Comparison of the peripheral blood eosinophil count using near-patient testing and standard automated laboratory measurement in healthy, asthmatic and COPD subjects

Near-patient testing (NPT) allows clinical decisions to be made in a rapid and convenient manner and is often cost effective. In COPD the peripheral blood eosinophil count has been demonstrated to have utility in providing prognostic information and predicting response to treatment during an acute e...

Ausführliche Beschreibung

Bibliographische Detailangaben
Hauptverfasser: Hambleton, K, Connolly, C, Borg, C, Davies, J, Jeffers, H, Russell, R, Bafadhel, M
Format: Journal article
Veröffentlicht: Dove Press 2017
_version_ 1826294660367122432
author Hambleton, K
Connolly, C
Borg, C
Davies, J
Jeffers, H
Russell, R
Bafadhel, M
author_facet Hambleton, K
Connolly, C
Borg, C
Davies, J
Jeffers, H
Russell, R
Bafadhel, M
author_sort Hambleton, K
collection OXFORD
description Near-patient testing (NPT) allows clinical decisions to be made in a rapid and convenient manner and is often cost effective. In COPD the peripheral blood eosinophil count has been demonstrated to have utility in providing prognostic information and predicting response to treatment during an acute exacerbation. For this potential to be achieved having a reliable NPT of blood eosinophil count would be extremely useful. Therefore, we investigated the use of the HemoCue® WBC Diff System and evaluated its sensitivity and specificity in healthy, asthmatic and COPD subjects. This method requires a simple skin prick of blood and was compared to standard venepuncture laboratory analysis. The HemoCue® WBC Diff System measured the peripheral blood eosinophil count in healthy, asthma and COPD subjects with very close correlation to the eosinophil count as measured by standard venepuncture. The correlations were unaffected by disease status. This method for the measurement of the peripheral blood eosinophil count has the potential to provide rapid near-patient results and thus influence the speed of management decisions in the treatment of airway diseases.
first_indexed 2024-03-07T03:49:07Z
format Journal article
id oxford-uuid:c099e511-dd83-41b1-a32f-c1ddfdaf958f
institution University of Oxford
last_indexed 2024-03-07T03:49:07Z
publishDate 2017
publisher Dove Press
record_format dspace
spelling oxford-uuid:c099e511-dd83-41b1-a32f-c1ddfdaf958f2022-03-27T05:55:30ZComparison of the peripheral blood eosinophil count using near-patient testing and standard automated laboratory measurement in healthy, asthmatic and COPD subjectsJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:c099e511-dd83-41b1-a32f-c1ddfdaf958fSymplectic Elements at OxfordDove Press2017Hambleton, KConnolly, CBorg, CDavies, JJeffers, HRussell, RBafadhel, MNear-patient testing (NPT) allows clinical decisions to be made in a rapid and convenient manner and is often cost effective. In COPD the peripheral blood eosinophil count has been demonstrated to have utility in providing prognostic information and predicting response to treatment during an acute exacerbation. For this potential to be achieved having a reliable NPT of blood eosinophil count would be extremely useful. Therefore, we investigated the use of the HemoCue® WBC Diff System and evaluated its sensitivity and specificity in healthy, asthmatic and COPD subjects. This method requires a simple skin prick of blood and was compared to standard venepuncture laboratory analysis. The HemoCue® WBC Diff System measured the peripheral blood eosinophil count in healthy, asthma and COPD subjects with very close correlation to the eosinophil count as measured by standard venepuncture. The correlations were unaffected by disease status. This method for the measurement of the peripheral blood eosinophil count has the potential to provide rapid near-patient results and thus influence the speed of management decisions in the treatment of airway diseases.
spellingShingle Hambleton, K
Connolly, C
Borg, C
Davies, J
Jeffers, H
Russell, R
Bafadhel, M
Comparison of the peripheral blood eosinophil count using near-patient testing and standard automated laboratory measurement in healthy, asthmatic and COPD subjects
title Comparison of the peripheral blood eosinophil count using near-patient testing and standard automated laboratory measurement in healthy, asthmatic and COPD subjects
title_full Comparison of the peripheral blood eosinophil count using near-patient testing and standard automated laboratory measurement in healthy, asthmatic and COPD subjects
title_fullStr Comparison of the peripheral blood eosinophil count using near-patient testing and standard automated laboratory measurement in healthy, asthmatic and COPD subjects
title_full_unstemmed Comparison of the peripheral blood eosinophil count using near-patient testing and standard automated laboratory measurement in healthy, asthmatic and COPD subjects
title_short Comparison of the peripheral blood eosinophil count using near-patient testing and standard automated laboratory measurement in healthy, asthmatic and COPD subjects
title_sort comparison of the peripheral blood eosinophil count using near patient testing and standard automated laboratory measurement in healthy asthmatic and copd subjects
work_keys_str_mv AT hambletonk comparisonoftheperipheralbloodeosinophilcountusingnearpatienttestingandstandardautomatedlaboratorymeasurementinhealthyasthmaticandcopdsubjects
AT connollyc comparisonoftheperipheralbloodeosinophilcountusingnearpatienttestingandstandardautomatedlaboratorymeasurementinhealthyasthmaticandcopdsubjects
AT borgc comparisonoftheperipheralbloodeosinophilcountusingnearpatienttestingandstandardautomatedlaboratorymeasurementinhealthyasthmaticandcopdsubjects
AT daviesj comparisonoftheperipheralbloodeosinophilcountusingnearpatienttestingandstandardautomatedlaboratorymeasurementinhealthyasthmaticandcopdsubjects
AT jeffersh comparisonoftheperipheralbloodeosinophilcountusingnearpatienttestingandstandardautomatedlaboratorymeasurementinhealthyasthmaticandcopdsubjects
AT russellr comparisonoftheperipheralbloodeosinophilcountusingnearpatienttestingandstandardautomatedlaboratorymeasurementinhealthyasthmaticandcopdsubjects
AT bafadhelm comparisonoftheperipheralbloodeosinophilcountusingnearpatienttestingandstandardautomatedlaboratorymeasurementinhealthyasthmaticandcopdsubjects