Finline-integrated cold electron bolometer

The Cold-Electron Bolometer (CEB) is a sensitive millimetre-wave detector which is easy to integrate with superconducting planar circuits. CEB detectors have other important features such as high saturation power and very fast response. We have fabricated and tested CEB detectors integrated across t...

ver descrição completa

Detalhes bibliográficos
Principais autores: Otto, E, Tarasov, M, Grimes, P, Kaurova, N, Kuusisto, H, Kuzmin, L, Yassin, G
Formato: Conference item
Publicado em: 2010
_version_ 1826304057082380288
author Otto, E
Tarasov, M
Grimes, P
Kaurova, N
Kuusisto, H
Kuzmin, L
Yassin, G
author_facet Otto, E
Tarasov, M
Grimes, P
Kaurova, N
Kuusisto, H
Kuzmin, L
Yassin, G
author_sort Otto, E
collection OXFORD
description The Cold-Electron Bolometer (CEB) is a sensitive millimetre-wave detector which is easy to integrate with superconducting planar circuits. CEB detectors have other important features such as high saturation power and very fast response. We have fabricated and tested CEB detectors integrated across the slot of a unilateral finline on a silicon substrate. Bolometers were fabricated using two fabrication methods: e-beam direct-write trilayer technology and an advanced shadow mask evaporation technique. The CEB performance was tested in a He3 sorption cryostat at a bath temperature of 280mK. DC I-V curves and temperature responses were measured in a current bias mode, and preliminary measurements of the optical response were made using an IMPATT diode operating at 110GHz. These tests were conducted by coupling power directly into the finline chip, without the use of waveguide or feedhorns. For the devices fabricated in standard direct-write technology, the bolometer dark electrical noise equivalent power is estimated to be about 5×10-16W/ √Hz, while the dark NEP value for the shadow mask evaporation technique devices is estimated to be as low as 3×10-17W/√Hz. © 2010 SPIE.
first_indexed 2024-03-07T06:12:02Z
format Conference item
id oxford-uuid:efda5a9e-a0e6-4564-a558-1e5385b3feb0
institution University of Oxford
last_indexed 2024-03-07T06:12:02Z
publishDate 2010
record_format dspace
spelling oxford-uuid:efda5a9e-a0e6-4564-a558-1e5385b3feb02022-03-27T11:43:15ZFinline-integrated cold electron bolometerConference itemhttp://purl.org/coar/resource_type/c_5794uuid:efda5a9e-a0e6-4564-a558-1e5385b3feb0Symplectic Elements at Oxford2010Otto, ETarasov, MGrimes, PKaurova, NKuusisto, HKuzmin, LYassin, GThe Cold-Electron Bolometer (CEB) is a sensitive millimetre-wave detector which is easy to integrate with superconducting planar circuits. CEB detectors have other important features such as high saturation power and very fast response. We have fabricated and tested CEB detectors integrated across the slot of a unilateral finline on a silicon substrate. Bolometers were fabricated using two fabrication methods: e-beam direct-write trilayer technology and an advanced shadow mask evaporation technique. The CEB performance was tested in a He3 sorption cryostat at a bath temperature of 280mK. DC I-V curves and temperature responses were measured in a current bias mode, and preliminary measurements of the optical response were made using an IMPATT diode operating at 110GHz. These tests were conducted by coupling power directly into the finline chip, without the use of waveguide or feedhorns. For the devices fabricated in standard direct-write technology, the bolometer dark electrical noise equivalent power is estimated to be about 5×10-16W/ √Hz, while the dark NEP value for the shadow mask evaporation technique devices is estimated to be as low as 3×10-17W/√Hz. © 2010 SPIE.
spellingShingle Otto, E
Tarasov, M
Grimes, P
Kaurova, N
Kuusisto, H
Kuzmin, L
Yassin, G
Finline-integrated cold electron bolometer
title Finline-integrated cold electron bolometer
title_full Finline-integrated cold electron bolometer
title_fullStr Finline-integrated cold electron bolometer
title_full_unstemmed Finline-integrated cold electron bolometer
title_short Finline-integrated cold electron bolometer
title_sort finline integrated cold electron bolometer
work_keys_str_mv AT ottoe finlineintegratedcoldelectronbolometer
AT tarasovm finlineintegratedcoldelectronbolometer
AT grimesp finlineintegratedcoldelectronbolometer
AT kaurovan finlineintegratedcoldelectronbolometer
AT kuusistoh finlineintegratedcoldelectronbolometer
AT kuzminl finlineintegratedcoldelectronbolometer
AT yassing finlineintegratedcoldelectronbolometer