3D reconstruction of coronary arteries from 2D angiographic projections using non-uniform rational basis splines (NURBS) for accurate modelling of coronary stenoses

<p><strong>Objective</strong><br/>Assessment of coronary stenosis severity is crucial in clinical practice. This study proposes a novel method to generate 3D models of stenotic coronary arteries, directly from 2D coronary images, and suitable for immediate assessment of the s...

Full description

Bibliographic Details
Main Authors: Galassi, F, Alkhalil, M, Lee, R, Martindale, P, Kharbanda, R, Channon, K, Grau, V, Choudhury, R
Format: Journal article
Language:English
Published: Public Library of Science 2018
_version_ 1826292365945470976
author Galassi, F
Alkhalil, M
Lee, R
Martindale, P
Kharbanda, R
Channon, K
Grau, V
Choudhury, R
author_facet Galassi, F
Alkhalil, M
Lee, R
Martindale, P
Kharbanda, R
Channon, K
Grau, V
Choudhury, R
author_sort Galassi, F
collection OXFORD
description <p><strong>Objective</strong><br/>Assessment of coronary stenosis severity is crucial in clinical practice. This study proposes a novel method to generate 3D models of stenotic coronary arteries, directly from 2D coronary images, and suitable for immediate assessment of the stenosis severity.</p> <p><strong>Methods</strong><br/>From multiple 2D X-ray coronary arteriogram projections, 2D vessels were extracted. A 3D centreline was reconstructed as intersection of surfaces from corresponding branches. Next, 3D luminal contours were generated in a two-step process: first, a Non-Uniform Rational B-Spline (NURBS) circular contour was designed and, second, its control points were adjusted to interpolate computed 3D boundary points. Finally, a 3D surface was generated as an interpolation across the control points of the contours and used in the analysis of the severity of a lesion. To evaluate the method, we compared 3D reconstructed lesions with Optical Coherence Tomography (OCT), an invasive imaging modality that enables high-resolution endoluminal visualization of lesion anatomy.</p> <p><strong>Results</strong><br/>Validation was performed on routine clinical data. Analysis of paired cross-sectional area discrepancies indicated that the proposed method more closely represented OCT contours than conventional approaches in luminal surface reconstruction, with overall root-mean-square errors ranging from 0.213mm2 to 1.013mm2, and maximum error of 1.837mm2. Comparison of volume reduction due to a lesion with corresponding FFR measurement suggests that the method may help in estimating the physiological significance of a lesion.</p> <p><strong>Conclusion</strong><br/>The algorithm accurately reconstructed 3D models of lesioned arteries and enabled quantitative assessment of stenoses. The proposed method has the potential to allow immediate analysis of the stenoses in clinical practice, thereby providing incremental diagnostic and prognostic information to guide treatments in real time and without the need for invasive techniques.</p>
first_indexed 2024-03-07T03:13:34Z
format Journal article
id oxford-uuid:b50a92fd-69f5-4835-81b7-f422aecb60e3
institution University of Oxford
language English
last_indexed 2024-03-07T03:13:34Z
publishDate 2018
publisher Public Library of Science
record_format dspace
spelling oxford-uuid:b50a92fd-69f5-4835-81b7-f422aecb60e32022-03-27T04:30:25Z3D reconstruction of coronary arteries from 2D angiographic projections using non-uniform rational basis splines (NURBS) for accurate modelling of coronary stenosesJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:b50a92fd-69f5-4835-81b7-f422aecb60e3EnglishSymplectic Elements at OxfordPublic Library of Science2018Galassi, FAlkhalil, MLee, RMartindale, PKharbanda, RChannon, KGrau, VChoudhury, R<p><strong>Objective</strong><br/>Assessment of coronary stenosis severity is crucial in clinical practice. This study proposes a novel method to generate 3D models of stenotic coronary arteries, directly from 2D coronary images, and suitable for immediate assessment of the stenosis severity.