Simultaneous determination of 8-oxo-2'-deoxyguanosine and 8-oxo-2'-deoxyadenosine in DNA using online column-switching liquid chromatography/tandem mass spectrometry.

Sensitive and reliable methods are required for the assessment of oxidative DNA damage, which can result from reactive oxygen species that are generated endogenously from cellular metabolism and inflammatory responses, or by exposure to exogenous agents. The development of a liquid chromatography/ta...

Disgrifiad llawn

Manylion Llyfryddiaeth
Prif Awduron: Singh, R, Teichert, F, Verschoyle, R, Kaur, B, Vives, M, Sharma, R, Steward, W, Gescher, A, Farmer, P
Fformat: Journal article
Iaith:English
Cyhoeddwyd: 2009
_version_ 1826293150603280384
author Singh, R
Teichert, F
Verschoyle, R
Kaur, B
Vives, M
Sharma, R
Steward, W
Gescher, A
Farmer, P
author_facet Singh, R
Teichert, F
Verschoyle, R
Kaur, B
Vives, M
Sharma, R
Steward, W
Gescher, A
Farmer, P
author_sort Singh, R
collection OXFORD
description Sensitive and reliable methods are required for the assessment of oxidative DNA damage, which can result from reactive oxygen species that are generated endogenously from cellular metabolism and inflammatory responses, or by exposure to exogenous agents. The development of a liquid chromatography/tandem mass spectrometry (LC/MS/MS) selected reaction monitoring (SRM) method is described, that utilises online column-switching valve technology for the simultaneous determination of two DNA adduct biomarkers of oxidative stress, 8-oxo-7,8-dihydro-2'-deoxyguanosine (8-oxodG) and 8-oxo-7,8-dihydro-2'-deoxyadenosine (8-oxodA). To allow for the accurate quantitation of both adducts the corresponding [(15)N(5)]-labelled stable isotope internal standards were synthesised and added prior to enzymatic hydrolysis of the DNA samples to 2'-deoxynucleosides. The method required between 10 and 40 microg of hydrolysed DNA on-column for the analysis and the limit of detection for both 8-oxodG and 8-oxodA was 5 fmol. The analysis of calf thymus DNA treated in vitro with methylene blue (ranging from 5 to 200 microM) plus light showed a dose-dependent increase in the levels of both 8-oxodG and 8-oxodA. The level of 8-oxodG was on average 29.4-fold higher than that of 8-oxodA and an excellent linear correlation (r = 0.999) was observed between the two adducts. The influence of different DNA extraction procedures for 8-oxodG and 8-oxodA levels was assessed in DNA extracted from rat livers following dosing with carbon tetrachloride. The levels of 8-oxodG and 8-oxodA were on average 2.9 (p = 0.018) and 1.4 (p = 0.018) times higher, respectively, in DNA samples extracted using an anion-exchange column procedure than in samples extracted using a chaotropic procedure, implying artefactual generation of the two adducts. In conclusion, the online column-switching LC/MS/MS SRM method provides the advantages of increased sample throughput with reduced matrix effects and concomitant ionisation suppression, making the method ideally suited when used in conjunction with chaotropic DNA extraction for the determination of oxidative DNA damage.
first_indexed 2024-03-07T03:25:40Z
format Journal article
id oxford-uuid:b8f09317-5b8c-463c-bc7d-6204481f28f5
institution University of Oxford
language English
last_indexed 2024-03-07T03:25:40Z
publishDate 2009
record_format dspace
spelling oxford-uuid:b8f09317-5b8c-463c-bc7d-6204481f28f52022-03-27T04:59:29ZSimultaneous determination of 8-oxo-2'-deoxyguanosine and 8-oxo-2'-deoxyadenosine in DNA using online column-switching liquid chromatography/tandem mass spectrometry.Journal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:b8f09317-5b8c-463c-bc7d-6204481f28f5EnglishSymplectic Elements at Oxford2009Singh, RTeichert, FVerschoyle, RKaur, BVives, MSharma, RSteward, WGescher, AFarmer, PSensitive and reliable methods are required for the assessment of oxidative DNA damage, which can result from reactive oxygen species that are generated endogenously from cellular metabolism and inflammatory responses, or by exposure to exogenous agents. The development of a liquid chromatography/tandem mass spectrometry (LC/MS/MS) selected reaction monitoring (SRM) method is described, that utilises online column-switching valve technology for the simultaneous determination of two DNA adduct biomarkers of oxidative stress, 