Novel MRI method to detect altered left ventricular ejection and filling patterns in rodent models of disease.

The aim of this study was to determine whether high-temporal-resolution (HTR) cardiac cine-MRI could be used to identify subtle alterations in contractility and diastolic function in rodent models of disease. Following standard 45-min in vivo MRI measurements of left ventricular (LV) volumes, a sing...

Full description

Bibliographic Details
Main Authors: Stuckey, D, Carr, C, Tyler, D, Aasum, E, Clarke, K
Format: Journal article
Language:English
Published: 2008
_version_ 1826294868153991168
author Stuckey, D
Carr, C
Tyler, D
Aasum, E
Clarke, K
author_facet Stuckey, D
Carr, C
Tyler, D
Aasum, E
Clarke, K
author_sort Stuckey, D
collection OXFORD
description The aim of this study was to determine whether high-temporal-resolution (HTR) cardiac cine-MRI could be used to identify subtle alterations in contractility and diastolic function in rodent models of disease. Following standard 45-min in vivo MRI measurements of left ventricular (LV) volumes, a single mid-ventricular slice was selected for 3-min HTR imaging. Cavity volume was measured every 2.4 ms, yielding approximately 60 images through the cardiac cycle. From these images, peak ejection and filling rates were calculated and two separate filling phases (comparable with the early (E) and late (A) phases of a Doppler echocardiogram) were identified during diastole. Repeated HTR imaging of the same animals on sequential days indicated reproducibility of E'/A' ratios of 11%. In chronically infarcted rat hearts, HTR imaging revealed lower peak ejection rates (PERs), peak early filling rates (E') and E'/A' ratios, and higher peak late filling rates (A') than in sham-operated rats. Diabetic db/db mouse hearts had the same function as controls when using standard cine-MRI, yet HTR imaging identified significantly lower PERs, early filling rates and E'/A' ratios in diabetic mouse hearts. In conclusion, the HTR MRI technique revealed changes in function that were below the limits of detection of standard cine-MRI.
first_indexed 2024-03-07T03:52:19Z
format Journal article
id oxford-uuid:c1b0d08a-beb9-4c1f-83c7-bb768347e80b
institution University of Oxford
language English
last_indexed 2024-03-07T03:52:19Z
publishDate 2008
record_format dspace
spelling oxford-uuid:c1b0d08a-beb9-4c1f-83c7-bb768347e80b2022-03-27T06:03:26ZNovel MRI method to detect altered left ventricular ejection and filling patterns in rodent models of disease.Journal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:c1b0d08a-beb9-4c1f-83c7-bb768347e80bEnglishSymplectic Elements at Oxford2008Stuckey, DCarr, CTyler, DAasum, EClarke, KThe aim of this study was to determine whether high-temporal-resolution (HTR) cardiac cine-MRI could be used to identify subtle alterations in contractility and diastolic function in rodent models of disease. Following standard 45-min in vivo MRI measurements of left ventricular (LV) volumes, a single mid-ventricular slice was selected for 3-min HTR imaging. Cavity volume was measured every 2.4 ms, yielding approximately 60 images through the cardiac cycle. From these images, peak ejection and filling rates were calculated and two separate filling phases (comparable with the early (E) and late (A) phases of a Doppler echocardiogram) were identified during diastole. Repeated HTR imaging of the same animals on sequential days indicated reproducibility of E'/A' ratios of 11%. In chronically infarcted rat hearts, HTR imaging revealed lower peak ejection rates (PERs), peak early filling rates (E') and E'/A' ratios, and higher peak late filling rates (A') than in sham-operated rats. Diabetic db/db mouse hearts had the same function as controls when using standard cine-MRI, yet HTR imaging identified significantly lower PERs, early filling rates and E'/A' ratios in diabetic mouse hearts. In conclusion, the HTR MRI technique revealed changes in function that were below the limits of detection of standard cine-MRI.
spellingShingle Stuckey, D
Carr, C
Tyler, D
Aasum, E
Clarke, K
Novel MRI method to detect altered left ventricular ejection and filling patterns in rodent models of disease.
title Novel MRI method to detect altered left ventricular ejection and filling patterns in rodent models of disease.
title_full Novel MRI method to detect altered left ventricular ejection and filling patterns in rodent models of disease.
title_fullStr Novel MRI method to detect altered left ventricular ejection and filling patterns in rodent models of disease.
title_full_unstemmed Novel MRI method to detect altered left ventricular ejection and filling patterns in rodent models of disease.
title_short Novel MRI method to detect altered left ventricular ejection and filling patterns in rodent models of disease.
title_sort novel mri method to detect altered left ventricular ejection and filling patterns in rodent models of disease
work_keys_str_mv AT stuckeyd novelmrimethodtodetectalteredleftventricularejectionandfillingpatternsinrodentmodelsofdisease
AT carrc novelmrimethodtodetectalteredleftventricularejectionandfillingpatternsinrodentmodelsofdisease
AT tylerd novelmrimethodtodetectalteredleftventricularejectionandfillingpatternsinrodentmodelsofdisease
AT aasume novelmrimethodtodetectalteredleftventricularejectionandfillingpatternsinrodentmodelsofdisease
AT clarkek novelmrimethodtodetectalteredleftventricularejectionandfillingpatternsinrodentmodelsofdisease