</p> <p><strong>Methods</strong><br/>From multiple 2D X-ray coronary arteriogram projections, 2D vessels were extracted. A 3D centreline was reconstructed as intersection of surfaces from corresponding branches. Next, 3D luminal contours were generated in a two-step process: first, a Non-Uniform Rational B-Spline (NURBS) circular contour was designed and, second, its control points were adjusted to interpolate computed 3D boundary points. Finally, a 3D surface was generated as an interpolation across the control points of the contours and used in the analysis of the severity of a lesion. To evaluate the method, we compared 3D reconstructed lesions with Optical Coherence Tomography (OCT), an invasive imaging modality that enables high-resolution endoluminal visualization of lesion anatomy.</p> <p><strong>Results</strong><br/>Validation was performed on routine clinical data. Analysis of paired cross-sectional area discrepancies indicated that the proposed method more closely represented OCT contours than conventional approaches in luminal surface reconstruction, with overall root-mean-square errors ranging from 0.213mm2 to 1.013mm2, and maximum error of 1.837mm2. Comparison of volume reduction due to a lesion with corresponding FFR measurement suggests that the method may help in estimating the physiological significance of a lesion.</p> <p><strong>Conclusion</strong><br/>The algorithm accurately reconstructed 3D models of lesioned arteries and enabled quantitative assessment of stenoses. The proposed method has the potential to allow immediate analysis of the stenoses in clinical practice, thereby providing incremental diagnostic and prognostic information to guide treatments in real time and without the need for invasive techniques.</p>
spellingShingle Galassi, F
Alkhalil, M
Lee, R
Martindale, P
Kharbanda, R
Channon, K
Grau, V
Choudhury, R
3D reconstruction of coronary arteries from 2D angiographic projections using non-uniform rational basis splines (NURBS) for accurate modelling of coronary stenoses
title 3D reconstruction of coronary arteries from 2D angiographic projections using non-uniform rational basis splines (NURBS) for accurate modelling of coronary stenoses
title_full 3D reconstruction of coronary arteries from 2D angiographic projections using non-uniform rational basis splines (NURBS) for accurate modelling of coronary stenoses
title_fullStr 3D reconstruction of coronary arteries from 2D angiographic projections using non-uniform rational basis splines (NURBS) for accurate modelling of coronary stenoses
title_full_unstemmed 3D reconstruction of coronary arteries from 2D angiographic projections using non-uniform rational basis splines (NURBS) for accurate modelling of coronary stenoses
title_short 3D reconstruction of coronary arteries from 2D angiographic projections using non-uniform rational basis splines (NURBS) for accurate modelling of coronary stenoses
title_sort 3d reconstruction of coronary arteries from 2d angiographic projections using non uniform rational basis splines nurbs for accurate modelling of coronary stenoses
work_keys_str_mv AT galassif 3dreconstructionofcoronaryarteriesfrom2dangiographicprojectionsusingnonuniformrationalbasissplinesnurbsforaccuratemodellingofcoronarystenoses
AT alkhalilm 3dreconstructionofcoronaryarteriesfrom2dangiographicprojectionsusingnonuniformrationalbasissplinesnurbsforaccuratemodellingofcoronarystenoses
AT leer 3dreconstructionofcoronaryarteriesfrom2dangiographicprojectionsusingnonuniformrationalbasissplinesnurbsforaccuratemodellingofcoronarystenoses
AT martindalep 3dreconstructionofcoronaryarteriesfrom2dangiographicprojectionsusingnonuniformrationalbasissplinesnurbsforaccuratemodellingofcoronarystenoses
AT kharbandar 3dreconstructionofcoronaryarteriesfrom2dangiographicprojectionsusingnonuniformrationalbasissplinesnurbsforaccuratemodellingofcoronarystenoses
AT channonk 3dreconstructionofcoronaryarteriesfrom2dangiographicprojectionsusingnonuniformrationalbasissplinesnurbsforaccuratemodellingofcoronarystenoses
AT grauv 3dreconstructionofcoronaryarteriesfrom2dangiographicprojectionsusingnonuniformrationalbasissplinesnurbsforaccuratemodellingofcoronarystenoses
AT choudhuryr 3dreconstructionofcoronaryarteriesfrom2dangiographicprojectionsusingnonuniformrationalbasissplinesnurbsforaccuratemodellingofcoronarystenoses