Pressure‑sensitive paint diagnostic to measure species concentration on transpiration‑cooled walls - Dataset

This paper presents the performance of pressure-sensitive paint (PSP) for the direct measurement of species concentration on a porous surface with mass injection. It is used to measure the ability of an injected gas to reduce the mass transfer of freestream species to the surface. A porous alumina s...

Full description

Bibliographic Details
Main Authors: Ewenz Rocher, M, Hermann, T, McGilvray, M, Ifti, H S, Vieira, J, Hambidge, C, Quinn, M K, Grossman, M, Vandeperre, L
Format: Dataset
Language:English
Published: University of Oxford 2022
Description
Summary:This paper presents the performance of pressure-sensitive paint (PSP) for the direct measurement of species concentration on a porous surface with mass injection. It is used to measure the ability of an injected gas to reduce the mass transfer of freestream species to the surface. A porous alumina sample was sprayed with a PSP luminophore solution. The sample was installed into a flat plate model and exposed to hypersonic cross-flows in the Oxford High-Density Tunnel. Tests were conducted with no coolant injection, air injection, and nitrogen injection at increasing blowing ratios. Oxygen partial pressure maps on the transpiration-cooled surface were obtained for several conditions at unit Reynolds numbers between 2.58−5.0 × 107∕m and blowing ratios between 0.016−0.078% . The oxygen pressure decreases as the unit Reynolds number decreases and the blowing ratio increases.