Correction of slice misalignment in multi-breath-hold cardiac MRI scans

Cardiac Magnetic Resonance (CMR) provides unique functional and anatomical visualization of the macro and micro-structures of the heart. However, CMR acquisition times usually necessitate slices to be acquired at different breath holds, which results in potential misalignment of the acquired slices....

Full description

Bibliographic Details
Main Authors: Villard, B, Zacur, E, Dall'Armellina, E, Grau, V
Format: Conference item
Published: Springer 2017
Description
Summary:Cardiac Magnetic Resonance (CMR) provides unique functional and anatomical visualization of the macro and micro-structures of the heart. However, CMR acquisition times usually necessitate slices to be acquired at different breath holds, which results in potential misalignment of the acquired slices. Correcting for this spatial misalignment is required for accurate three-dimensional (3D) reconstruction of the heart chambers allowing robust metrics for shape analysis among populations as well as precise representations of individual geometries and scars. While several methods have been proposed to realign slices, their use in other important protocols such as Late Gadolinium Enhancement (LGE) is yet to be demonstrated. We propose a registration framework based on local phase to correct for slice misalignment. Our registration framework is a group registration technique combining long- and short-axis slices. Validation was performed on LGE slices using expert-traced ventricular contours. For 15 clinical multi-breath-hold datasets our method reduced the median discrepancy of moderately misaligned slices from 2.19 mm to 1.63 mm, and of severely misaligned from 7.33 mm to 1.96 mm.