Reproducibility of the cervical range of motion (CROM) device for individuals with sub-acute whiplash associated disorders.

PURPOSE: The objective of this study was to evaluate the reproducibility of the cervical range of motion device when measuring both active and passive range of motion in a group of individuals with sub-acute Whiplash Associated Disorders (WAD). METHODS: Participants were recruited as part of a larg...

Full description

Bibliographic Details
Main Authors: Williams, M, Williamson, E, Gates, S, Cooke, M
Format: Journal article
Language:English
Published: 2012
_version_ 1797088934404030464
author Williams, M
Williamson, E
Gates, S
Cooke, M
author_facet Williams, M
Williamson, E
Gates, S
Cooke, M
author_sort Williams, M
collection OXFORD
description PURPOSE: The objective of this study was to evaluate the reproducibility of the cervical range of motion device when measuring both active and passive range of motion in a group of individuals with sub-acute Whiplash Associated Disorders (WAD). METHODS: Participants were recruited as part of a large multi-centre Randomised Controlled Trial from UK emergency departments. Experienced research physiotherapists measured active and passive cervical spine movements in all directions. Both intra- and inter-observer reliability and agreement were assessed using the intra-class correlation coefficient, standard error of measurement and limits of agreement methods. RESULTS: Different groups of 39 and 19 subjects were included in the intra and inter-observer studies, respectively. The CROM device demonstrated substantial intra- and inter-observer reliability and agreement for all the active and passive half-cycle movements (ICC range 0.82-0.99) with the exception of one (passive right lateral flexion for inter-observer; ICC 0.77). CONCLUSIONS: The CROM device has proven to be a reproducible measurement method for a symptomatic WAD population using the measurement protocol described and can be used with confidence to differentiate individuals according to a single measurement.
first_indexed 2024-03-07T02:57:13Z
format Journal article
id oxford-uuid:afba93f0-291b-4b01-9a58-8407e2347dc1
institution University of Oxford
language English
last_indexed 2024-03-07T02:57:13Z
publishDate 2012
record_format dspace
spelling oxford-uuid:afba93f0-291b-4b01-9a58-8407e2347dc12022-03-27T03:51:25ZReproducibility of the cervical range of motion (CROM) device for individuals with sub-acute whiplash associated disorders.Journal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:afba93f0-291b-4b01-9a58-8407e2347dc1EnglishSymplectic Elements at Oxford2012Williams, MWilliamson, EGates, SCooke, M PURPOSE: The objective of this study was to evaluate the reproducibility of the cervical range of motion device when measuring both active and passive range of motion in a group of individuals with sub-acute Whiplash Associated Disorders (WAD). METHODS: Participants were recruited as part of a large multi-centre Randomised Controlled Trial from UK emergency departments. Experienced research physiotherapists measured active and passive cervical spine movements in all directions. Both intra- and inter-observer reliability and agreement were assessed using the intra-class correlation coefficient, standard error of measurement and limits of agreement methods. RESULTS: Different groups of 39 and 19 subjects were included in the intra and inter-observer studies, respectively. The CROM device demonstrated substantial intra- and inter-observer reliability and agreement for all the active and passive half-cycle movements (ICC range 0.82-0.99) with the exception of one (passive right lateral flexion for inter-observer; ICC 0.77). CONCLUSIONS: The CROM device has proven to be a reproducible measurement method for a symptomatic WAD population using the measurement protocol described and can be used with confidence to differentiate individuals according to a single measurement.
spellingShingle Williams, M
Williamson, E
Gates, S
Cooke, M
Reproducibility of the cervical range of motion (CROM) device for individuals with sub-acute whiplash associated disorders.
title Reproducibility of the cervical range of motion (CROM) device for individuals with sub-acute whiplash associated disorders.
title_full Reproducibility of the cervical range of motion (CROM) device for individuals with sub-acute whiplash associated disorders.
title_fullStr Reproducibility of the cervical range of motion (CROM) device for individuals with sub-acute whiplash associated disorders.
title_full_unstemmed Reproducibility of the cervical range of motion (CROM) device for individuals with sub-acute whiplash associated disorders.
title_short Reproducibility of the cervical range of motion (CROM) device for individuals with sub-acute whiplash associated disorders.
title_sort reproducibility of the cervical range of motion crom device for individuals with sub acute whiplash associated disorders
work_keys_str_mv AT williamsm reproducibilityofthecervicalrangeofmotioncromdeviceforindividualswithsubacutewhiplashassociateddisorders
AT williamsone reproducibilityofthecervicalrangeofmotioncromdeviceforindividualswithsubacutewhiplashassociateddisorders
AT gatess reproducibilityofthecervicalrangeofmotioncromdeviceforindividualswithsubacutewhiplashassociateddisorders
AT cookem reproducibilityofthecervicalrangeofmotioncromdeviceforindividualswithsubacutewhiplashassociateddisorders