Use of combined Shewhart-CUSUM control charts in internal quality control of enzyme-linked immunosorbent assays for the typing of foot and mouth disease virus antigen.
An enzyme-linked immunosorbent assay (ELISA) for the typing of foot and mouth disease virus (FMDV) antigen was employed for the routine laboratory diagnosis of FMD at a regional veterinary laboratory in northern Thailand. An objective procedure was developed to monitor the test performance of the EL...
Main Authors: | , , , |
---|---|
Format: | Journal article |
Language: | English |
Published: |
1994
|
_version_ | 1797092740053336064 |
---|---|
author | Blacksell, S Gleeson, L Lunt, R Chamnanpood, C |
author_facet | Blacksell, S Gleeson, L Lunt, R Chamnanpood, C |
author_sort | Blacksell, S |
collection | OXFORD |
description | An enzyme-linked immunosorbent assay (ELISA) for the typing of foot and mouth disease virus (FMDV) antigen was employed for the routine laboratory diagnosis of FMD at a regional veterinary laboratory in northern Thailand. An objective procedure was developed to monitor the test performance of the ELISA, using absolute test control limits in a Shewhart-CUSUM (cumulative sum) control chart method. The procedure detected significant data trends and 'beyond control limit' situations for each antigen typing system (types O, A and Asia 1), using an assay variable (gamma i). Retrospective analysis using Shewhart-CUSUM control charts of data from 42 ELISAs demonstrated that control limits were exceeded in two assays for FMDV type A. The Shewhart-CUSUM control chart is a simple and reliable internal quality control method for the detection of significant random and systematic variation in assays. |
first_indexed | 2024-03-07T03:50:19Z |
format | Journal article |
id | oxford-uuid:c1038bfd-4dc6-4bb6-a632-0642a4fd7a5f |
institution | University of Oxford |
language | English |
last_indexed | 2024-03-07T03:50:19Z |
publishDate | 1994 |
record_format | dspace |
spelling | oxford-uuid:c1038bfd-4dc6-4bb6-a632-0642a4fd7a5f2022-03-27T05:58:27ZUse of combined Shewhart-CUSUM control charts in internal quality control of enzyme-linked immunosorbent assays for the typing of foot and mouth disease virus antigen.Journal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:c1038bfd-4dc6-4bb6-a632-0642a4fd7a5fEnglishSymplectic Elements at Oxford1994Blacksell, SGleeson, LLunt, RChamnanpood, CAn enzyme-linked immunosorbent assay (ELISA) for the typing of foot and mouth disease virus (FMDV) antigen was employed for the routine laboratory diagnosis of FMD at a regional veterinary laboratory in northern Thailand. An objective procedure was developed to monitor the test performance of the ELISA, using absolute test control limits in a Shewhart-CUSUM (cumulative sum) control chart method. The procedure detected significant data trends and 'beyond control limit' situations for each antigen typing system (types O, A and Asia 1), using an assay variable (gamma i). Retrospective analysis using Shewhart-CUSUM control charts of data from 42 ELISAs demonstrated that control limits were exceeded in two assays for FMDV type A. The Shewhart-CUSUM control chart is a simple and reliable internal quality control method for the detection of significant random and systematic variation in assays. |
spellingShingle | Blacksell, S Gleeson, L Lunt, R Chamnanpood, C Use of combined Shewhart-CUSUM control charts in internal quality control of enzyme-linked immunosorbent assays for the typing of foot and mouth disease virus antigen. |
title | Use of combined Shewhart-CUSUM control charts in internal quality control of enzyme-linked immunosorbent assays for the typing of foot and mouth disease virus antigen. |
title_full | Use of combined Shewhart-CUSUM control charts in internal quality control of enzyme-linked immunosorbent assays for the typing of foot and mouth disease virus antigen. |
title_fullStr | Use of combined Shewhart-CUSUM control charts in internal quality control of enzyme-linked immunosorbent assays for the typing of foot and mouth disease virus antigen. |
title_full_unstemmed | Use of combined Shewhart-CUSUM control charts in internal quality control of enzyme-linked immunosorbent assays for the typing of foot and mouth disease virus antigen. |
title_short | Use of combined Shewhart-CUSUM control charts in internal quality control of enzyme-linked immunosorbent assays for the typing of foot and mouth disease virus antigen. |
title_sort | use of combined shewhart cusum control charts in internal quality control of enzyme linked immunosorbent assays for the typing of foot and mouth disease virus antigen |
work_keys_str_mv | AT blacksells useofcombinedshewhartcusumcontrolchartsininternalqualitycontrolofenzymelinkedimmunosorbentassaysforthetypingoffootandmouthdiseasevirusantigen AT gleesonl useofcombinedshewhartcusumcontrolchartsininternalqualitycontrolofenzymelinkedimmunosorbentassaysforthetypingoffootandmouthdiseasevirusantigen AT luntr useofcombinedshewhartcusumcontrolchartsininternalqualitycontrolofenzymelinkedimmunosorbentassaysforthetypingoffootandmouthdiseasevirusantigen AT chamnanpoodc useofcombinedshewhartcusumcontrolchartsininternalqualitycontrolofenzymelinkedimmunosorbentassaysforthetypingoffootandmouthdiseasevirusantigen |