A low-latency sub-micron resolution stripline beam position monitoring system for single-pass beamlines
A low-latency, sub-micron resolution stripline beam position monitoring system has been developed for use in single-pass beamlines. The fast analogue front-end signal processor is based on a single-stage RF down-mixer and is combined with an FPGA-based system for digitisation and further signal proc...
Autori principali: | , , , , , , , , , |
---|---|
Natura: | Conference item |
Pubblicazione: |
2012
|
_version_ | 1826297954403614720 |
---|---|
author | Burrows, P Bett, DR Blaskovic Kraljevic, N Christian, G Davis, MR Perry, C Apsimon, R Constance, B Gerbershagen, A Resta Ĺopez, J |
author_facet | Burrows, P Bett, DR Blaskovic Kraljevic, N Christian, G Davis, MR Perry, C Apsimon, R Constance, B Gerbershagen, A Resta Ĺopez, J |
author_sort | Burrows, P |
collection | OXFORD |
description | A low-latency, sub-micron resolution stripline beam position monitoring system has been developed for use in single-pass beamlines. The fast analogue front-end signal processor is based on a single-stage RF down-mixer and is combined with an FPGA-based system for digitisation and further signal processing. The system has been deployed and tested with beam at the Accelerator Test Facility at KEK. Performance results are presented on the calibration, resolution and stability of the system. A detailed simulation has been developed that is able to account for the measured performance. Copyright © 2012 by IEEE. |
first_indexed | 2024-03-07T04:39:27Z |
format | Conference item |
id | oxford-uuid:d11dd964-a7be-4aca-b977-d60e2961a271 |
institution | University of Oxford |
last_indexed | 2024-03-07T04:39:27Z |
publishDate | 2012 |
record_format | dspace |
spelling | oxford-uuid:d11dd964-a7be-4aca-b977-d60e2961a2712022-03-27T07:54:45ZA low-latency sub-micron resolution stripline beam position monitoring system for single-pass beamlinesConference itemhttp://purl.org/coar/resource_type/c_5794uuid:d11dd964-a7be-4aca-b977-d60e2961a271Symplectic Elements at Oxford2012Burrows, PBett, DRBlaskovic Kraljevic, NChristian, GDavis, MRPerry, CApsimon, RConstance, BGerbershagen, AResta Ĺopez, JA low-latency, sub-micron resolution stripline beam position monitoring system has been developed for use in single-pass beamlines. The fast analogue front-end signal processor is based on a single-stage RF down-mixer and is combined with an FPGA-based system for digitisation and further signal processing. The system has been deployed and tested with beam at the Accelerator Test Facility at KEK. Performance results are presented on the calibration, resolution and stability of the system. A detailed simulation has been developed that is able to account for the measured performance. Copyright © 2012 by IEEE. |
spellingShingle | Burrows, P Bett, DR Blaskovic Kraljevic, N Christian, G Davis, MR Perry, C Apsimon, R Constance, B Gerbershagen, A Resta Ĺopez, J A low-latency sub-micron resolution stripline beam position monitoring system for single-pass beamlines |
title | A low-latency sub-micron resolution stripline beam position monitoring system for single-pass beamlines |
title_full | A low-latency sub-micron resolution stripline beam position monitoring system for single-pass beamlines |
title_fullStr | A low-latency sub-micron resolution stripline beam position monitoring system for single-pass beamlines |
title_full_unstemmed | A low-latency sub-micron resolution stripline beam position monitoring system for single-pass beamlines |
title_short | A low-latency sub-micron resolution stripline beam position monitoring system for single-pass beamlines |
title_sort | low latency sub micron resolution stripline beam position monitoring system for single pass beamlines |
work_keys_str_mv | AT burrowsp alowlatencysubmicronresolutionstriplinebeampositionmonitoringsystemforsinglepassbeamlines AT bettdr alowlatencysubmicronresolutionstriplinebeampositionmonitoringsystemforsinglepassbeamlines AT blaskovickraljevicn alowlatencysubmicronresolutionstriplinebeampositionmonitoringsystemforsinglepassbeamlines AT christiang alowlatencysubmicronresolutionstriplinebeampositionmonitoringsystemforsinglepassbeamlines AT davismr alowlatencysubmicronresolutionstriplinebeampositionmonitoringsystemforsinglepassbeamlines AT perryc alowlatencysubmicronresolutionstriplinebeampositionmonitoringsystemforsinglepassbeamlines AT apsimonr alowlatencysubmicronresolutionstriplinebeampositionmonitoringsystemforsinglepassbeamlines AT constanceb alowlatencysubmicronresolutionstriplinebeampositionmonitoringsystemforsinglepassbeamlines AT gerbershagena alowlatencysubmicronresolutionstriplinebeampositionmonitoringsystemforsinglepassbeamlines AT restalopezj alowlatencysubmicronresolutionstriplinebeampositionmonitoringsystemforsinglepassbeamlines AT burrowsp lowlatencysubmicronresolutionstriplinebeampositionmonitoringsystemforsinglepassbeamlines AT bettdr lowlatencysubmicronresolutionstriplinebeampositionmonitoringsystemforsinglepassbeamlines AT blaskovickraljevicn lowlatencysubmicronresolutionstriplinebeampositionmonitoringsystemforsinglepassbeamlines AT christiang lowlatencysubmicronresolutionstriplinebeampositionmonitoringsystemforsinglepassbeamlines AT davismr lowlatencysubmicronresolutionstriplinebeampositionmonitoringsystemforsinglepassbeamlines AT perryc lowlatencysubmicronresolutionstriplinebeampositionmonitoringsystemforsinglepassbeamlines AT apsimonr lowlatencysubmicronresolutionstriplinebeampositionmonitoringsystemforsinglepassbeamlines AT constanceb lowlatencysubmicronresolutionstriplinebeampositionmonitoringsystemforsinglepassbeamlines AT gerbershagena lowlatencysubmicronresolutionstriplinebeampositionmonitoringsystemforsinglepassbeamlines AT restalopezj lowlatencysubmicronresolutionstriplinebeampositionmonitoringsystemforsinglepassbeamlines |