The calibration of the Sudbury Neutrino Observatory using uniformly distributed radioactive sources

The production and analysis of distributed sources of 24Na and 222Rn in the Sudbury Neutrino Observatory (SNO) are described. These unique sources provided accurate calibrations of the response to neutrons, produced through photodisintegration of the deuterons in the heavy water target, and to low e...

Full description

Bibliographic Details
Main Authors: Boudjemline, K, Cai, B, Cleveland, B, Evans, H, Ewan, G, Farine, J, Ford, R, Guillian, E, Hallin, A, Hallman, E, Howard, C, Jagam, P, Jelley, N, Keeter, K, Klein, JR, Kraus, C, Krauss, C, Lange, R, Lawson, I, Leslie, JR, Loach, J, McDonald, AB, McGregor, G, Noble, A, O'Keeffe, H
Format: Journal article
Published: 2009
_version_ 1797093446274514944
author Boudjemline, K
Cai, B
Cleveland, B
Evans, H
Ewan, G
Farine, J
Ford, R
Guillian, E
Hallin, A
Hallman, E
Howard, C
Jagam, P
Jelley, N
Keeter, K
Klein, JR
Kraus, C
Krauss, C
Lange, R
Lawson, I
Leslie, JR
Loach, J
McDonald, AB
McGregor, G
Noble, A
O'Keeffe, H
author_facet Boudjemline, K
Cai, B
Cleveland, B
Evans, H
Ewan, G
Farine, J
Ford, R
Guillian, E
Hallin, A
Hallman, E
Howard, C
Jagam, P
Jelley, N
Keeter, K
Klein, JR
Kraus, C
Krauss, C
Lange, R
Lawson, I
Leslie, JR
Loach, J
McDonald, AB
McGregor, G
Noble, A
O'Keeffe, H
author_sort Boudjemline, K
collection OXFORD
description The production and analysis of distributed sources of 24Na and 222Rn in the Sudbury Neutrino Observatory (SNO) are described. These unique sources provided accurate calibrations of the response to neutrons, produced through photodisintegration of the deuterons in the heavy water target, and to low energy betas and gammas. The application of these sources in determining the neutron detection efficiency and response of the 3He proportional counter array, and the characteristics of background Cherenkov light from trace amounts of natural radioactivity is described.
first_indexed 2024-03-07T04:00:31Z
format Journal article
id oxford-uuid:c46d43e7-2035-40bb-a53b-fd45817fa673
institution University of Oxford
last_indexed 2024-03-07T04:00:31Z
publishDate 2009
record_format dspace
spelling oxford-uuid:c46d43e7-2035-40bb-a53b-fd45817fa6732022-03-27T06:23:21ZThe calibration of the Sudbury Neutrino Observatory using uniformly distributed radioactive sourcesJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:c46d43e7-2035-40bb-a53b-fd45817fa673Symplectic Elements at Oxford2009Boudjemline, KCai, BCleveland, BEvans, HEwan, GFarine, JFord, RGuillian, EHallin, AHallman, EHoward, CJagam, PJelley, NKeeter, KKlein, JRKraus, CKrauss, CLange, RLawson, ILeslie, JRLoach, JMcDonald, ABMcGregor, GNoble, AO'Keeffe, HThe production and analysis of distributed sources of 24Na and 222Rn in the Sudbury Neutrino Observatory (SNO) are described. These unique sources provided accurate calibrations of the response to neutrons, produced through photodisintegration of the deuterons in the heavy water target, and to low energy betas and gammas. The application of these sources in determining the neutron detection efficiency and response of the 3He proportional counter array, and the characteristics of background Cherenkov light from trace amounts of natural radioactivity is described.
spellingShingle Boudjemline, K
Cai, B
Cleveland, B
Evans, H
Ewan, G
Farine, J
Ford, R
Guillian, E
Hallin, A
Hallman, E
Howard, C
Jagam, P
Jelley, N
Keeter, K
Klein, JR
Kraus, C
Krauss, C
Lange, R
Lawson, I
Leslie, JR
Loach, J
McDonald, AB
McGregor, G
Noble, A
O'Keeffe, H
The calibration of the Sudbury Neutrino Observatory using uniformly distributed radioactive sources
title The calibration of the Sudbury Neutrino Observatory using uniformly distributed radioactive sources
title_full The calibration of the Sudbury Neutrino Observatory using uniformly distributed radioactive sources
title_fullStr The calibration of the Sudbury Neutrino Observatory using uniformly distributed radioactive sources
title_full_unstemmed The calibration of the Sudbury Neutrino Observatory using uniformly distributed radioactive sources
title_short The calibration of the Sudbury Neutrino Observatory using uniformly distributed radioactive sources
title_sort calibration of the sudbury neutrino observatory using uniformly distributed radioactive sources
work_keys_str_mv AT boudjemlinek thecalibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT caib thecalibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT clevelandb thecalibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT evansh thecalibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT ewang thecalibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT farinej thecalibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT fordr thecalibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT guilliane thecalibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT hallina thecalibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT hallmane thecalibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT howardc thecalibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT jagamp thecalibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT jelleyn thecalibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT keeterk thecalibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT kleinjr thecalibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT krausc thecalibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT kraussc thecalibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT langer thecalibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT lawsoni thecalibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT lesliejr thecalibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT loachj thecalibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT mcdonaldab thecalibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT mcgregorg thecalibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT noblea thecalibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT okeeffeh thecalibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT boudjemlinek calibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT caib calibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT clevelandb calibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT evansh calibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT ewang calibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT farinej calibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT fordr calibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT guilliane calibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT hallina calibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT hallmane calibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT howardc calibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT jagamp calibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT jelleyn calibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT keeterk calibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT kleinjr calibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT krausc calibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT kraussc calibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT langer calibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT lawsoni calibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT lesliejr calibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT loachj calibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT mcdonaldab calibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT mcgregorg calibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT noblea calibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources
AT okeeffeh calibrationofthesudburyneutrinoobservatoryusinguniformlydistributedradioactivesources