Cross-calibration of dual-energy X-ray densitometers for a large, multi-center genetic study of osteoporosis.

Osteoporosis is a common disease with a strong genetic component characterized by reduced bone mass and an increased risk of fragility fractures. Bone mineral density (BMD) is the most important determinant of osteoporotic fracture risk, but the genes responsible for BMD regulation and fracture are...

Full description

Bibliographic Details
Main Authors: Reid, D, Mackay, I, Wilkinson, S, Miller, C, Schuette, D, Compston, J, Cooper, C, Duncan, E, Galwey, N, Keen, R, Langdahl, B, McLellan, A, Pols, H, Uitterlinden, A, O'Riordan, J, Wass, J, Ralston, S, Bennett, S
Format: Journal article
Language:English
Published: 2006
_version_ 1797091791449620480
author Reid, D
Mackay, I
Wilkinson, S
Miller, C
Schuette, D
Compston, J
Cooper, C
Duncan, E
Galwey, N
Keen, R
Langdahl, B
McLellan, A
Pols, H
Uitterlinden, A
O'Riordan, J
Wass, J
Ralston, S
Bennett, S
author_facet Reid, D
Mackay, I
Wilkinson, S
Miller, C
Schuette, D
Compston, J
Cooper, C
Duncan, E
Galwey, N
Keen, R
Langdahl, B
McLellan, A
Pols, H
Uitterlinden, A
O'Riordan, J
Wass, J
Ralston, S
Bennett, S
author_sort Reid, D
collection OXFORD
description Osteoporosis is a common disease with a strong genetic component characterized by reduced bone mass and an increased risk of fragility fractures. Bone mineral density (BMD) is the most important determinant of osteoporotic fracture risk, but the genes responsible for BMD regulation and fracture are incompletely defined. To enable multi-center studies to examine the genetic influences on BMD there is a requirement to standardize measurements across different manufacturers of bone densitometers, different versions of machines and different normative ranges. This paper describes a method developed to allow near-identical subjects with low age-adjusted BMD (based on Z-scores) to be recruited in 17 centers using 27 different densitometers. Cross-calibration was based on measurements using a European spine phantom circulated to all centers and measured ten times on each individual machine. From theses values an individual exponential curve, based on nominal versus observed BMD, was derived for each machine. As expected, there were large and significant variations in nominal BMD values, not only between scanners from different manufacturers but also between different versions of scanners from the same manufacturer. Hologic scanners tended to underestimate the nominal BMD, while Lunar scanners overestimated the value. Norland scanners gave mixed values over estimating BMD at the lower nominal value (0.5 g/cm2) while underestimating the value at the higher value (1.5 g/cm2). The validity of the exponential equations was tested using hip and spine measurements on 991 non-proband women from a familial osteoporosis study (FAMOS). After cross-calibration there was a considerable reduction in variation between machines. This observation, coupled with the absence of a similar reduction in variation attributable to a linear regression on age, demonstrated the validity of the cross-calibration approach. Use of the cross-calibration curves along with a standard normative range (in the case of this study, the Hologic normative range) allowed age-specific Z-scores to be used as an inclusion criterion in this genetic study, a method that will be useful for other trials where age-specific BMD inclusion criteria are required.
first_indexed 2024-03-07T03:37:34Z
format Journal article
id oxford-uuid:bccd7969-23f9-4da6-a88b-86ac611f68d7
institution University of Oxford
language English
last_indexed 2024-03-07T03:37:34Z
publishDate 2006
record_format dspace
spelling oxford-uuid:bccd7969-23f9-4da6-a88b-86ac611f68d72022-03-27T05:27:11ZCross-calibration of dual-energy X-ray densitometers for a large, multi-center genetic study of osteoporosis.Journal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:bccd7969-23f9-4da6-a88b-86ac611f68d7EnglishSymplectic Elements at Oxford2006Reid, DMackay, IWilkinson, SMiller, CSchuette, DCompston, JCooper, CDuncan, EGalwey, NKeen, RLangdahl, BMcLellan, APols, HUitterlinden, AO'Riordan, JWass, JRalston, SBennett, SOsteoporosis is a common disease with a strong genetic component characterized by reduced bone mass and an increased risk of fragility fractures. Bone mineral density (BMD) is the most important determinant of osteoporotic fracture risk, but the genes responsible for BMD regulation and fracture are incompletely defined. To enable multi-center studies to examine the genetic influences on BMD there is a requirement to standardize measurements across different manufacturers of bone