Optimized saturation pulse train for human first-pass myocardial perfusion imaging at 7T

To investigate whether saturation using existing methods developed for 3T imaging is feasible for clinical perfusion imaging at 7T, and to propose a new design of saturation pulse train for first-pass myocardial perfusion imaging at 7T.The new design of saturation pulse train consists of four hyperb...

Full description

Bibliographic Details
Main Authors: Tao, Y, Hess, A, Keith, G, Rodgers, C, Liu, A, Francis, J, Neubauer, S, Robson, M
Format: Journal article
Language:English
Published: Wiley 2015
_version_ 1797093046631792640
author Tao, Y
Hess, A
Keith, G
Rodgers, C
Liu, A
Francis, J
Neubauer, S
Robson, M
author_facet Tao, Y
Hess, A
Keith, G
Rodgers, C
Liu, A
Francis, J
Neubauer, S
Robson, M
author_sort Tao, Y
collection OXFORD
description To investigate whether saturation using existing methods developed for 3T imaging is feasible for clinical perfusion imaging at 7T, and to propose a new design of saturation pulse train for first-pass myocardial perfusion imaging at 7T.The new design of saturation pulse train consists of four hyperbolic-secant (HS8) radiofrequency pulses, whose peak amplitudes are optimized for a target range of static and transmit field variations and radiofrequency power deposition restrictions measured in the myocardium at 7T. The proposed method and existing methods were compared in simulation, phantom, and in vivo experiments.In healthy volunteer experiments without contrast agent, average saturation efficiency with the proposed method was 97.8%. This is superior to results from the three previously published methods at 86/95/90.8%. The first series of human first-pass myocardial perfusion images at 7T have been successfully acquired with the proposed method.Existing saturation methods developed for 3T imaging are not optimal for perfusion imaging at 7T. The proposed new design of saturation pulse train can saturate effectively, and with this method first-pass myocardial perfusion imaging is feasible in humans at 7T.
first_indexed 2024-03-07T03:54:44Z
format Journal article
id oxford-uuid:c27c11fb-0996-42d5-8463-89e3213d76aa
institution University of Oxford
language English
last_indexed 2024-03-07T03:54:44Z
publishDate 2015
publisher Wiley
record_format dspace
spelling oxford-uuid:c27c11fb-0996-42d5-8463-89e3213d76aa2022-03-27T06:09:22ZOptimized saturation pulse train for human first-pass myocardial perfusion imaging at 7TJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:c27c11fb-0996-42d5-8463-89e3213d76aaEnglishSymplectic Elements at OxfordWiley2015Tao, YHess, AKeith, GRodgers, CLiu, AFrancis, JNeubauer, SRobson, MTo investigate whether saturation using existing methods developed for 3T imaging is feasible for clinical perfusion imaging at 7T, and to propose a new design of saturation pulse train for first-pass myocardial perfusion imaging at 7T.The new design of saturation pulse train consists of four hyperbolic-secant (HS8) radiofrequency pulses, whose peak amplitudes are optimized for a target range of static and transmit field variations and radiofrequency power deposition restrictions measured in the myocardium at 7T. The proposed method and existing methods were compared in simulation, phantom, and in vivo experiments.In healthy volunteer experiments without contrast agent, average saturation efficiency with the proposed method was 97.8%. This is superior to results from the three previously published methods at 86/95/90.8%. The first series of human first-pass myocardial perfusion images at 7T have been successfully acquired with the proposed method.Existing saturation methods developed for 3T imaging are not optimal for perfusion imaging at 7T. The proposed new design of saturation pulse train can saturate effectively, and with this method first-pass myocardial perfusion imaging is feasible in humans at 7T.
spellingShingle Tao, Y
Hess, A
Keith, G
Rodgers, C
Liu, A
Francis, J
Neubauer, S
Robson, M
Optimized saturation pulse train for human first-pass myocardial perfusion imaging at 7T
title Optimized saturation pulse train for human first-pass myocardial perfusion imaging at 7T
title_full Optimized saturation pulse train for human first-pass myocardial perfusion imaging at 7T
title_fullStr Optimized saturation pulse train for human first-pass myocardial perfusion imaging at 7T
title_full_unstemmed Optimized saturation pulse train for human first-pass myocardial perfusion imaging at 7T
title_short Optimized saturation pulse train for human first-pass myocardial perfusion imaging at 7T
title_sort optimized saturation pulse train for human first pass myocardial perfusion imaging at 7t
work_keys_str_mv AT taoy optimizedsaturationpulsetrainforhumanfirstpassmyocardialperfusionimagingat7t
AT hessa optimizedsaturationpulsetrainforhumanfirstpassmyocardialperfusionimagingat7t
AT keithg optimizedsaturationpulsetrainforhumanfirstpassmyocardialperfusionimagingat7t
AT rodgersc optimizedsaturationpulsetrainforhumanfirstpassmyocardialperfusionimagingat7t
AT liua optimizedsaturationpulsetrainforhumanfirstpassmyocardialperfusionimagingat7t
AT francisj optimizedsaturationpulsetrainforhumanfirstpassmyocardialperfusionimagingat7t
AT neubauers optimizedsaturationpulsetrainforhumanfirstpassmyocardialperfusionimagingat7t
AT robsonm optimizedsaturationpulsetrainforhumanfirstpassmyocardialperfusionimagingat7t