Is (re)titration of nasal continuous positive airway pressure for obstructive sleep apnoea necessary?

OBJECTIVE: To assess changes in nasal continuous positive airway pressure (nCPAP) pressure requirements across time in obstructive sleep apnoea (OSA), and whether routine retitrations are indicated. BACKGROUND: Most sleep laboratories perform one nCPAP titration, although some authors have found cha...

Full description

Bibliographic Details
Main Authors: Choi, S, Mullins, R, Crosby, J, Davies, R, Stradling, JR
Format: Journal article
Language:English
Published: 2001
_version_ 1826301293667287040
author Choi, S
Mullins, R
Crosby, J
Davies, R
Stradling, JR
author_facet Choi, S
Mullins, R
Crosby, J
Davies, R
Stradling, JR
author_sort Choi, S
collection OXFORD
description OBJECTIVE: To assess changes in nasal continuous positive airway pressure (nCPAP) pressure requirements across time in obstructive sleep apnoea (OSA), and whether routine retitrations are indicated. BACKGROUND: Most sleep laboratories perform one nCPAP titration, although some authors have found changes in pressures with time. A cohort of patients with OSA in a randomised controlled trial of nCPAP provided us with data on changes in titration pressures with time. METHODS: One hundred and one patients with symptomatic OSA (Epworth Sleepiness Scale > or =10, and >10 episodes/h of >4% dips in SaO(2) overnight) were recruited to a 1 month trial comparing real (autotitrated) and placebo nCPAP. At 1 month all patients were titrated and received real nCPAP thereafter. Eighty five were retitrated at about 6 months. RESULTS: Average pressures did not change between the initial value and 1 month (95th centile, 8.47 (SD 3.00), 8.94 (2.85) cm H(2)O), although there were large individual changes (mean difference, +0.47, SD 2.30, range -5 to +6 cm H(2)O). There was a small fall at 6 months (mean difference -0.68, SD 2.60, range -6 to +6 cm H(2)O, P<0.03) with no suggestion that the changes from 1-6 months were clinically important. CONCLUSIONS: This study suggests that routine nCPAP retitrations are not necessary. In conjunction with other published data, the night to night variation we found implies that a nCPAP calibration using an algorithm (based on obesity and OSA severity) might be as clinically successful as conventional one night titrations. However, further studies will be needed to specifically confirm this hypothesis.
first_indexed 2024-03-07T05:30:12Z
format Journal article
id oxford-uuid:e1fe6b00-5788-4c54-b98a-39bc3fdec8ac
institution University of Oxford
language English
last_indexed 2024-03-07T05:30:12Z
publishDate 2001
record_format dspace
spelling oxford-uuid:e1fe6b00-5788-4c54-b98a-39bc3fdec8ac2022-03-27T09:58:05ZIs (re)titration of nasal continuous positive airway pressure for obstructive sleep apnoea necessary?Journal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:e1fe6b00-5788-4c54-b98a-39bc3fdec8acEnglishSymplectic Elements at Oxford2001Choi, SMullins, RCrosby, JDavies, RStradling, JROBJECTIVE: To assess changes in nasal continuous positive airway pressure (nCPAP) pressure requirements across time in obstructive sleep apnoea (OSA), and whether routine retitrations are indicated. BACKGROUND: Most sleep laboratories perform one nCPAP titration, although some authors have found changes in pressures with time. A cohort of patients with OSA in a randomised controlled trial of nCPAP provided us with data on changes in titration pressures with time. METHODS: One hundred and one patients with symptomatic OSA (Epworth Sleepiness Scale > or =10, and >10 episodes/h of >4% dips in SaO(2) overnight) were recruited to a 1 month trial comparing real (autotitrated) and placebo nCPAP. At 1 month all patients were titrated and received real nCPAP thereafter. Eighty five were retitrated at about 6 months. RESULTS: Average pressures did not change between the initial value and 1 month (95th centile, 8.47 (SD 3.00), 8.94 (2.85) cm H(2)O), although there were large individual changes (mean difference, +0.47, SD 2.30, range -5 to +6 cm H(2)O). There was a small fall at 6 months (mean difference -0.68, SD 2.60, range -6 to +6 cm H(2)O, P<0.03) with no suggestion that the changes from 1-6 months were clinically important. CONCLUSIONS: This study suggests that routine nCPAP retitrations are not necessary. In conjunction with other published data, the night to night variation we found implies that a nCPAP calibration using an algorithm (based on obesity and OSA severity) might be as clinically successful as conventional one night titrations. However, further studies will be needed to specifically confirm this hypothesis.
spellingShingle Choi, S
Mullins, R
Crosby, J
Davies, R
Stradling, JR
Is (re)titration of nasal continuous positive airway pressure for obstructive sleep apnoea necessary?
title Is (re)titration of nasal continuous positive airway pressure for obstructive sleep apnoea necessary?
title_full Is (re)titration of nasal continuous positive airway pressure for obstructive sleep apnoea necessary?
title_fullStr Is (re)titration of nasal continuous positive airway pressure for obstructive sleep apnoea necessary?
title_full_unstemmed Is (re)titration of nasal continuous positive airway pressure for obstructive sleep apnoea necessary?
title_short Is (re)titration of nasal continuous positive airway pressure for obstructive sleep apnoea necessary?
title_sort is re titration of nasal continuous positive airway pressure for obstructive sleep apnoea necessary
work_keys_str_mv AT chois isretitrationofnasalcontinuouspositiveairwaypressureforobstructivesleepapnoeanecessary
AT mullinsr isretitrationofnasalcontinuouspositiveairwaypressureforobstructivesleepapnoeanecessary
AT crosbyj isretitrationofnasalcontinuouspositiveairwaypressureforobstructivesleepapnoeanecessary
AT daviesr isretitrationofnasalcontinuouspositiveairwaypressureforobstructivesleepapnoeanecessary
AT stradlingjr isretitrationofnasalcontinuouspositiveairwaypressureforobstructivesleepapnoeanecessary