densitometers, different versions of machines and different normative ranges. This paper describes a method developed to allow near-identical subjects with low age-adjusted BMD (based on Z-scores) to be recruited in 17 centers using 27 different densitometers. Cross-calibration was based on measurements using a European spine phantom circulated to all centers and measured ten times on each individual machine. From theses values an individual exponential curve, based on nominal versus observed BMD, was derived for each machine. As expected, there were large and significant variations in nominal BMD values, not only between scanners from different manufacturers but also between different versions of scanners from the same manufacturer. Hologic scanners tended to underestimate the nominal BMD, while Lunar scanners overestimated the value. Norland scanners gave mixed values over estimating BMD at the lower nominal value (0.5 g/cm2) while underestimating the value at the higher value (1.5 g/cm2). The validity of the exponential equations was tested using hip and spine measurements on 991 non-proband women from a familial osteoporosis study (FAMOS). After cross-calibration there was a considerable reduction in variation between machines. This observation, coupled with the absence of a similar reduction in variation attributable to a linear regression on age, demonstrated the validity of the cross-calibration approach. Use of the cross-calibration curves along with a standard normative range (in the case of this study, the Hologic normative range) allowed age-specific Z-scores to be used as an inclusion criterion in this genetic study, a method that will be useful for other trials where age-specific BMD inclusion criteria are required.
spellingShingle Reid, D
Mackay, I
Wilkinson, S
Miller, C
Schuette, D
Compston, J
Cooper, C
Duncan, E
Galwey, N
Keen, R
Langdahl, B
McLellan, A
Pols, H
Uitterlinden, A
O'Riordan, J
Wass, J
Ralston, S
Bennett, S
Cross-calibration of dual-energy X-ray densitometers for a large, multi-center genetic study of osteoporosis.
title Cross-calibration of dual-energy X-ray densitometers for a large, multi-center genetic study of osteoporosis.
title_full Cross-calibration of dual-energy X-ray densitometers for a large, multi-center genetic study of osteoporosis.
title_fullStr Cross-calibration of dual-energy X-ray densitometers for a large, multi-center genetic study of osteoporosis.
title_full_unstemmed Cross-calibration of dual-energy X-ray densitometers for a large, multi-center genetic study of osteoporosis.
title_short Cross-calibration of dual-energy X-ray densitometers for a large, multi-center genetic study of osteoporosis.
title_sort cross calibration of dual energy x ray densitometers for a large multi center genetic study of osteoporosis
work_keys_str_mv AT reidd crosscalibrationofdualenergyxraydensitometersforalargemulticentergeneticstudyofosteoporosis
AT mackayi crosscalibrationofdualenergyxraydensitometersforalargemulticentergeneticstudyofosteoporosis
AT wilkinsons crosscalibrationofdualenergyxraydensitometersforalargemulticentergeneticstudyofosteoporosis
AT millerc crosscalibrationofdualenergyxraydensitometersforalargemulticentergeneticstudyofosteoporosis
AT schuetted crosscalibrationofdualenergyxraydensitometersforalargemulticentergeneticstudyofosteoporosis
AT compstonj crosscalibrationofdualenergyxraydensitometersforalargemulticentergeneticstudyofosteoporosis
AT cooperc crosscalibrationofdualenergyxraydensitometersforalargemulticentergeneticstudyofosteoporosis
AT duncane crosscalibrationofdualenergyxraydensitometersforalargemulticentergeneticstudyofosteoporosis
AT galweyn crosscalibrationofdualenergyxraydensitometersforalargemulticentergeneticstudyofosteoporosis
AT keenr crosscalibrationofdualenergyxraydensitometersforalargemulticentergeneticstudyofosteoporosis
AT langdahlb crosscalibrationofdualenergyxraydensitometersforalargemulticentergeneticstudyofosteoporosis
AT mclellana crosscalibrationofdualenergyxraydensitometersforalargemulticentergeneticstudyofosteoporosis
AT polsh crosscalibrationofdualenergyxraydensitometersforalargemulticentergeneticstudyofosteoporosis
AT uitterlindena crosscalibrationofdualenergyxraydensitometersforalargemulticentergeneticstudyofosteoporosis
AT oriordanj crosscalibrationofdualenergyxraydensitometersforalargemulticentergeneticstudyofosteoporosis
AT wassj crosscalibrationofdualenergyxraydensitometersforalargemulticentergeneticstudyofosteoporosis
AT ralstons crosscalibrationofdualenergyxraydensitometersforalargemulticentergeneticstudyofosteoporosis
AT bennetts crosscalibrationofdualenergyxraydensitometersforalargemulticentergeneticstudyofosteoporosis