The Oxford Dodo. Seeing more than ever before: x-ray micro-CT scanning, specimen acquisition and provenance

The Oxford Dodo (Raphus cucullatus) has been in the collections of the University of Oxford since 1683, first in the Ashmolean Museum and latterly in Oxford University Museum of Natural History. Prior to this the specimen was part of the collections of the Tradescants, father and son, and likely acq...

Mô tả đầy đủ

Chi tiết về thư mục
Những tác giả chính: Warnett, JM, Williams, MA, Wilson, PF, Smith, MP
Định dạng: Journal article
Ngôn ngữ:English
Được phát hành: Taylor and Francis 2020
_version_ 1826297955243524096
author Warnett, JM
Williams, MA
Wilson, PF
Smith, MP
author_facet Warnett, JM
Williams, MA
Wilson, PF
Smith, MP
author_sort Warnett, JM
collection OXFORD
description The Oxford Dodo (Raphus cucullatus) has been in the collections of the University of Oxford since 1683, first in the Ashmolean Museum and latterly in Oxford University Museum of Natural History. Prior to this the specimen was part of the collections of the Tradescants, father and son, and likely acquired between 1634 and 1656, in the Musæum Tradescantianum in what is now Vauxhall, south London. It has been thought probable that this specimen was once the live bird recorded in London by Sir Hamon L’Estrange in around 1638, but X-ray CT scanning of the skull for anatomical investigation has cast doubt on the provenance of the Oxford Dodo. The 3D visualisation revealed 115 metal particles embedded within the bone of the skull, concentrated in the left side of the skull. All but 5 of the particles are less than 1 mm in diameter and their location leads to the conclusion that they represent lead shot consistent with the bird being shot from the rear right of the head, perhaps with a ventral component. This forensic discovery leaves the provenance of the Oxford specimen uncertain but illustrates the value of non-invasive visualisation techniques in determining the potentially complex histories of unique museum objects.
first_indexed 2024-03-07T04:39:28Z
format Journal article
id oxford-uuid:d11e643a-a133-499c-a608-38ed9a5f4f50
institution University of Oxford
language English
last_indexed 2024-03-07T04:39:28Z
publishDate 2020
publisher Taylor and Francis
record_format dspace
spelling oxford-uuid:d11e643a-a133-499c-a608-38ed9a5f4f502022-03-27T07:54:50ZThe Oxford Dodo. Seeing more than ever before: x-ray micro-CT scanning, specimen acquisition and provenanceJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:d11e643a-a133-499c-a608-38ed9a5f4f50EnglishSymplectic ElementsTaylor and Francis2020Warnett, JMWilliams, MAWilson, PFSmith, MPThe Oxford Dodo (Raphus cucullatus) has been in the collections of the University of Oxford since 1683, first in the Ashmolean Museum and latterly in Oxford University Museum of Natural History. Prior to this the specimen was part of the collections of the Tradescants, father and son, and likely acquired between 1634 and 1656, in the Musæum Tradescantianum in what is now Vauxhall, south London. It has been thought probable that this specimen was once the live bird recorded in London by Sir Hamon L’Estrange in around 1638, but X-ray CT scanning of the skull for anatomical investigation has cast doubt on the provenance of the Oxford Dodo. The 3D visualisation revealed 115 metal particles embedded within the bone of the skull, concentrated in the left side of the skull. All but 5 of the particles are less than 1 mm in diameter and their location leads to the conclusion that they represent lead shot consistent with the bird being shot from the rear right of the head, perhaps with a ventral component. This forensic discovery leaves the provenance of the Oxford specimen uncertain but illustrates the value of non-invasive visualisation techniques in determining the potentially complex histories of unique museum objects.
spellingShingle Warnett, JM
Williams, MA
Wilson, PF
Smith, MP
The Oxford Dodo. Seeing more than ever before: x-ray micro-CT scanning, specimen acquisition and provenance
title The Oxford Dodo. Seeing more than ever before: x-ray micro-CT scanning, specimen acquisition and provenance
title_full The Oxford Dodo. Seeing more than ever before: x-ray micro-CT scanning, specimen acquisition and provenance
title_fullStr The Oxford Dodo. Seeing more than ever before: x-ray micro-CT scanning, specimen acquisition and provenance
title_full_unstemmed The Oxford Dodo. Seeing more than ever before: x-ray micro-CT scanning, specimen acquisition and provenance
title_short The Oxford Dodo. Seeing more than ever before: x-ray micro-CT scanning, specimen acquisition and provenance
title_sort oxford dodo seeing more than ever before x ray micro ct scanning specimen acquisition and provenance
work_keys_str_mv AT warnettjm theoxforddodoseeingmorethaneverbeforexraymicroctscanningspecimenacquisitionandprovenance
AT williamsma theoxforddodoseeingmorethaneverbeforexraymicroctscanningspecimenacquisitionandprovenance
AT wilsonpf theoxforddodoseeingmorethaneverbeforexraymicroctscanningspecimenacquisitionandprovenance
AT smithmp theoxforddodoseeingmorethaneverbeforexraymicroctscanningspecimenacquisitionandprovenance
AT warnettjm oxforddodoseeingmorethaneverbeforexraymicroctscanningspecimenacquisitionandprovenance
AT williamsma oxforddodoseeingmorethaneverbeforexraymicroctscanningspecimenacquisitionandprovenance
AT wilsonpf oxforddodoseeingmorethaneverbeforexraymicroctscanningspecimenacquisitionandprovenance
AT smithmp oxforddodoseeingmorethaneverbeforexraymicroctscanningspecimenacquisitionandprovenance