A review of calibrated blood oxygenation level-dependent (BOLD) methods for the measurement of task-induced changes in brain oxygen metabolism.
The dynamics of the blood oxygenation level-dependent (BOLD) response are dependent on changes in cerebral blood flow, cerebral blood volume and the cerebral metabolic rate of oxygen consumption. Furthermore, the amplitude of the response is dependent on the baseline physiological state, defined by...
Үндсэн зохиолчид: | , , , |
---|---|
Формат: | Journal article |
Хэл сонгох: | English |
Хэвлэсэн: |
2013
|
_version_ | 1826291934701813760 |
---|---|
author | Blockley, N Griffeth, V Simon, AB Buxton, R |
author_facet | Blockley, N Griffeth, V Simon, AB Buxton, R |
author_sort | Blockley, N |
collection | OXFORD |
description | The dynamics of the blood oxygenation level-dependent (BOLD) response are dependent on changes in cerebral blood flow, cerebral blood volume and the cerebral metabolic rate of oxygen consumption. Furthermore, the amplitude of the response is dependent on the baseline physiological state, defined by the haematocrit, oxygen extraction fraction and cerebral blood volume. As a result of this complex dependence, the accurate interpretation of BOLD data and robust intersubject comparisons when the baseline physiology is varied are difficult. The calibrated BOLD technique was developed to address these issues. However, the methodology is complex and its full promise has not yet been realised. In this review, the theoretical underpinnings of calibrated BOLD, and issues regarding this theory that are still to be resolved, are discussed. Important aspects of practical implementation are reviewed and reported applications of this methodology are presented. |
first_indexed | 2024-03-07T03:06:58Z |
format | Journal article |
id | oxford-uuid:b2df7c2c-2ae3-488f-9c0d-2b29749ecc4a |
institution | University of Oxford |
language | English |
last_indexed | 2024-03-07T03:06:58Z |
publishDate | 2013 |
record_format | dspace |
spelling | oxford-uuid:b2df7c2c-2ae3-488f-9c0d-2b29749ecc4a2022-03-27T04:14:48ZA review of calibrated blood oxygenation level-dependent (BOLD) methods for the measurement of task-induced changes in brain oxygen metabolism.Journal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:b2df7c2c-2ae3-488f-9c0d-2b29749ecc4aEnglishSymplectic Elements at Oxford2013Blockley, NGriffeth, VSimon, ABBuxton, RThe dynamics of the blood oxygenation level-dependent (BOLD) response are dependent on changes in cerebral blood flow, cerebral blood volume and the cerebral metabolic rate of oxygen consumption. Furthermore, the amplitude of the response is dependent on the baseline physiological state, defined by the haematocrit, oxygen extraction fraction and cerebral blood volume. As a result of this complex dependence, the accurate interpretation of BOLD data and robust intersubject comparisons when the baseline physiology is varied are difficult. The calibrated BOLD technique was developed to address these issues. However, the methodology is complex and its full promise has not yet been realised. In this review, the theoretical underpinnings of calibrated BOLD, and issues regarding this theory that are still to be resolved, are discussed. Important aspects of practical implementation are reviewed and reported applications of this methodology are presented. |
spellingShingle | Blockley, N Griffeth, V Simon, AB Buxton, R A review of calibrated blood oxygenation level-dependent (BOLD) methods for the measurement of task-induced changes in brain oxygen metabolism. |
title | A review of calibrated blood oxygenation level-dependent (BOLD) methods for the measurement of task-induced changes in brain oxygen metabolism. |
title_full | A review of calibrated blood oxygenation level-dependent (BOLD) methods for the measurement of task-induced changes in brain oxygen metabolism. |
title_fullStr | A review of calibrated blood oxygenation level-dependent (BOLD) methods for the measurement of task-induced changes in brain oxygen metabolism. |
title_full_unstemmed | A review of calibrated blood oxygenation level-dependent (BOLD) methods for the measurement of task-induced changes in brain oxygen metabolism. |
title_short | A review of calibrated blood oxygenation level-dependent (BOLD) methods for the measurement of task-induced changes in brain oxygen metabolism. |
title_sort | review of calibrated blood oxygenation level dependent bold methods for the measurement of task induced changes in brain oxygen metabolism |
work_keys_str_mv | AT blockleyn areviewofcalibratedbloodoxygenationleveldependentboldmethodsforthemeasurementoftaskinducedchangesinbrainoxygenmetabolism AT griffethv areviewofcalibratedbloodoxygenationleveldependentboldmethodsforthemeasurementoftaskinducedchangesinbrainoxygenmetabolism AT simonab areviewofcalibratedbloodoxygenationleveldependentboldmethodsforthemeasurementoftaskinducedchangesinbrainoxygenmetabolism AT buxtonr areviewofcalibratedbloodoxygenationleveldependentboldmethodsforthemeasurementoftaskinducedchangesinbrainoxygenmetabolism AT blockleyn reviewofcalibratedbloodoxygenationleveldependentboldmethodsforthemeasurementoftaskinducedchangesinbrainoxygenmetabolism AT griffethv reviewofcalibratedbloodoxygenationleveldependentboldmethodsforthemeasurementoftaskinducedchangesinbrainoxygenmetabolism AT simonab reviewofcalibratedbloodoxygenationleveldependentboldmethodsforthemeasurementoftaskinducedchangesinbrainoxygenmetabolism AT buxtonr reviewofcalibratedbloodoxygenationleveldependentboldmethodsforthemeasurementoftaskinducedchangesinbrainoxygenmetabolism |