Calibration of ultrasound backscatter temperature imaging for high-intensity focused ultrasound treatment planning.

High-intensity focused ultrasound (HIFU) is rapidly gaining acceptance as a non-invasive method for soft tissue tumor ablation, but improvements in the methods of treatment delivery, planning and monitoring are still required. Backscatter temperature imaging (BTI) uses ultrasound to visualize heatin...

Full description

Bibliographic Details
Main Authors: Civale, J, Rivens, I, Ter Haar, G, Morris, H, Coussios, C, Friend, P, Bamber, J
Format: Journal article
Language:English
Published: 2013
_version_ 1797101311649382400
author Civale, J
Rivens, I
Ter Haar, G
Morris, H
Coussios, C
Friend, P
Bamber, J
author_facet Civale, J
Rivens, I
Ter Haar, G
Morris, H
Coussios, C
Friend, P
Bamber, J
author_sort Civale, J
collection OXFORD
description High-intensity focused ultrasound (HIFU) is rapidly gaining acceptance as a non-invasive method for soft tissue tumor ablation, but improvements in the methods of treatment delivery, planning and monitoring are still required. Backscatter temperature imaging (BTI) uses ultrasound to visualize heating-induced echo strain and may be used to indicate the position of the HIFU focal region using low-power "sub-lesioning" exposure. The technique may also provide a quantitative tool for assessing the efficacy of treatment delivery if apparent strain measurements can be related to the underlying temperature rise. To obtain temperature estimates from strain measurements, the relationship between these variables has to be either measured or otherwise assumed from previous calibrations in similar tissues. This article describes experimental measurements aimed at deriving the relationship between temperature rise and apparent strain in the laboratory environment using both ex vivo bovine liver tissue samples and normothermically perfused porcine livers. A BTI algorithm was applied to radiofrequency ultrasound echo data acquired from a clinical ultrasound scanner (Z.One, Zonare Medical Systems, Mountain View, CA, USA) where the imaging probe was aligned with the focal region of a HIFU transducer. Temperature measurements were obtained using needle thermocouples implanted in the liver tissue. A series of "non-ablative" HIFU exposures giving peak temperatures below 10°C were made in three separate ex vivo bovine livers, yielding an average strain/temperature coefficient of 0.126 ± 0.088 percentage strain per degree Celsius. In the perfused porcine livers at a starting temperature of 38°C (normal body temperature) the strain/temperature coefficients were found to be 0.040 ± 0.029 percentage strain per degree Celsius. The uncertainty in these results is directly linked to the precision of the strain measurement, as well as the naturally occurring variance between different tissue samples, indicating that BTI may lack the accuracy required to be implemented successfully in practice as a quantitative treatment planning technique at a sub-lesioning exposure level. This is because, to be of use in treatment planning, temperature-rise estimates may require an accuracy greater (<10%) than that offered by BTI measurement. BTI may, however, still play a role in ensuring the correct positioning of the focal region and as a treatment monitoring modality capable of detecting an increased rate of heating in tissue after HIFU ablation.
first_indexed 2024-03-07T05:50:04Z
format Journal article
id oxford-uuid:e88b1dd9-721d-4445-9b2e-d8681b339b88
institution University of Oxford
language English
last_indexed 2024-03-07T05:50:04Z
publishDate 2013
record_format dspace
spelling oxford-uuid:e88b1dd9-721d-4445-9b2e-d8681b339b882022-03-27T10:47:45ZCalibration of ultrasound backscatter temperature imaging for high-intensity focused ultrasound treatment planning.Journal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:e88b1dd9-721d-4445-9b2e-d8681b339b88EnglishSymplectic Elements at Oxford2013Civale, JRivens, ITer Haar, GMorris, HCoussios, CFriend, PBamber, JHigh-intensity focused ultrasound (HIFU) is rapidly gaining acceptance as a non-invasive method for soft tissue tumor ablation, but improvements in the methods of treatment delivery, planning and monitoring are still required. Backscatter temperature imaging (BTI) uses ultrasound to visualize heating-induced echo strain and may be used to indicate the position of the HIFU focal region using low-power "sub-lesioning" exposure. The technique may also provide a quantitative tool for assessing the efficacy of treatment delivery if apparent strain measurements can be related to the underlying temperature rise. To obtain temperature estimates from strain measurements, the relationship between these variables has to be either measured or otherwise assumed from previous calibrations in similar tissues. This article describes experimental measurements aimed at deriving the relationship between temperature rise and apparent strain in the laboratory environment using both ex vivo bovine liver tissue samples and normothermically perfused porcine livers. A BTI algorithm was applied to radiofrequency ultrasound echo data acquired from a clinical ultrasound scanner (Z.One, Zonare Medical Systems, Mountain View, CA, USA) where the imaging probe was aligned with the focal region of a HIFU transducer. Temperature measurements were obtained using needle thermocouples implanted in the liver tissue. A series of "non-ablative" HIFU exposures giving peak temperatures below 10°C were made in three separate ex vivo bovine livers, yielding an average strain/temperature coefficient of 0.126 ± 0.088 percentage strain per degree Celsius. In the perfused porcine livers at a starting temperature of 38°C (normal body temperature) the strain/temperature coefficients were found to be 0.040 ± 0.029 percentage strain per degree Celsius. The uncertainty in these results is directly linked to the precision of the strain measurement, as well as the naturally occurring variance between different tissue samples, indicating that BTI may lack the accuracy required to be implemented successfully in practice as a quantitative treatment planning technique at a sub-lesioning exposure level. This is because, to be of use in treatment planning, temperature-rise estimates may require an accuracy greater (<10%) than that offered by BTI measurement. BTI may, however, still play a role in ensuring the correct positioning of the focal region and as a treatment monitoring modality capable of detecting an increased rate of heating in tissue after HIFU ablation.
spellingShingle Civale, J
Rivens, I
Ter Haar, G
Morris, H
Coussios, C
Friend, P
Bamber, J
Calibration of ultrasound backscatter temperature imaging for high-intensity focused ultrasound treatment planning.
title Calibration of ultrasound backscatter temperature imaging for high-intensity focused ultrasound treatment planning.
title_full Calibration of ultrasound backscatter temperature imaging for high-intensity focused ultrasound treatment planning.
title_fullStr Calibration of ultrasound backscatter temperature imaging for high-intensity focused ultrasound treatment planning.
title_full_unstemmed Calibration of ultrasound backscatter temperature imaging for high-intensity focused ultrasound treatment planning.
title_short Calibration of ultrasound backscatter temperature imaging for high-intensity focused ultrasound treatment planning.
title_sort calibration of ultrasound backscatter temperature imaging for high intensity focused ultrasound treatment planning
work_keys_str_mv AT civalej calibrationofultrasoundbackscattertemperatureimagingforhighintensityfocusedultrasoundtreatmentplanning
AT rivensi calibrationofultrasoundbackscattertemperatureimagingforhighintensityfocusedultrasoundtreatmentplanning
AT terhaarg calibrationofultrasoundbackscattertemperatureimagingforhighintensityfocusedultrasoundtreatmentplanning
AT morrish calibrationofultrasoundbackscattertemperatureimagingforhighintensityfocusedultrasoundtreatmentplanning
AT coussiosc calibrationofultrasoundbackscattertemperatureimagingforhighintensityfocusedultrasoundtreatmentplanning
AT friendp calibrationofultrasoundbackscattertemperatureimagingforhighintensityfocusedultrasoundtreatmentplanning
AT bamberj calibrationofultrasoundbackscattertemperatureimagingforhighintensityfocusedultrasoundtreatmentplanning