Non-invasive stroke volume estimation by transthoracic electrical bioimpedance versus Doppler echocardiography in healthy volunteers

Thoracic electrical bioimpedance (TEB) and transthoracic echocardiography (TTE) are non-invasive methods to estimate stroke volume (SV) and cardiac output (CO). Thoracic electrical bioimpedance is not in widespread clinical use with reports of inaccurate cardiac output estimation compared to invasiv...

Full description

Bibliographic Details
Main Authors: Harford, M, Clark, S, Smythe, J, Gerry, S, Villarroel, M, Jorge, J, Chaichulee, S, Tarassenko, L, Young, J, Watkinson, P
Format: Journal article
Published: Taylor and Francis 2019
_version_ 1826294862248411136
author Harford, M
Clark, S
Smythe, J
Gerry, S
Villarroel, M
Jorge, J
Chaichulee, S
Tarassenko, L
Young, J
Watkinson, P
author_facet Harford, M
Clark, S
Smythe, J
Gerry, S
Villarroel, M
Jorge, J
Chaichulee, S
Tarassenko, L
Young, J
Watkinson, P
author_sort Harford, M
collection OXFORD
description Thoracic electrical bioimpedance (TEB) and transthoracic echocardiography (TTE) are non-invasive methods to estimate stroke volume (SV) and cardiac output (CO). Thoracic electrical bioimpedance is not in widespread clinical use with reports of inaccurate cardiac output estimation compared to invasive monitors, particularly in non-healthy populations. We explore its use as a trend monitor by comparing it against thoracic echocardiography in fifteen healthy volunteers undergoing two physical challenges designed to vary cardiac output. Of all paired values, 54.6% showed gross trend agreement and only 1.9% showed direct disagreement between the two monitors. Our results show thoracic bioimpedance may have a role as a non-invasive cardiac output trend monitor in healthy volunteer studies.
first_indexed 2024-03-07T03:52:13Z
format Journal article
id oxford-uuid:c1aa708b-18ff-4cb4-9582-f63dccccf009
institution University of Oxford
last_indexed 2024-03-07T03:52:13Z
publishDate 2019
publisher Taylor and Francis
record_format dspace
spelling oxford-uuid:c1aa708b-18ff-4cb4-9582-f63dccccf0092022-03-27T06:03:12ZNon-invasive stroke volume estimation by transthoracic electrical bioimpedance versus Doppler echocardiography in healthy volunteersJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:c1aa708b-18ff-4cb4-9582-f63dccccf009Symplectic Elements at OxfordTaylor and Francis2019Harford, MClark, SSmythe, JGerry, SVillarroel, MJorge, JChaichulee, STarassenko, LYoung, JWatkinson, PThoracic electrical bioimpedance (TEB) and transthoracic echocardiography (TTE) are non-invasive methods to estimate stroke volume (SV) and cardiac output (CO). Thoracic electrical bioimpedance is not in widespread clinical use with reports of inaccurate cardiac output estimation compared to invasive monitors, particularly in non-healthy populations. We explore its use as a trend monitor by comparing it against thoracic echocardiography in fifteen healthy volunteers undergoing two physical challenges designed to vary cardiac output. Of all paired values, 54.6% showed gross trend agreement and only 1.9% showed direct disagreement between the two monitors. Our results show thoracic bioimpedance may have a role as a non-invasive cardiac output trend monitor in healthy volunteer studies.
spellingShingle Harford, M
Clark, S
Smythe, J
Gerry, S
Villarroel, M
Jorge, J
Chaichulee, S
Tarassenko, L
Young, J
Watkinson, P
Non-invasive stroke volume estimation by transthoracic electrical bioimpedance versus Doppler echocardiography in healthy volunteers
title Non-invasive stroke volume estimation by transthoracic electrical bioimpedance versus Doppler echocardiography in healthy volunteers
title_full Non-invasive stroke volume estimation by transthoracic electrical bioimpedance versus Doppler echocardiography in healthy volunteers
title_fullStr Non-invasive stroke volume estimation by transthoracic electrical bioimpedance versus Doppler echocardiography in healthy volunteers
title_full_unstemmed Non-invasive stroke volume estimation by transthoracic electrical bioimpedance versus Doppler echocardiography in healthy volunteers
title_short Non-invasive stroke volume estimation by transthoracic electrical bioimpedance versus Doppler echocardiography in healthy volunteers
title_sort non invasive stroke volume estimation by transthoracic electrical bioimpedance versus doppler echocardiography in healthy volunteers
work_keys_str_mv AT harfordm noninvasivestrokevolumeestimationbytransthoracicelectricalbioimpedanceversusdopplerechocardiographyinhealthyvolunteers
AT clarks noninvasivestrokevolumeestimationbytransthoracicelectricalbioimpedanceversusdopplerechocardiographyinhealthyvolunteers
AT smythej noninvasivestrokevolumeestimationbytransthoracicelectricalbioimpedanceversusdopplerechocardiographyinhealthyvolunteers
AT gerrys noninvasivestrokevolumeestimationbytransthoracicelectricalbioimpedanceversusdopplerechocardiographyinhealthyvolunteers
AT villarroelm noninvasivestrokevolumeestimationbytransthoracicelectricalbioimpedanceversusdopplerechocardiographyinhealthyvolunteers
AT jorgej noninvasivestrokevolumeestimationbytransthoracicelectricalbioimpedanceversusdopplerechocardiographyinhealthyvolunteers
AT chaichulees noninvasivestrokevolumeestimationbytransthoracicelectricalbioimpedanceversusdopplerechocardiographyinhealthyvolunteers
AT tarassenkol noninvasivestrokevolumeestimationbytransthoracicelectricalbioimpedanceversusdopplerechocardiographyinhealthyvolunteers
AT youngj noninvasivestrokevolumeestimationbytransthoracicelectricalbioimpedanceversusdopplerechocardiographyinhealthyvolunteers
AT watkinsonp noninvasivestrokevolumeestimationbytransthoracicelectricalbioimpedanceversusdopplerechocardiographyinhealthyvolunteers