Automated solid-phase extraction method for the determination of atovaquone in capillary blood applied onto sampling paper by rapid high-performance liquid chromatography.
A bioanalytical method for the determination of atovaquone in 100 microl blood-spots by solid-phase extraction and high-performance liquid chromatography has been developed and validated. Atovaquone was extracted from the sampling paper in 0.2 M phosphoric acid and a structurally similar internal st...
Main Authors: | , , |
---|---|
Format: | Journal article |
Language: | English |
Published: |
2001
|
_version_ | 1797094817589624832 |
---|---|
author | Lindegårth, N Funding, L Bergqvist, Y |
author_facet | Lindegårth, N Funding, L Bergqvist, Y |
author_sort | Lindegårth, N |
collection | OXFORD |
description | A bioanalytical method for the determination of atovaquone in 100 microl blood-spots by solid-phase extraction and high-performance liquid chromatography has been developed and validated. Atovaquone was extracted from the sampling paper in 0.2 M phosphoric acid and a structurally similar internal standard was added with acetonitrile before being loaded onto a C8 end-capped solid-phase extraction column. Atovaquone and internal standard were analysed by high-performance liquid chromatography on a C18 J'Sphere ODS-M80 (150 x 4.0 mm) column with mobile phase acetonitrile-phosphate buffer, 0.01 M, pH 7.0 (65:35, v/v) and UV detection at 277 nm. The intra-assay precision was 2.7% at 12.00 microM and 13.5% at 1.00 microM. The inter-assay precision was 3.3% at 12.00 microM and 15.6% at 1.00 microM. The lower limit of quantification was 1.00 microM. The limit of detection was 0.50 microM. |
first_indexed | 2024-03-07T04:19:14Z |
format | Journal article |
id | oxford-uuid:ca73c6b1-fbdf-4f2e-820b-388ac66a4e1a |
institution | University of Oxford |
language | English |
last_indexed | 2024-03-07T04:19:14Z |
publishDate | 2001 |
record_format | dspace |
spelling | oxford-uuid:ca73c6b1-fbdf-4f2e-820b-388ac66a4e1a2022-03-27T07:07:30ZAutomated solid-phase extraction method for the determination of atovaquone in capillary blood applied onto sampling paper by rapid high-performance liquid chromatography.Journal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:ca73c6b1-fbdf-4f2e-820b-388ac66a4e1aEnglishSymplectic Elements at Oxford2001Lindegårth, NFunding, LBergqvist, YA bioanalytical method for the determination of atovaquone in 100 microl blood-spots by solid-phase extraction and high-performance liquid chromatography has been developed and validated. Atovaquone was extracted from the sampling paper in 0.2 M phosphoric acid and a structurally similar internal standard was added with acetonitrile before being loaded onto a C8 end-capped solid-phase extraction column. Atovaquone and internal standard were analysed by high-performance liquid chromatography on a C18 J'Sphere ODS-M80 (150 x 4.0 mm) column with mobile phase acetonitrile-phosphate buffer, 0.01 M, pH 7.0 (65:35, v/v) and UV detection at 277 nm. The intra-assay precision was 2.7% at 12.00 microM and 13.5% at 1.00 microM. The inter-assay precision was 3.3% at 12.00 microM and 15.6% at 1.00 microM. The lower limit of quantification was 1.00 microM. The limit of detection was 0.50 microM. |
spellingShingle | Lindegårth, N Funding, L Bergqvist, Y Automated solid-phase extraction method for the determination of atovaquone in capillary blood applied onto sampling paper by rapid high-performance liquid chromatography. |
title | Automated solid-phase extraction method for the determination of atovaquone in capillary blood applied onto sampling paper by rapid high-performance liquid chromatography. |
title_full | Automated solid-phase extraction method for the determination of atovaquone in capillary blood applied onto sampling paper by rapid high-performance liquid chromatography. |
title_fullStr | Automated solid-phase extraction method for the determination of atovaquone in capillary blood applied onto sampling paper by rapid high-performance liquid chromatography. |
title_full_unstemmed | Automated solid-phase extraction method for the determination of atovaquone in capillary blood applied onto sampling paper by rapid high-performance liquid chromatography. |
title_short | Automated solid-phase extraction method for the determination of atovaquone in capillary blood applied onto sampling paper by rapid high-performance liquid chromatography. |
title_sort | automated solid phase extraction method for the determination of atovaquone in capillary blood applied onto sampling paper by rapid high performance liquid chromatography |
work_keys_str_mv | AT lindegarthn automatedsolidphaseextractionmethodforthedeterminationofatovaquoneincapillarybloodappliedontosamplingpaperbyrapidhighperformanceliquidchromatography AT fundingl automatedsolidphaseextractionmethodforthedeterminationofatovaquoneincapillarybloodappliedontosamplingpaperbyrapidhighperformanceliquidchromatography AT bergqvisty automatedsolidphaseextractionmethodforthedeterminationofatovaquoneincapillarybloodappliedontosamplingpaperbyrapidhighperformanceliquidchromatography |