Measuring Central Retinal Sensitivity Using Microperimetry
Microperimetry is an increasingly often used method of assessing the sensitivity of the central macula, analyzing fixation capabilities and loci, and accurately combining structural and functional information, even in the absence of stable fixation. Ongoing gene therapy trials have targeted the cent...
Main Authors: | , , |
---|---|
Format: | Book section |
Published: |
Springer
2017
|
_version_ | 1797092880738680832 |
---|---|
author | Talib, M Jolly, J Boon, C |
author2 | Boon, C |
author_facet | Boon, C Talib, M Jolly, J Boon, C |
author_sort | Talib, M |
collection | OXFORD |
description | Microperimetry is an increasingly often used method of assessing the sensitivity of the central macula, analyzing fixation capabilities and loci, and accurately combining structural and functional information, even in the absence of stable fixation. Ongoing gene therapy trials have targeted the central retina, and utilized microperimetry as a main outcome measure for changes in retinal function. In retinal treatment planning, microperimetry has been used to assess the potential therapeutic window of opportunity. In the following pages, we briefly review the necessary steps to perform the Macular Integrity Assessment (MAIA) microperimetry. |
first_indexed | 2024-03-07T03:52:20Z |
format | Book section |
id | oxford-uuid:c1b30c74-24e6-4384-8a2e-af1da93aebd7 |
institution | University of Oxford |
last_indexed | 2024-03-07T03:52:20Z |
publishDate | 2017 |
publisher | Springer |
record_format | dspace |
spelling | oxford-uuid:c1b30c74-24e6-4384-8a2e-af1da93aebd72022-03-27T06:03:28ZMeasuring Central Retinal Sensitivity Using MicroperimetryBook sectionhttp://purl.org/coar/resource_type/c_3248uuid:c1b30c74-24e6-4384-8a2e-af1da93aebd7Symplectic Elements at OxfordSpringer2017Talib, MJolly, JBoon, CBoon, CWijnholds, JMicroperimetry is an increasingly often used method of assessing the sensitivity of the central macula, analyzing fixation capabilities and loci, and accurately combining structural and functional information, even in the absence of stable fixation. Ongoing gene therapy trials have targeted the central retina, and utilized microperimetry as a main outcome measure for changes in retinal function. In retinal treatment planning, microperimetry has been used to assess the potential therapeutic window of opportunity. In the following pages, we briefly review the necessary steps to perform the Macular Integrity Assessment (MAIA) microperimetry. |
spellingShingle | Talib, M Jolly, J Boon, C Measuring Central Retinal Sensitivity Using Microperimetry |
title | Measuring Central Retinal Sensitivity Using Microperimetry |
title_full | Measuring Central Retinal Sensitivity Using Microperimetry |
title_fullStr | Measuring Central Retinal Sensitivity Using Microperimetry |
title_full_unstemmed | Measuring Central Retinal Sensitivity Using Microperimetry |
title_short | Measuring Central Retinal Sensitivity Using Microperimetry |
title_sort | measuring central retinal sensitivity using microperimetry |
work_keys_str_mv | AT talibm measuringcentralretinalsensitivityusingmicroperimetry AT jollyj measuringcentralretinalsensitivityusingmicroperimetry AT boonc measuringcentralretinalsensitivityusingmicroperimetry |