof-of-concept experiments show that the technique has the ability to monitor both static and time-varying analyte concentrations. Firstly, the detection limit of the system is estimated from a three-standard-deviation error analysis of absorption measurements made on dilute aqueous solutions of potassium permanganate (natural absorption coefficient (4805 ± 10) M-1 cm-1 at 532 nm). The detection limit was found to be ∼210 nM for a 466 μm pathlength, corresponding to an absorption of 1.0 × 10-3 cm-1. Online pH measurements on a 20 nL sample are performed by monitoring the absorption of phenolphthalein indicator present at millimolar concentrations. Finally, CRDS has been applied, for the first time, to monitoring chemical reaction kinetics on a microfluidic chip, tracking the oscillation period of the well-known Belousov-Zhabotinsky reaction. © 2012 The Royal Society of Chemistry.
first_indexed 2024-03-07T02:56:38Z
format Journal article
id oxford-uuid:af8409fa-4171-4bef-b3fe-b2963f89f69d
institution University of Oxford
language English
last_indexed 2024-03-07T02:56:38Z
publishDate 2012
record_format dspace
spelling oxford-uuid:af8409fa-4171-4bef-b3fe-b2963f89f69d2022-03-27T03:50:09ZHigh-sensitivity online detection for microfluidics via cavity ringdown spectroscopyJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:af8409fa-4171-4bef-b3fe-b2963f89f69dEnglishSymplectic Elements at Oxford2012James, DOag, BRushworth, CLee, JDavies, JCabral, JVallance, CWe report the coupling of cavity ringdown spectroscopy (CRDS) with a microfluidic chip fabricated using a rapid prototyping method, in order to demonstrate high-sensitivity, non-contact online detection in microfluidics. Conventional UV-vis absorption techniques are largely ineffective for microfluidic detection due to the small sample volumes and short path lengths. The multipass absorption achieved in cavity ringdown spectroscopy increases the effective absorption pathlength by several orders of magnitude, and hence enhances the detection sensitivity. A cavity ringdown spectrometer, operating at a single wavelength of 532 nm for the purposes of the proof-of-concept measurements presented here, has been developed for online detection on a polymer/glass microchip fabricated by frontal photopolymerisation. High sensitivity absorption measurements on liquid samples with volumes of tens to hundreds of nanolitres and absorption pathlengths ranging from tens to hundreds of microns are demonstrated. A series of proof-of-concept experiments show that the technique has the ability to monitor both static and time-varying analyte concentrations. Firstly, the detection limit of the system is estimated from a three-standard-deviation error analysis of absorption measurements made on dilute aqueous solutions of potassium permanganate (natural absorption coefficient (4805 ± 10) M-1 cm-1 at 532 nm). The detection limit was found to be ∼210 nM for a 466 μm pathlength, corresponding to an absorption of 1.0 × 10-3 cm-1. Online pH measurements on a 20 nL sample are performed by monitoring the absorption of phenolphthalein indicator present at millimolar concentrations. Finally, CRDS has been applied, for the first time, to monitoring chemical reaction kinetics on a microfluidic chip, tracking the oscillation period of the well-known Belousov-Zhabotinsky reaction. © 2012 The Royal Society of Chemistry.
spellingShingle James, D
Oag, B
Rushworth, C
Lee, J
Davies, J
Cabral, J
Vallance, C
High-sensitivity online detection for microfluidics via cavity ringdown spectroscopy
title High-sensitivity online detection for microfluidics via cavity ringdown spectroscopy
title_full High-sensitivity online detection for microfluidics via cavity ringdown spectroscopy
title_fullStr High-sensitivity online detection for microfluidics via cavity ringdown spectroscopy
title_full_unstemmed High-sensitivity online detection for microfluidics via cavity ringdown spectroscopy
title_short High-sensitivity online detection for microfluidics via cavity ringdown spectroscopy
title_sort high sensitivity online detection for microfluidics via cavity ringdown spectroscopy
work_keys_str_mv AT jamesd highsensitivityonlinedetectionformicrofluidicsviacavityringdownspectroscopy
AT oagb highsensitivityonlinedetectionformicrofluidicsviacavityringdownspectroscopy
AT rushworthc highsensitivityonlinedetectionformicrofluidicsviacavityringdownspectroscopy
AT leej highsensitivityonlinedetectionformicrofluidicsviacavityringdownspectroscopy
AT daviesj highsensitivityonlinedetectionformicrofluidicsviacavityringdownspectroscopy
AT cabralj highsensitivityonlinedetectionformicrofluidicsviacavityringdownspectroscopy
AT vallancec highsensitivityonlinedetectionformicrofluidicsviacavityringdownspectroscopy