Automated solid-phase extraction method for the determination of atovaquone in capillary blood applied onto sampling paper by rapid high-performance liquid chromatography.

A bioanalytical method for the determination of atovaquone in 100 microl blood-spots by solid-phase extraction and high-performance liquid chromatography has been developed and validated. Atovaquone was extracted from the sampling paper in 0.2 M phosphoric acid and a structurally similar internal st...

Full description

Bibliographic Details
Main Authors: Lindegårth, N, Funding, L, Bergqvist, Y
Format: Journal article
Language:English
Published: 2001
_version_ 1797094817589624832
author Lindegårth, N
Funding, L
Bergqvist, Y
author_facet Lindegårth, N
Funding, L
Bergqvist, Y
author_sort Lindegårth, N
collection OXFORD
description A bioanalytical method for the determination of atovaquone in 100 microl blood-spots by solid-phase extraction and high-performance liquid chromatography has been developed and validated. Atovaquone was extracted from the sampling paper in 0.2 M phosphoric acid and a structurally similar internal standard was added with acetonitrile before being loaded onto a C8 end-capped solid-phase extraction column. Atovaquone and internal standard were analysed by high-performance liquid chromatography on a C18 J'Sphere ODS-M80 (150 x 4.0 mm) column with mobile phase acetonitrile-phosphate buffer, 0.01 M, pH 7.0 (65:35, v/v) and UV detection at 277 nm. The intra-assay precision was 2.7% at 12.00 microM and 13.5% at 1.00 microM. The inter-assay precision was 3.3% at 12.00 microM and 15.6% at 1.00 microM. The lower limit of quantification was 1.00 microM. The limit of detection was 0.50 microM.
first_indexed 2024-03-07T04:19:14Z
format Journal article
id oxford-uuid:ca73c6b1-fbdf-4f2e-820b-388ac66a4e1a
institution University of Oxford
language English
last_indexed 2024-03-07T04:19:14Z
publishDate 2001
record_format dspace
spelling oxford-uuid:ca73c6b1-fbdf-4f2e-820b-388ac66a4e1a2022-03-27T07:07:30ZAutomated solid-phase extraction method for the determination of atovaquone in capillary blood applied onto sampling paper by rapid high-performance liquid chromatography.Journal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:ca73c6b1-fbdf-4f2e-820b-388ac66a4e1aEnglishSymplectic Elements at Oxford2001Lindegårth, NFunding, LBergqvist, YA bioanalytical method for the determination of atovaquone in 100 microl blood-spots by solid-phase extraction and high-performance liquid chromatography has been developed and validated. Atovaquone was extracted from the sampling paper in 0.2 M phosphoric acid and a structurally similar internal standard was added with acetonitrile before being loaded onto a C8 end-capped solid-phase extraction column. Atovaquone and internal standard were analysed by high-performance liquid chromatography on a C18 J'Sphere ODS-M80 (150 x 4.0 mm) column with mobile phase acetonitrile-phosphate buffer, 0.01 M, pH 7.0 (65:35, v/v) and UV detection at 277 nm. The intra-assay precision was 2.7% at 12.00 microM and 13.5% at 1.00 microM. The inter-assay precision was 3.3% at 12.00 microM and 15.6% at 1.00 microM. The lower limit of quantification was 1.00 microM. The limit of detection was 0.50 microM.
spellingShingle Lindegårth, N
Funding, L
Bergqvist, Y
Automated solid-phase extraction method for the determination of atovaquone in capillary blood applied onto sampling paper by rapid high-performance liquid chromatography.
title Automated solid-phase extraction method for the determination of atovaquone in capillary blood applied onto sampling paper by rapid high-performance liquid chromatography.
title_full Automated solid-phase extraction method for the determination of atovaquone in capillary blood applied onto sampling paper by rapid high-performance liquid chromatography.
title_fullStr Automated solid-phase extraction method for the determination of atovaquone in capillary blood applied onto sampling paper by rapid high-performance liquid chromatography.
title_full_unstemmed Automated solid-phase extraction method for the determination of atovaquone in capillary blood applied onto sampling paper by rapid high-performance liquid chromatography.
title_short Automated solid-phase extraction method for the determination of atovaquone in capillary blood applied onto sampling paper by rapid high-performance liquid chromatography.
title_sort automated solid phase extraction method for the determination of atovaquone in capillary blood applied onto sampling paper by rapid high performance liquid chromatography
work_keys_str_mv AT lindegarthn automatedsolidphaseextractionmethodforthedeterminationofatovaquoneincapillarybloodappliedontosamplingpaperbyrapidhighperformanceliquidchromatography
AT fundingl automatedsolidphaseextractionmethodforthedeterminationofatovaquoneincapillarybloodappliedontosamplingpaperbyrapidhighperformanceliquidchromatography
AT bergqvisty automatedsolidphaseextractionmethodforthedeterminationofatovaquoneincapillarybloodappliedontosamplingpaperbyrapidhighperformanceliquidchromatography