Clinical evaluation of AI-assisted muscle ultrasound for monitoring muscle wasting in ICU patients

Muscle ultrasound has been shown to be a valid and safe imaging modality to assess muscle wasting in critically ill patients in the intensive care unit (ICU). This typically involves manual delineation to measure the rectus femoris cross-sectional area (RFCSA), which is a subjective, time-consuming,...

Fuld beskrivelse

Bibliografiske detaljer
Main Authors: Nhat, PTH, Van Hao, N, Yen, LM, Anh, NH, Khiem, DP, Kerdegari, H, Phuong, LT, Hoang, VT, Ngoc, NT, Thu, LNM, Trung, TN, Pisani, L, Razavi, R, Yacoub, S, Van Vinh Chau, N, King, AP, Thwaites, L, Denehy, L, Gomez, A
Format: Journal article
Sprog:English
Udgivet: Nature Research 2024
_version_ 1826313433157468160
author Nhat, PTH
Van Hao, N
Yen, LM
Anh, NH
Khiem, DP
Kerdegari, H
Phuong, LT
Hoang, VT
Ngoc, NT
Thu, LNM
Trung, TN
Pisani, L
Razavi, R
Yacoub, S
Van Vinh Chau, N
King, AP
Thwaites, L
Denehy, L
Gomez, A
author_facet Nhat, PTH
Van Hao, N
Yen, LM
Anh, NH
Khiem, DP
Kerdegari, H
Phuong, LT
Hoang, VT
Ngoc, NT
Thu, LNM
Trung, TN
Pisani, L
Razavi, R
Yacoub, S
Van Vinh Chau, N
King, AP
Thwaites, L
Denehy, L
Gomez, A
author_sort Nhat, PTH
collection OXFORD
description Muscle ultrasound has been shown to be a valid and safe imaging modality to assess muscle wasting in critically ill patients in the intensive care unit (ICU). This typically involves manual delineation to measure the rectus femoris cross-sectional area (RFCSA), which is a subjective, time-consuming, and laborious task that requires significant expertise. We aimed to develop and evaluate an AI tool that performs automated recognition and measurement of RFCSA to support non-expert operators in measurement of the RFCSA using muscle ultrasound. Twenty patients were recruited between Feb 2023 and July 2023 and were randomized sequentially to operators using AI (n = 10) or non-AI (n = 10). Muscle loss during ICU stay was similar for both methods: 26 ± 15% for AI and 23 ± 11% for the non-AI, respectively (p = 0.13). In total 59 ultrasound examinations were carried out (30 without AI and 29 with AI). When assisted by our AI tool, the operators showed less variability between measurements with higher intraclass correlation coefficients (ICCs 0.999 95% CI 0.998–0.999 vs. 0.982 95% CI 0.962–0.993) and lower Bland Altman limits of agreement (± 1.9% vs. ± 6.6%) compared to not using the AI tool. The time spent on scans reduced significantly from a median of 19.6 min (IQR 16.9–21.7) to 9.4 min (IQR 7.2–11.7) compared to when using the AI tool (p < 0.001). AI-assisted muscle ultrasound removes the need for manual tracing, increases reproducibility and saves time. This system may aid monitoring muscle size in ICU patients assisting rehabilitation programmes.
first_indexed 2024-09-25T04:12:56Z
format Journal article
id oxford-uuid:e972e6b4-8d1d-4c3f-86f3-cae1328dbb71
institution University of Oxford
language English
last_indexed 2024-09-25T04:12:56Z
publishDate 2024
publisher Nature Research
record_format dspace
spelling oxford-uuid:e972e6b4-8d1d-4c3f-86f3-cae1328dbb712024-06-27T20:11:04ZClinical evaluation of AI-assisted muscle ultrasound for monitoring muscle wasting in ICU patientsJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:e972e6b4-8d1d-4c3f-86f3-cae1328dbb71EnglishJisc Publications RouterNature Research2024Nhat, PTHVan Hao, NYen, LMAnh, NHKhiem, DPKerdegari, HPhuong, LTHoang, VTNgoc, NTThu, LNMTrung, TNPisani, LRazavi, RYacoub, SVan Vinh Chau, NKing, APThwaites, LDenehy, LGomez, AMuscle ultrasound has been shown to be a valid and safe imaging modality to assess muscle wasting in critically ill patients in the intensive care unit (ICU). This typically involves manual delineation to measure the rectus femoris cross-sectional area (RFCSA), which is a subjective, time-consuming, and laborious task that requires significant expertise. We aimed to develop and evaluate an AI tool that performs automated