A prospective case series for a minimally invasive internal fixation device for anterior pelvic ring fractures
<h4>Background</h4> <p>External fixation is commonly used as a means of definitive fixation of pelvic fractures. Pin site infection is common, with some cases of osteomyelitis and inpatient nursing can be challenging. The aim of this study is to report the outcomes and complicatio...
Asıl Yazarlar: | Hoskins, W, Bucknill, A, Wong, J, Britton, E, Judson, R, Gumm, K, Santos, R, Sheehy, R, Griffin, X |
---|---|
Materyal Türü: | Journal article |
Dil: | English |
Baskı/Yayın Bilgisi: |
BioMed Central
2017
|
Benzer Materyaller
-
Conventional plate fixation versus minimally invasive modified pedicle screw-rod fixation for anterior pelvic ring fractures.
Yazar:: Yao-Tung Tsai, ve diğerleri
Baskı/Yayın Bilgisi: (2019-01-01) -
Modified pedicle screw–rod fixation as a minimally invasive treatment for anterior pelvic ring injuries: an initial case series
Yazar:: Xiaotian Wu, ve diğerleri
Baskı/Yayın Bilgisi: (2017-06-01) -
Minimally invasive spinopelvic “crab-shaped fixation” for unstable pelvic ring fractures: technical note and 16 case series
Yazar:: Akinori Okuda, ve diğerleri
Baskı/Yayın Bilgisi: (2019-02-01) -
Minimally invasive internal fixation for unstable pelvic ring fractures: a retrospective study of 27 cases
Yazar:: Shuang Wu, ve diğerleri
Baskı/Yayın Bilgisi: (2021-05-01) -
Modified pedicle screw-rod fixation versus anterior pelvic external fixation for the management of anterior pelvic ring fractures: a comparative study
Yazar:: Chun Bi, ve diğerleri
Baskı/Yayın Bilgisi: (2017-12-01)