A review of calibrated blood oxygenation level-dependent (BOLD) methods for the measurement of task-induced changes in brain oxygen metabolism.

The dynamics of the blood oxygenation level-dependent (BOLD) response are dependent on changes in cerebral blood flow, cerebral blood volume and the cerebral metabolic rate of oxygen consumption. Furthermore, the amplitude of the response is dependent on the baseline physiological state, defined by...

詳細記述

書誌詳細
主要な著者: Blockley, N, Griffeth, V, Simon, AB, Buxton, R
フォーマット: Journal article
言語:English
出版事項: 2013
_version_ 1826291934701813760
author Blockley, N
Griffeth, V
Simon, AB
Buxton, R
author_facet Blockley, N
Griffeth, V
Simon, AB
Buxton, R
author_sort Blockley, N
collection OXFORD
description The dynamics of the blood oxygenation level-dependent (BOLD) response are dependent on changes in cerebral blood flow, cerebral blood volume and the cerebral metabolic rate of oxygen consumption. Furthermore, the amplitude of the response is dependent on the baseline physiological state, defined by the haematocrit, oxygen extraction fraction and cerebral blood volume. As a result of this complex dependence, the accurate interpretation of BOLD data and robust intersubject comparisons when the baseline physiology is varied are difficult. The calibrated BOLD technique was developed to address these issues. However, the methodology is complex and its full promise has not yet been realised. In this review, the theoretical underpinnings of calibrated BOLD, and issues regarding this theory that are still to be resolved, are discussed. Important aspects of practical implementation are reviewed and reported applications of this methodology are presented.
first_indexed 2024-03-07T03:06:58Z
format Journal article
id oxford-uuid:b2df7c2c-2ae3-488f-9c0d-2b29749ecc4a
institution University of Oxford
language English
last_indexed 2024-03-07T03:06:58Z
publishDate 2013
record_format dspace
spelling oxford-uuid:b2df7c2c-2ae3-488f-9c0d-2b29749ecc4a2022-03-27T04:14:48ZA review of calibrated blood oxygenation level-dependent (BOLD) methods for the measurement of task-induced changes in brain oxygen metabolism.Journal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:b2df7c2c-2ae3-488f-9c0d-2b29749ecc4aEnglishSymplectic Elements at Oxford2013Blockley, NGriffeth, VSimon, ABBuxton, RThe dynamics of the blood oxygenation level-dependent (BOLD) response are dependent on changes in cerebral blood flow, cerebral blood volume and the cerebral metabolic rate of oxygen consumption. Furthermore, the amplitude of the response is dependent on the baseline physiological state, defined by the haematocrit, oxygen extraction fraction and cerebral blood volume. As a result of this complex dependence, the accurate interpretation of BOLD data and robust intersubject comparisons when the baseline physiology is varied are difficult. The calibrated BOLD technique was developed to address these issues. However, the methodology is complex and its full promise has not yet been realised. In this review, the theoretical underpinnings of calibrated BOLD, and issues regarding this theory that are still to be resolved, are discussed. Important aspects of practical implementation are reviewed and reported applications of this methodology are presented.
spellingShingle Blockley, N
Griffeth, V
Simon, AB
Buxton, R
A review of calibrated blood oxygenation level-dependent (BOLD) methods for the measurement of task-induced changes in brain oxygen metabolism.
title A review of calibrated blood oxygenation level-dependent (BOLD) methods for the measurement of task-induced changes in brain oxygen metabolism.
title_full A review of calibrated blood oxygenation level-dependent (BOLD) methods for the measurement of task-induced changes in brain oxygen metabolism.
title_fullStr A review of calibrated blood oxygenation level-dependent (BOLD) methods for the measurement of task-induced changes in brain oxygen metabolism.
title_full_unstemmed A review of calibrated blood oxygenation level-dependent (BOLD) methods for the measurement of task-induced changes in brain oxygen metabolism.
title_short A review of calibrated blood oxygenation level-dependent (BOLD) methods for the measurement of task-induced changes in brain oxygen metabolism.
title_sort review of calibrated blood oxygenation level dependent bold methods for the measurement of task induced changes in brain oxygen metabolism
work_keys_str_mv AT blockleyn areviewofcalibratedbloodoxygenationleveldependentboldmethodsforthemeasurementoftaskinducedchangesinbrainoxygenmetabolism
AT griffethv areviewofcalibratedbloodoxygenationleveldependentboldmethodsforthemeasurementoftaskinducedchangesinbrainoxygenmetabolism
AT simonab areviewofcalibratedbloodoxygenationleveldependentboldmethodsforthemeasurementoftaskinducedchangesinbrainoxygenmetabolism
AT buxtonr areviewofcalibratedbloodoxygenationleveldependentboldmethodsforthemeasurementoftaskinducedchangesinbrainoxygenmetabolism
AT blockleyn reviewofcalibratedbloodoxygenationleveldependentboldmethodsforthemeasurementoftaskinducedchangesinbrainoxygenmetabolism
AT griffethv reviewofcalibratedbloodoxygenationleveldependentboldmethodsforthemeasurementoftaskinducedchangesinbrainoxygenmetabolism
AT simonab reviewofcalibratedbloodoxygenationleveldependentboldmethodsforthemeasurementoftaskinducedchangesinbrainoxygenmetabolism
AT buxtonr reviewofcalibratedbloodoxygenationleveldependentboldmethodsforthemeasurementoftaskinducedchangesinbrainoxygenmetabolism