Optimization of porous silicon conditions for DNA-based biosensing via reflectometric interference spectroscopy

<p>Objective</p> <p>Substantial effort has been put into designing DNA-based biosensors, which are commonly used to detect presence of known sequences including the quantification of gene expression. Porous silicon (PSi), as a nanostructured base, has been commonly used in the fabr...

Full description

Bibliographic Details
Main Authors: Rahimi, F, Fardindoost, S, Ansari-Pour, N, Sepehri, F, Makiyan, F, Shafiekhani, A, Rezayan, A
Format: Journal article
Language:English
Published: Royan Institute 2019
_version_ 1826297684676313088
author Rahimi, F
Fardindoost, S
Ansari-Pour, N
Sepehri, F
Makiyan, F
Shafiekhani, A
Rezayan, A
author_facet Rahimi, F
Fardindoost, S
Ansari-Pour, N
Sepehri, F
Makiyan, F
Shafiekhani, A
Rezayan, A
author_sort Rahimi, F
collection OXFORD
description <p>Objective</p> <p>Substantial effort has been put into designing DNA-based biosensors, which are commonly used to detect presence of known sequences including the quantification of gene expression. Porous silicon (PSi), as a nanostructured base, has been commonly used in the fabrication of optimally transducing biosensors. Given that the function of any PSi-based biosensor is highly dependent on its nanomorphology, we systematically optimized a PSi biosensor based on reflectometric interference spectroscopy (RIS) detecting the high penetrance breast cancer susceptibility gene, BRCA1.</p> <p>Materials and Methods</p> <p>In this experimental study, PSi pore sizes on the PSi surface were controlled for optimum filling with DNA oligonucleotides and surface roughness was optimized for obtaining higher resolution RIS patterns. In addition, the influence of two different organic electrolyte mixtures on the formation and morphology of the pores, based on various current densities and etching times on doped p-type silicon, were examined. Moreover, we introduce two cleaning processes which can efficiently remove the undesirable outer parasitic layer created during PSi formation. Results of all the optimization steps were observed by field emission scanning electron microscopy (FE-SEM).</p> <p>Results</p> <p>DNA sensing reached its optimum when PSi was formed in a two-step process in the ethanol electrolyte accompanied by removal of the parasitic layer in NaOH solution. These optimal conditions, which result in pore sizes of approximately 20 nm as well as a low surface roughness, provide a considerable RIS shift upon complementary sequence hybridization, suggesting efficient detectability.</p> <p>Conclusion</p> <p>We demonstrate that the optimal conditions identified here makes PSi an attractive solid-phase DNA-based biosensing method and may be used to not only detect full complementary DNA sequences, but it may also be used for detecting point mutations such as single nucleotide substitutions and indels.</p>
first_indexed 2024-03-07T04:35:25Z
format Journal article
id oxford-uuid:cfc045ab-32e5-4e6f-b96a-cacd9d6c89d4
institution University of Oxford
language English
last_indexed 2024-03-07T04:35:25Z
publishDate 2019
publisher Royan Institute
record_format dspace
spelling oxford-uuid:cfc045ab-32e5-4e6f-b96a-cacd9d6c89d42022-03-27T07:44:58ZOptimization of porous silicon conditions for DNA-based biosensing via reflectometric interference spectroscopyJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:cfc045ab-32e5-4e6f-b96a-cacd9d6c89d4EnglishSymplectic Elements at OxfordRoyan Institute2019Rahimi, FFardindoost, SAnsari-Pour, NSepehri, FMakiyan, FShafiekhani, ARezayan, A<p>Objective</p> <p>Substantial effort has been put into designing DNA-based biosensors, which are commonly used to detect presence of known sequences including the quantification of gene expression. Porous silicon (PSi), as a nanostructured base, has been commonly used in the fabrication of optimally transducing biosensors. Given that the function of any PSi-based biosensor is highly dependent on its nanomorphology, we systematically optimized a PSi biosensor based on reflectometric interference spectroscopy (RIS) detecting the high penetrance breast cancer susceptibility gene, BRCA1.</p> <p>Materials and Methods</p> <p>In this experimental study, PSi pore sizes on the PSi surface were controlled for optimum filling with DNA oligonucleotides and surface roughness was optimized for obtaining higher resolution RIS patterns. In addition, the influence of two different organic electrolyte mixtures on the formation and morphology of the pores, based on various current densities and etching times on doped p-type silicon, were examined. Moreover, we introduce two cleaning processes which can efficiently remove the undesirable outer parasitic layer created during PSi formation. Results of all the optimization steps were observed by field emission scanning electron microscopy (FE-SEM).</p> <p>Results</p> <p>DNA sensing reached its optimum when PSi was formed in a two-step process in the ethanol electrolyte accompanied by removal of the parasitic layer in NaOH solution. These optimal conditions, which result in pore sizes of approximately 20 nm as well as a low surface roughness, provide a considerable RIS shift upon complementary sequence hybridization, suggesting efficient detectability.</p> <p>Conclusion</p> <p>We demonstrate that the optimal conditions identified here makes PSi an attractive solid-phase DNA-based biosensing method and may be used to not only detect full complementary DNA sequences, but it may also be used for detecting point mutations such as single nucleotide substitutions and indels.</p>
spellingShingle Rahimi, F
Fardindoost, S
Ansari-Pour, N
Sepehri, F
Makiyan, F
Shafiekhani, A
Rezayan, A
Optimization of porous silicon conditions for DNA-based biosensing via reflectometric interference spectroscopy
title Optimization of porous silicon conditions for DNA-based biosensing via reflectometric interference spectroscopy
title_full Optimization of porous silicon conditions for DNA-based biosensing via reflectometric interference spectroscopy
title_fullStr Optimization of porous silicon conditions for DNA-based biosensing via reflectometric interference spectroscopy
title_full_unstemmed Optimization of porous silicon conditions for DNA-based biosensing via reflectometric interference spectroscopy
title_short Optimization of porous silicon conditions for DNA-based biosensing via reflectometric interference spectroscopy
title_sort optimization of porous silicon conditions for dna based biosensing via reflectometric interference spectroscopy
work_keys_str_mv AT rahimif optimizationofporoussiliconconditionsfordnabasedbiosensingviareflectometricinterferencespectroscopy
AT fardindoosts optimizationofporoussiliconconditionsfordnabasedbiosensingviareflectometricinterferencespectroscopy
AT ansaripourn optimizationofporoussiliconconditionsfordnabasedbiosensingviareflectometricinterferencespectroscopy
AT sepehrif optimizationofporoussiliconconditionsfordnabasedbiosensingviareflectometricinterferencespectroscopy
AT makiyanf optimizationofporoussiliconconditionsfordnabasedbiosensingviareflectometricinterferencespectroscopy
AT shafiekhania optimizationofporoussiliconconditionsfordnabasedbiosensingviareflectometricinterferencespectroscopy
AT rezayana optimizationofporoussiliconconditionsfordnabasedbiosensingviareflectometricinterferencespectroscopy