A method for the automated detection of venous gas bubbles in humans using empirical mode decomposition.

Doppler ultrasound signals are widely used to grade the quantity of circulating venous bubbles in divers. Current techniques rely on trained observers, making the grading process both time-consuming and subjective. The automated detection of bubbles, however, is confounded by the presence of other s...

Ful tanımlama

Detaylı Bibliyografya
Asıl Yazarlar: Chappell, M, Payne, S
Materyal Türü: Journal article
Dil:English
Baskı/Yayın Bilgisi: 2005
_version_ 1826299278408024064
author Chappell, M
Payne, S
author_facet Chappell, M
Payne, S
author_sort Chappell, M
collection OXFORD
description Doppler ultrasound signals are widely used to grade the quantity of circulating venous bubbles in divers. Current techniques rely on trained observers, making the grading process both time-consuming and subjective. The automated detection of bubbles, however, is confounded by the presence of other signals, primarily those arising from blood motion. Empirical Mode Decomposition was used here to calculate the intrinsic mode functions (IMFs) of a number of Doppler ultrasound signals from recreational divers, post-decompression. The IMFs provide a basis set for signal decomposition, each IMF corresponding to a different timescale in the signal. Each signal was found to comprise approximately 20 IMFs: the precise number being dependent upon the nature of the signal. A method is presented to detect bubbles using the IMF; features are first identified in the individual heart cycles, these having been previously determined using a robust peak detection method, by examining deviations from the ensemble averaged IMF. Bubbles are then identified as features appearing in more than one IMF, with significant energy in the original signal. This method has been applied to a subset of the available database and appears to perform with good sensitivity even when the signal has variable signal strength.
first_indexed 2024-03-07T04:59:29Z
format Journal article
id oxford-uuid:d7c981fe-4f02-4e91-aee7-57b06c92128e
institution University of Oxford
language English
last_indexed 2024-03-07T04:59:29Z
publishDate 2005
record_format dspace
spelling oxford-uuid:d7c981fe-4f02-4e91-aee7-57b06c92128e2022-03-27T08:43:32ZA method for the automated detection of venous gas bubbles in humans using empirical mode decomposition.Journal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:d7c981fe-4f02-4e91-aee7-57b06c92128eEnglishSymplectic Elements at Oxford2005Chappell, MPayne, SDoppler ultrasound signals are widely used to grade the quantity of circulating venous bubbles in divers. Current techniques rely on trained observers, making the grading process both time-consuming and subjective. The automated detection of bubbles, however, is confounded by the presence of other signals, primarily those arising from blood motion. Empirical Mode Decomposition was used here to calculate the intrinsic mode functions (IMFs) of a number of Doppler ultrasound signals from recreational divers, post-decompression. The IMFs provide a basis set for signal decomposition, each IMF corresponding to a different timescale in the signal. Each signal was found to comprise approximately 20 IMFs: the precise number being dependent upon the nature of the signal. A method is presented to detect bubbles using the IMF; features are first identified in the individual heart cycles, these having been previously determined using a robust peak detection method, by examining deviations from the ensemble averaged IMF. Bubbles are then identified as features appearing in more than one IMF, with significant energy in the original signal. This method has been applied to a subset of the available database and appears to perform with good sensitivity even when the signal has variable signal strength.
spellingShingle Chappell, M
Payne, S
A method for the automated detection of venous gas bubbles in humans using empirical mode decomposition.
title A method for the automated detection of venous gas bubbles in humans using empirical mode decomposition.
title_full A method for the automated detection of venous gas bubbles in humans using empirical mode decomposition.
title_fullStr A method for the automated detection of venous gas bubbles in humans using empirical mode decomposition.
title_full_unstemmed A method for the automated detection of venous gas bubbles in humans using empirical mode decomposition.
title_short A method for the automated detection of venous gas bubbles in humans using empirical mode decomposition.
title_sort method for the automated detection of venous gas bubbles in humans using empirical mode decomposition
work_keys_str_mv AT chappellm amethodfortheautomateddetectionofvenousgasbubblesinhumansusingempiricalmodedecomposition
AT paynes amethodfortheautomateddetectionofvenousgasbubblesinhumansusingempiricalmodedecomposition
AT chappellm methodfortheautomateddetectionofvenousgasbubblesinhumansusingempiricalmodedecomposition
AT paynes methodfortheautomateddetectionofvenousgasbubblesinhumansusingempiricalmodedecomposition