recognition and measurement of RFCSA to support non-expert operators in measurement of the RFCSA using muscle ultrasound. Twenty patients were recruited between Feb 2023 and July 2023 and were randomized sequentially to operators using AI (n = 10) or non-AI (n = 10). Muscle loss during ICU stay was similar for both methods: 26 ± 15% for AI and 23 ± 11% for the non-AI, respectively (p = 0.13). In total 59 ultrasound examinations were carried out (30 without AI and 29 with AI). When assisted by our AI tool, the operators showed less variability between measurements with higher intraclass correlation coefficients (ICCs 0.999 95% CI 0.998–0.999 vs. 0.982 95% CI 0.962–0.993) and lower Bland Altman limits of agreement (± 1.9% vs. ± 6.6%) compared to not using the AI tool. The time spent on scans reduced significantly from a median of 19.6 min (IQR 16.9–21.7) to 9.4 min (IQR 7.2–11.7) compared to when using the AI tool (p < 0.001). AI-assisted muscle ultrasound removes the need for manual tracing, increases reproducibility and saves time. This system may aid monitoring muscle size in ICU patients assisting rehabilitation programmes.
spellingShingle Nhat, PTH
Van Hao, N
Yen, LM
Anh, NH
Khiem, DP
Kerdegari, H
Phuong, LT
Hoang, VT
Ngoc, NT
Thu, LNM
Trung, TN
Pisani, L
Razavi, R
Yacoub, S
Van Vinh Chau, N
King, AP
Thwaites, L
Denehy, L
Gomez, A
Clinical evaluation of AI-assisted muscle ultrasound for monitoring muscle wasting in ICU patients
title Clinical evaluation of AI-assisted muscle ultrasound for monitoring muscle wasting in ICU patients
title_full Clinical evaluation of AI-assisted muscle ultrasound for monitoring muscle wasting in ICU patients
title_fullStr Clinical evaluation of AI-assisted muscle ultrasound for monitoring muscle wasting in ICU patients
title_full_unstemmed Clinical evaluation of AI-assisted muscle ultrasound for monitoring muscle wasting in ICU patients
title_short Clinical evaluation of AI-assisted muscle ultrasound for monitoring muscle wasting in ICU patients
title_sort clinical evaluation of ai assisted muscle ultrasound for monitoring muscle wasting in icu patients
work_keys_str_mv AT nhatpth clinicalevaluationofaiassistedmuscleultrasoundformonitoringmusclewastinginicupatients
AT vanhaon clinicalevaluationofaiassistedmuscleultrasoundformonitoringmusclewastinginicupatients
AT yenlm clinicalevaluationofaiassistedmuscleultrasoundformonitoringmusclewastinginicupatients
AT anhnh clinicalevaluationofaiassistedmuscleultrasoundformonitoringmusclewastinginicupatients
AT khiemdp clinicalevaluationofaiassistedmuscleultrasoundformonitoringmusclewastinginicupatients
AT kerdegarih clinicalevaluationofaiassistedmuscleultrasoundformonitoringmusclewastinginicupatients
AT phuonglt clinicalevaluationofaiassistedmuscleultrasoundformonitoringmusclewastinginicupatients
AT hoangvt clinicalevaluationofaiassistedmuscleultrasoundformonitoringmusclewastinginicupatients
AT ngocnt clinicalevaluationofaiassistedmuscleultrasoundformonitoringmusclewastinginicupatients
AT thulnm clinicalevaluationofaiassistedmuscleultrasoundformonitoringmusclewastinginicupatients
AT trungtn clinicalevaluationofaiassistedmuscleultrasoundformonitoringmusclewastinginicupatients
AT pisanil clinicalevaluationofaiassistedmuscleultrasoundformonitoringmusclewastinginicupatients
AT razavir clinicalevaluationofaiassistedmuscleultrasoundformonitoringmusclewastinginicupatients
AT yacoubs clinicalevaluationofaiassistedmuscleultrasoundformonitoringmusclewastinginicupatients
AT vanvinhchaun clinicalevaluationofaiassistedmuscleultrasoundformonitoringmusclewastinginicupatients
AT kingap clinicalevaluationofaiassistedmuscleultrasoundformonitoringmusclewastinginicupatients
AT thwaitesl clinicalevaluationofaiassistedmuscleultrasoundformonitoringmusclewastinginicupatients
AT denehyl clinicalevaluationofaiassistedmuscleultrasoundformonitoringmusclewastinginicupatients
AT gomeza clinicalevaluationofaiassistedmuscleultrasoundformonitoringmusclewastinginicupatients