Towards a robust estimation of respiratory rate from pulse oximeters

<h4>Goal</h4> <p>Current methods for estimating respiratory rate (RR) from the photoplethysmogram (PPG) typically fail to distinguish between periods of high- and low-quality input data, and fail to perform well on independent “validation” datasets. The lack of robustness of exist...

Full description

Bibliographic Details
Main Authors: Pimentel, M, Johnson, A, Charlton, P, Birrenkott, D, Watkinson, P, Tarassenko, L, Clifton, D
Format: Journal article
Published: Institute of Electrical and Electronics Engineers 2016
_version_ 1797101632976060416
author Pimentel, M
Johnson, A
Charlton, P
Birrenkott, D
Watkinson, P
Tarassenko, L
Clifton, D
author_facet Pimentel, M
Johnson, A
Charlton, P
Birrenkott, D
Watkinson, P
Tarassenko, L
Clifton, D
author_sort Pimentel, M
collection OXFORD
description <h4>Goal</h4> <p>Current methods for estimating respiratory rate (RR) from the photoplethysmogram (PPG) typically fail to distinguish between periods of high- and low-quality input data, and fail to perform well on independent “validation” datasets. The lack of robustness of existing methods directly results in a lack of penetration of such systems into clinical practice. The present work proposes an alternative method to improve the robustness of the estimation of RR from the PPG.</p> <h4>Methods</h4> <p>The proposed algorithm is based on the use of multiple autoregressive models of different orders for determining the dominant respiratory frequency in the three respiratory-induced variations (frequency, amplitude and intensity) derived from the PPG. The algorithm was tested on two different datasets comprising 95 8-minute PPG recordings (in total) acquired from both children and adults in different clinical settings, and its performance using two window sizes (32 and 64 seconds) was compared with that of existing methods in the literature.</p> <h4>Results</h4> <p>The proposed method achieved comparable accuracy to existing methods in the literature, with mean absolute errors (median, 25th-75th percentiles for a window size of 32 seconds) of 1.5 (0.3-3.3) and 4.0 (1.8-5.5) breaths per minute (for each dataset respectively), whilst providing RR estimates for a greater proportion of windows (over 90% of the input data are kept). </p> <h4>Conclusion</h4> <p>Increased robustness of RR estimation by the proposed method was demonstrated. </p> <h4>Significance</h4> <p>This work demonstrates that the use of large publicly-available datasets is essential for improving the robustness of wearable-monitoring algorithms for use in clinical practice.</p>
first_indexed 2024-03-07T05:54:33Z
format Journal article
id oxford-uuid:ea142c22-5cda-42c6-a9c1-7954f508fb28
institution University of Oxford
last_indexed 2024-03-07T05:54:33Z
publishDate 2016
publisher Institute of Electrical and Electronics Engineers
record_format dspace
spelling oxford-uuid:ea142c22-5cda-42c6-a9c1-7954f508fb282022-03-27T10:59:02ZTowards a robust estimation of respiratory rate from pulse oximetersJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:ea142c22-5cda-42c6-a9c1-7954f508fb28Symplectic Elements at OxfordInstitute of Electrical and Electronics Engineers2016Pimentel, MJohnson, ACharlton, PBirrenkott, DWatkinson, PTarassenko, LClifton, D <h4>Goal</h4> <p>Current methods for estimating respiratory rate (RR) from the photoplethysmogram (PPG) typically fail to distinguish between periods of high- and low-quality input data, and fail to perform well on independent “validation” datasets. The lack of robustness of existing methods directly results in a lack of penetration of such systems into clinical practice. The present work proposes an alternative method to improve the robustness of the estimation of RR from the PPG.</p> <h4>Methods</h4> <p>The proposed algorithm is based on the use of multiple autoregressive models of different orders for determining the dominant respiratory frequency in the three respiratory-induced variations (frequency, amplitude and intensity) derived from the PPG. The algorithm was tested on two different datasets comprising 95 8-minute PPG recordings (in total) acquired from both children and adults in different clinical settings, and its performance using two window sizes (32 and 64 seconds) was compared with that of existing methods in the literature.</p> <h4>Results</h4> <p>The proposed method achieved comparable accuracy to existing methods in the literature, with mean absolute errors (median, 25th-75th percentiles for a window size of 32 seconds) of 1.5 (0.3-3.3) and 4.0 (1.8-5.5) breaths per minute (for each dataset respectively), whilst providing RR estimates for a greater proportion of windows (over 90% of the input data are kept). </p> <h4>Conclusion</h4> <p>Increased robustness of RR estimation by the proposed method was demonstrated. </p> <h4>Significance</h4> <p>This work demonstrates that the use of large publicly-available datasets is essential for improving the robustness of wearable-monitoring algorithms for use in clinical practice.</p>
spellingShingle Pimentel, M
Johnson, A
Charlton, P
Birrenkott, D
Watkinson, P
Tarassenko, L
Clifton, D
Towards a robust estimation of respiratory rate from pulse oximeters
title Towards a robust estimation of respiratory rate from pulse oximeters
title_full Towards a robust estimation of respiratory rate from pulse oximeters
title_fullStr Towards a robust estimation of respiratory rate from pulse oximeters
title_full_unstemmed Towards a robust estimation of respiratory rate from pulse oximeters
title_short Towards a robust estimation of respiratory rate from pulse oximeters
title_sort towards a robust estimation of respiratory rate from pulse oximeters
work_keys_str_mv AT pimentelm towardsarobustestimationofrespiratoryratefrompulseoximeters
AT johnsona towardsarobustestimationofrespiratoryratefrompulseoximeters
AT charltonp towardsarobustestimationofrespiratoryratefrompulseoximeters
AT birrenkottd towardsarobustestimationofrespiratoryratefrompulseoximeters
AT watkinsonp towardsarobustestimationofrespiratoryratefrompulseoximeters
AT tarassenkol towardsarobustestimationofrespiratoryratefrompulseoximeters
AT cliftond towardsarobustestimationofrespiratoryratefrompulseoximeters