Porosity characterization of fiber-reinforced ceramic matrix composite using synchrotron X-ray computed tomography
The pore structure and porosity of a continuous fiber reinforced ceramic matrix composite has been characterized using high-resolution synchrotron X-ray computed tomography (XCT). Segmentation of the reconstructed tomograph images reveals different types of pores within the composite, the inter-fibe...
Príomhchruthaitheoirí: | Zou, C, Marrow, T, Reinhard, C, Li, B, Zhang, C, Wang, S |
---|---|
Formáid: | Journal article |
Foilsithe / Cruthaithe: |
Institute of Physics
2016
|
Míreanna comhchosúla
Míreanna comhchosúla
-
X-ray Computed Tomography Inspection of Novel Ceramic Matrix Composites
de réir: Nick Brierley, et al.
Foilsithe / Cruthaithe: (2023-08-01) -
Microstructure Characterization by X-Ray Computed Tomography of C/C-SiC Ceramic Composites Fabricated with Different Carbon Fiber Architectures
de réir: Wan, F, et al.
Foilsithe / Cruthaithe: (2019) -
Synchrotron X-ray characterisation of crack strain fields in polygranular graphite
de réir: Barhli, S, et al.
Foilsithe / Cruthaithe: (2017) -
Three-dimensional displacement mapping of diffused Pt thermal barrier coatings via synchrotron X-ray computed tomography and digital volume correlation
de réir: Khoshkhou, D, et al.
Foilsithe / Cruthaithe: (2016) -
Synchrotron X-ray Microprobes: An Application on Ancient Ceramics
de réir: Alessandra Gianoncelli, et al.
Foilsithe / Cruthaithe: (2021-08-01)