Development of a microfluidic tool for understanding whole cell algal cultures

<p>This project focuses on the development, characterisation and use of a microfluidic tool to study cells in suspension, and the motility of cells. This microfluidic tool is designed to have a low convective flow, so transport is dominated by diffusion, which allows a 2D concentration gradie...

全面介紹

書目詳細資料
主要作者: Glover, K
其他作者: Lubansky, A
格式: Thesis
出版: 2014
_version_ 1826300637404463104
author Glover, K
author2 Lubansky, A
author_facet Lubansky, A
Glover, K
author_sort Glover, K
collection OXFORD
description <p>This project focuses on the development, characterisation and use of a microfluidic tool to study cells in suspension, and the motility of cells. This microfluidic tool is designed to have a low convective flow, so transport is dominated by diffusion, which allows a 2D concentration gradient to be maintained and manipulated, and cells to swim without advection.</p> <p>The rheology of the whole cell cultures was measured and found to shear thinning. Bubbles rising through the fluid was modelled. Despite this, it was found that bubbles rising through whole cell culture would impose a shear that correlated to the viscosity at the high shear plateau. That is bubble size did not significantly affect the apparent viscosity. The medium around bubbles of any size, from 1 mm to 100 mm, has a viscosity of 0.001 Pas.</p> <p>Numerical simulations are used to characterise and optimise the design and operation of the microfluidic devices. Low advection within the central chamber, with desired concentration gradients, was attainable with provided the geometry and operation were within certain limits. Recommendations regarding the geometry of the device include an inlet width to inlet neck length ratio of less than 2 and a radius of less then 400 um. The inlet velocity controlled the maximum velocity within the chamber.</p> <p>PDMS devices were fabricated and operated and it was found that concentration gradients could be maintained, but there were limitation regarding the syringe pump.</p> <p>Proof of concept is presented for visualising cells within this microfluidic device. </p> <p>From this thesis, it has been shown that microfluidic devices have important potential for understanding the motility of microalgae in real environments and in controlled concentration gradients, although they require careful analysis and thoughtful fabrication.</p>
first_indexed 2024-03-07T05:20:12Z
format Thesis
id oxford-uuid:de9eb8ef-a6fa-4dab-aebb-65dc9dc3b4eb
institution University of Oxford
last_indexed 2024-03-07T05:20:12Z
publishDate 2014
record_format dspace
spelling oxford-uuid:de9eb8ef-a6fa-4dab-aebb-65dc9dc3b4eb2022-03-27T09:33:32ZDevelopment of a microfluidic tool for understanding whole cell algal culturesThesishttp://purl.org/coar/resource_type/c_db06uuid:de9eb8ef-a6fa-4dab-aebb-65dc9dc3b4ebORA Deposit2014Glover, KLubansky, AYe, H<p>This project focuses on the development, characterisation and use of a microfluidic tool to study cells in suspension, and the motility of cells. This microfluidic tool is designed to have a low convective flow, so transport is dominated by diffusion, which allows a 2D concentration gradient to be maintained and manipulated, and cells to swim without advection.</p> <p>The rheology of the whole cell cultures was measured and found to shear thinning. Bubbles rising through the fluid was modelled. Despite this, it was found that bubbles rising through whole cell culture would impose a shear that correlated to the viscosity at the high shear plateau. That is bubble size did not significantly affect the apparent viscosity. The medium around bubbles of any size, from 1 mm to 100 mm, has a viscosity of 0.001 Pas.</p> <p>Numerical simulations are used to characterise and optimise the design and operation of the microfluidic devices. Low advection within the central chamber, with desired concentration gradients, was attainable with provided the geometry and operation were within certain limits. Recommendations regarding the geometry of the device include an inlet width to inlet neck length ratio of less than 2 and a radius of less then 400 um. The inlet velocity controlled the maximum velocity within the chamber.</p> <p>PDMS devices were fabricated and operated and it was found that concentration gradients could be maintained, but there were limitation regarding the syringe pump.</p> <p>Proof of concept is presented for visualising cells within this microfluidic device. </p> <p>From this thesis, it has been shown that microfluidic devices have important potential for understanding the motility of microalgae in real environments and in controlled concentration gradients, although they require careful analysis and thoughtful fabrication.</p>
spellingShingle Glover, K
Development of a microfluidic tool for understanding whole cell algal cultures
title Development of a microfluidic tool for understanding whole cell algal cultures
title_full Development of a microfluidic tool for understanding whole cell algal cultures
title_fullStr Development of a microfluidic tool for understanding whole cell algal cultures
title_full_unstemmed Development of a microfluidic tool for understanding whole cell algal cultures
title_short Development of a microfluidic tool for understanding whole cell algal cultures
title_sort development of a microfluidic tool for understanding whole cell algal cultures
work_keys_str_mv AT gloverk developmentofamicrofluidictoolforunderstandingwholecellalgalcultures