8-oxo-7,8-dihydro-2'-deoxyguanosine (8-oxodG) and 8-oxo-7,8-dihydro-2'-deoxyadenosine (8-oxodA). To allow for the accurate quantitation of both adducts the corresponding [(15)N(5)]-labelled stable isotope internal standards were synthesised and added prior to enzymatic hydrolysis of the DNA samples to 2'-deoxynucleosides. The method required between 10 and 40 microg of hydrolysed DNA on-column for the analysis and the limit of detection for both 8-oxodG and 8-oxodA was 5 fmol. The analysis of calf thymus DNA treated in vitro with methylene blue (ranging from 5 to 200 microM) plus light showed a dose-dependent increase in the levels of both 8-oxodG and 8-oxodA. The level of 8-oxodG was on average 29.4-fold higher than that of 8-oxodA and an excellent linear correlation (r = 0.999) was observed between the two adducts. The influence of different DNA extraction procedures for 8-oxodG and 8-oxodA levels was assessed in DNA extracted from rat livers following dosing with carbon tetrachloride. The levels of 8-oxodG and 8-oxodA were on average 2.9 (p = 0.018) and 1.4 (p = 0.018) times higher, respectively, in DNA samples extracted using an anion-exchange column procedure than in samples extracted using a chaotropic procedure, implying artefactual generation of the two adducts. In conclusion, the online column-switching LC/MS/MS SRM method provides the advantages of increased sample throughput with reduced matrix effects and concomitant ionisation suppression, making the method ideally suited when used in conjunction with chaotropic DNA extraction for the determination of oxidative DNA damage.
spellingShingle Singh, R
Teichert, F
Verschoyle, R
Kaur, B
Vives, M
Sharma, R
Steward, W
Gescher, A
Farmer, P
Simultaneous determination of 8-oxo-2'-deoxyguanosine and 8-oxo-2'-deoxyadenosine in DNA using online column-switching liquid chromatography/tandem mass spectrometry.
title Simultaneous determination of 8-oxo-2'-deoxyguanosine and 8-oxo-2'-deoxyadenosine in DNA using online column-switching liquid chromatography/tandem mass spectrometry.
title_full Simultaneous determination of 8-oxo-2'-deoxyguanosine and 8-oxo-2'-deoxyadenosine in DNA using online column-switching liquid chromatography/tandem mass spectrometry.
title_fullStr Simultaneous determination of 8-oxo-2'-deoxyguanosine and 8-oxo-2'-deoxyadenosine in DNA using online column-switching liquid chromatography/tandem mass spectrometry.
title_full_unstemmed Simultaneous determination of 8-oxo-2'-deoxyguanosine and 8-oxo-2'-deoxyadenosine in DNA using online column-switching liquid chromatography/tandem mass spectrometry.
title_short Simultaneous determination of 8-oxo-2'-deoxyguanosine and 8-oxo-2'-deoxyadenosine in DNA using online column-switching liquid chromatography/tandem mass spectrometry.
title_sort simultaneous determination of 8 oxo 2 deoxyguanosine and 8 oxo 2 deoxyadenosine in dna using online column switching liquid chromatography tandem mass spectrometry
work_keys_str_mv AT singhr simultaneousdeterminationof8oxo2deoxyguanosineand8oxo2deoxyadenosineindnausingonlinecolumnswitchingliquidchromatographytandemmassspectrometry
AT teichertf simultaneousdeterminationof8oxo2deoxyguanosineand8oxo2deoxyadenosineindnausingonlinecolumnswitchingliquidchromatographytandemmassspectrometry
AT verschoyler simultaneousdeterminationof8oxo2deoxyguanosineand8oxo2deoxyadenosineindnausingonlinecolumnswitchingliquidchromatographytandemmassspectrometry
AT kaurb simultaneousdeterminationof8oxo2deoxyguanosineand8oxo2deoxyadenosineindnausingonlinecolumnswitchingliquidchromatographytandemmassspectrometry
AT vivesm simultaneousdeterminationof8oxo2deoxyguanosineand8oxo2deoxyadenosineindnausingonlinecolumnswitchingliquidchromatographytandemmassspectrometry
AT sharmar simultaneousdeterminationof8oxo2deoxyguanosineand8oxo2deoxyadenosineindnausingonlinecolumnswitchingliquidchromatographytandemmassspectrometry
AT stewardw simultaneousdeterminationof8oxo2deoxyguanosineand8oxo2deoxyadenosineindnausingonlinecolumnswitchingliquidchromatographytandemmassspectrometry
AT geschera simultaneousdeterminationof8oxo2deoxyguanosineand8oxo2deoxyadenosineindnausingonlinecolumnswitchingliquidchromatographytandemmassspectrometry
AT farmerp simultaneousdeterminationof8oxo2deoxyguanosineand8oxo2deoxyadenosineindnausingonlinecolumnswitchingliquidchromatographytandemmassspectrometry