Changes in pulse transit time and pulse rate as markers of arousal from sleep in normal subjects.

1. Obstructive sleep apnoea and its variants often provoke hundreds of short arousals that lead to the most important symptom, disabling hypersomnolence. The measurement of sleep in these conditions requires the documentation of these short arousals and this is conventionally done by manual inspecti...

Full description

Bibliographic Details
Main Authors: Pitson, D, Chhina, N, Knijn, S, van Herwaaden, M, Stradling, J
Format: Journal article
Language:English
Published: 1994
_version_ 1797097481790554112
author Pitson, D
Chhina, N
Knijn, S
van Herwaaden, M
Stradling, J
author_facet Pitson, D
Chhina, N
Knijn, S
van Herwaaden, M
Stradling, J
author_sort Pitson, D
collection OXFORD
description 1. Obstructive sleep apnoea and its variants often provoke hundreds of short arousals that lead to the most important symptom, disabling hypersomnolence. The measurement of sleep in these conditions requires the documentation of these short arousals and this is conventionally done by manual inspection of the sleeping EEG, a laborious procedure. 2. Other markers of 'arousal', that are easier to measure and document, include several cardiovascular signals that change as part of the orienting reflex: pulse rate rise, blood pressure rise, skin vasoconstriction, for example. 3. Pulse transit time (measured as the interval from the ECG R-wave until the arrival of the pulse pressure wave at the periphery, about 250 ms) varies inversely with blood pressure and provides a beat-to-beat estimation of blood pressure changes. 4. In eight normal subjects we have assessed the relationship between transient EEG arousals of different length (provoked by external stimuli) and changes in both pulse transit time and heart rate. 5. Significant falls in pulse transit time occurred in response to external stimuli [15.1 (SEM 1.4) ms], indicating a rise in blood pressure, and were significant even when there was no discernible change in the EEG [9.9 (SEM 2.6) ms]. Significant changes in heart rate also occurred [10.3 (SEM 1.2) beats/min], but were slightly less sensitive than changes in pulse transit time. 6. Changes in pulse transit time (and to a lesser extent pulse rate) are sensitive markers of EEG arousal. As such they should be useful to include when monitoring sleep and its disorders, particularly since pulse transit time recorders can easily be made portable for home use.
first_indexed 2024-03-07T04:56:09Z
format Journal article
id oxford-uuid:d6aaeddb-f323-4187-a07c-d6e617e8bd04
institution University of Oxford
language English
last_indexed 2024-03-07T04:56:09Z
publishDate 1994
record_format dspace
spelling oxford-uuid:d6aaeddb-f323-4187-a07c-d6e617e8bd042022-03-27T08:35:09ZChanges in pulse transit time and pulse rate as markers of arousal from sleep in normal subjects.Journal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:d6aaeddb-f323-4187-a07c-d6e617e8bd04EnglishSymplectic Elements at Oxford1994Pitson, DChhina, NKnijn, Svan Herwaaden, MStradling, J1. Obstructive sleep apnoea and its variants often provoke hundreds of short arousals that lead to the most important symptom, disabling hypersomnolence. The measurement of sleep in these conditions requires the documentation of these short arousals and this is conventionally done by manual inspection of the sleeping EEG, a laborious procedure. 2. Other markers of 'arousal', that are easier to measure and document, include several cardiovascular signals that change as part of the orienting reflex: pulse rate rise, blood pressure rise, skin vasoconstriction, for example. 3. Pulse transit time (measured as the interval from the ECG R-wave until the arrival of the pulse pressure wave at the periphery, about 250 ms) varies inversely with blood pressure and provides a beat-to-beat estimation of blood pressure changes. 4. In eight normal subjects we have assessed the relationship between transient EEG arousals of different length (provoked by external stimuli) and changes in both pulse transit time and heart rate. 5. Significant falls in pulse transit time occurred in response to external stimuli [15.1 (SEM 1.4) ms], indicating a rise in blood pressure, and were significant even when there was no discernible change in the EEG [9.9 (SEM 2.6) ms]. Significant changes in heart rate also occurred [10.3 (SEM 1.2) beats/min], but were slightly less sensitive than changes in pulse transit time. 6. Changes in pulse transit time (and to a lesser extent pulse rate) are sensitive markers of EEG arousal. As such they should be useful to include when monitoring sleep and its disorders, particularly since pulse transit time recorders can easily be made portable for home use.
spellingShingle Pitson, D
Chhina, N
Knijn, S
van Herwaaden, M
Stradling, J
Changes in pulse transit time and pulse rate as markers of arousal from sleep in normal subjects.
title Changes in pulse transit time and pulse rate as markers of arousal from sleep in normal subjects.
title_full Changes in pulse transit time and pulse rate as markers of arousal from sleep in normal subjects.
title_fullStr Changes in pulse transit time and pulse rate as markers of arousal from sleep in normal subjects.
title_full_unstemmed Changes in pulse transit time and pulse rate as markers of arousal from sleep in normal subjects.
title_short Changes in pulse transit time and pulse rate as markers of arousal from sleep in normal subjects.
title_sort changes in pulse transit time and pulse rate as markers of arousal from sleep in normal subjects
work_keys_str_mv AT pitsond changesinpulsetransittimeandpulserateasmarkersofarousalfromsleepinnormalsubjects
AT chhinan changesinpulsetransittimeandpulserateasmarkersofarousalfromsleepinnormalsubjects
AT knijns changesinpulsetransittimeandpulserateasmarkersofarousalfromsleepinnormalsubjects
AT vanherwaadenm changesinpulsetransittimeandpulserateasmarkersofarousalfromsleepinnormalsubjects
AT stradlingj changesinpulsetransittimeandpulserateasmarkersofarousalfromsleepinnormalsubjects