Estimating central blood pressure from a single peripheral pressure measurement

This paper presents a set of criteria used to identify the parameters describing a tube-load model of the arterial system to estimate central blood pressure (BP). The criteria are generalizable to accommodate for inter- and intra-subject variability encountered in the ICU. The proposed single measur...

Полное описание

Библиографические подробности
Главные авторы: Murphy, L, Chase, G, Davidson, S, Desaive, T
Формат: Conference item
Язык:English
Опубликовано: Elsevier 2021
_version_ 1826309017839861760
author Murphy, L
Chase, G
Davidson, S
Desaive, T
author_facet Murphy, L
Chase, G
Davidson, S
Desaive, T
author_sort Murphy, L
collection OXFORD
description This paper presents a set of criteria used to identify the parameters describing a tube-load model of the arterial system to estimate central blood pressure (BP). The criteria are generalizable to accommodate for inter- and intra-subject variability encountered in the ICU. The proposed single measurement transfer function (SMTF) requires only a single peripheral pressure measurement, commonly available in the ICU, for central pressure estimation, removing the need for an additional measurement of pulse transit time, common to other central BP estimation models. The method was tested using data from six (6) porcine experiments where septic shock was induced and subsequent treatment was performed. Systolic pressure (SP), pulse pressure (PP) and root-mean-squared (RMSE) errors relative to invasive measurements of aortic pressure were used to assess accuracy. The SMTF method produced mean errors =5mmHg across all metrics with 84.4, 88.7 and 63.2% of SP, PP, and RMSE, respectively, within this bound of measured central pressure. Peripheral BP accuracy was also assessed as it is commonly used as a surrogate for central BP in clinical settings. Finally, two alternate methods utilizing the same model equations with additional inputs, one using the measured pulse transit time and the other minimizing the RMSE with measured aortic pressure, were implemented to compare the SMTF accuracy to best case outputs given the model equations.
first_indexed 2024-03-07T07:27:57Z
format Conference item
id oxford-uuid:cecfcda8-12f6-4c08-aa5d-129e50a003d4
institution University of Oxford
language English
last_indexed 2024-03-07T07:27:57Z
publishDate 2021
publisher Elsevier
record_format dspace
spelling oxford-uuid:cecfcda8-12f6-4c08-aa5d-129e50a003d42022-11-28T13:53:46ZEstimating central blood pressure from a single peripheral pressure measurementConference itemhttp://purl.org/coar/resource_type/c_5794uuid:cecfcda8-12f6-4c08-aa5d-129e50a003d4EnglishSymplectic ElementsElsevier2021Murphy, LChase, GDavidson, SDesaive, TThis paper presents a set of criteria used to identify the parameters describing a tube-load model of the arterial system to estimate central blood pressure (BP). The criteria are generalizable to accommodate for inter- and intra-subject variability encountered in the ICU. The proposed single measurement transfer function (SMTF) requires only a single peripheral pressure measurement, commonly available in the ICU, for central pressure estimation, removing the need for an additional measurement of pulse transit time, common to other central BP estimation models. The method was tested using data from six (6) porcine experiments where septic shock was induced and subsequent treatment was performed. Systolic pressure (SP), pulse pressure (PP) and root-mean-squared (RMSE) errors relative to invasive measurements of aortic pressure were used to assess accuracy. The SMTF method produced mean errors =5mmHg across all metrics with 84.4, 88.7 and 63.2% of SP, PP, and RMSE, respectively, within this bound of measured central pressure. Peripheral BP accuracy was also assessed as it is commonly used as a surrogate for central BP in clinical settings. Finally, two alternate methods utilizing the same model equations with additional inputs, one using the measured pulse transit time and the other minimizing the RMSE with measured aortic pressure, were implemented to compare the SMTF accuracy to best case outputs given the model equations.
spellingShingle Murphy, L
Chase, G
Davidson, S
Desaive, T
Estimating central blood pressure from a single peripheral pressure measurement
title Estimating central blood pressure from a single peripheral pressure measurement
title_full Estimating central blood pressure from a single peripheral pressure measurement
title_fullStr Estimating central blood pressure from a single peripheral pressure measurement
title_full_unstemmed Estimating central blood pressure from a single peripheral pressure measurement
title_short Estimating central blood pressure from a single peripheral pressure measurement
title_sort estimating central blood pressure from a single peripheral pressure measurement
work_keys_str_mv AT murphyl estimatingcentralbloodpressurefromasingleperipheralpressuremeasurement
AT chaseg estimatingcentralbloodpressurefromasingleperipheralpressuremeasurement
AT davidsons estimatingcentralbloodpressurefromasingleperipheralpressuremeasurement
AT desaivet estimatingcentralbloodpressurefromasingleperipheralpressuremeasurement